PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT
Report
- Report Number
- 2210968-2018-73773
- Event Type
- Injury
- Date Received
- June 25, 2018
- Report Date
- June 5, 2018
- Manufacturer
- ETHICON INC.
- Product Code
- GAW
- PMA / PMN Number
- K133356
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. NO SPECIFIC PATIENT INFORMATION REGARDING EVENTS HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. (B)(4).
TITLE: 2-0 PROLENE BROW SUSPENSION FOR PAEDIATRIC PTOSIS: A RETROSPECTIVE CASE SERIES OF 37 EYESTHE AIM OF THIS RETROSPECTIVE CASE REVIEW WAS TO ASSESS THE EFFICACY OF 2-0 PROLENE BROW SUSPENSION SURGERY IN PAEDIATRIC PTOSIS WITH POOR LEVATOR FUNCTION. BETWEEN 1997 AND 2007, 27 (37 EYES) PATIENTS (11 FEMALES AND 16 MALES) UNDER THE AGE OF 10 YEARS WHO UNDERWENT 2-0 PROLENE BROW SUSPENSIONS FOR CONGENITAL PTOSIS WERE INCLUDED IN THE STUDY. DURING THE PROCEDURE, A LID GUARD WAS PLACED ON THE PATIENT. WRIGHT¿S NEEDLE WAS USED TO THREAD THE 2-0 PROLENE SUTURE (WITH THE NEEDLE REMOVED) BELOW THE SUBCUTANEOUS TISSUE IN THE LID, IN A PLANE JUST SUPERFICIAL TO THE TARSAL PLATE AND IN THE BROW SUPERFICIAL TO THE FASCIAL PLANE. IN VERY SMALL CHILDREN THE SUTURE WAS THREADED ONTO A SURGICAL NEEDLE. PTOSIS RECURRED IN 10 EYELIDS OF WHICH 6 WENT ON TO HAVE FURTHER SURGERY IN THE FORM OF FASCIA LATA BROW SUSPENSION AND 4 HAD REPEAT 2-0 PROLENE BROW SUSPENSION. IN ONE EYELID THE PTOSIS RECURRED FOLLOWING LID TRAUMA (HITTING HEAD DURING A SEIZURE) AND NEEDED TO BE RE-ADJUSTED USING THE EXISTING PROLENE SUTURE. OF THE 4 CASES THAT HAD A SECOND 2-0 PROLENE PROCEDURE ALL CASES ACHIEVED FUNCTIONAL SUCCESS WITH A MEAN FOLLOW-UP OF 36.75 MONTHS. IN CONCLUSION, THE RESULTS FROM THIS SERIES INDICATE THAT IN MOST CASES A PROLENE BROW SUSPENSION PROVIDES A LONG TERM RESULT AND A SECOND PROCEDURE CAN BE COMPLETELY AVOIDED OR AT LEAST DELAYED UNTIL THE CHILD IS MUCH OLDER.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 475715 | PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT | SUTURE, NONABSORBABLE | GAW | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |