FDA Adverse Event Injury Summary report: N

SYNVISC ONE

MDR report key: 7584219 · Received June 8, 2018

Report

Report Number
2246315-2018-00478
Event Type
Injury
Date Received
June 8, 2018
Date of Event
November 10, 2017
Report Date
June 8, 2018
Manufacturer
GENZYME BIOSURGERY (RIDGEFIELD)
Product Code
MOZ
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
LA, US
Reporter Occupation
PHYSICIAN

Narratives

Description of Event or Problem · 1

DEVICE MALFUNCTION [DEVICE MALFUNCTION] , FLUID BUILDUP IN AND AROUND HER KNEES [KNEE EFFUSION], SWELLING OF HER KNEES [KNEE SWELLING] , EXPERIENCED ADVERSE EFFECTS FROM SYNVISC-ONE. [UNEVALUABLE EVENT] , CHILLS [CHILLS] , REDNESS [REDNESS] . CASE NARRATIVE: BASED ON THE INFORMATION RECEIVED ON (B)(6) 2018 FROM PHYSICIAN, THIS CASE IS INITIALLY CONSIDERED AS NON-SERIOUS IS NOW UPDATED TO SERIOUS AS SERIOUS EVENTS DEVICE MALFUNCTION, FLUID BUILDUP IN AND AROUND HER KNEES WERE ADDED. ADDITIONALLY, THIS CASE HAS BECOME MEDICALLY CONFIRMED. THIS UNSOLICITED CASE FROM UNITED STATES WAS RECEIVED ON (B)(6) 2018 FROM OTHER NON-HEALTH CARE PROFESSIONAL THIS CASE CONCERNS A (B)(6) FEMALE PATIENT WHO INITIATED TREATMENT WITH SYNVISC ONE AND AFTER UNKNOWN LATENCY PATIENT EXPERIENCED ADVERSE EFFECTS FROM SYNVISC-ONE, SWELLING OF HER KNEES (LATENCY: 1 DAY), FLUID BUILDUP IN AND AROUND HER KNEES (LATENCY: 1 DAY/), CHILLS (LATENCY: 1 DAY) AND REDNESS (LATENCY: 1 DAY), SWELLING OF HER KNEES (LATENCY: 1 DAY) AND ALSO, DEVICE MALFUNCTION WAS IDENTIFIED FOR THE REPORTED LOT NUMBER. CONCOMITANT MEDICATIONS INCLUDED ASCORBIC ACID (VITAMIN C), ASPIRIN, FENOFIBRATE MICRONIZED (LOFIBRA) FOR TRIGLYCERIDES, IBUPROFEN (ADVIL, MOTRIN), LEVOTHYROXINE (SYNTHROID), MULTIVITAMIN (THERAGRAN), POTASSIUM CHLORIDE SA (K-DUR, KLOR-CON), ATORVASTATIN (LIPITOR) FOR CHOLESTEROL, BENAZEPRIL-HYDROCHLORTHIAZIDE (LOTENSIN HCT), LEVOTHYROXINE (SYNTHROID), OXYBUTYNIN (DITROPAN-XL), DICLOFENAC SODIUM 1% GEL. PATIENT HAD A MEDICAL HISTORY OF CATARACT, HYPERLIPIDEMIA, HYPERTENSION, HYPOTHYROID. PATIENT HAD A SURGICAL HISTORY OF APPENDECTOMY, BREAST BIOPSY (LEFT), BREAST LUMPECTOMY (LEFT), EYE SURGERY (CATARACT REMOVAL), HYSTERECTOMY, KNEE SURGERY (BILATERAL); (B)(6) 2015; STEM CELL COMPLETED), THYROID LOBECTOMY, TONSILLECTOMY, CHRONIC PAIN OF LEFT KNEE, CHRONIC PAIN OF RIGHT KNEE, DIFFICULTY WALKING, RENAL INSUFFICIENCY, GASTROENTERITIS, EXPLORATORY LAPAROTOMY FOR RIGHT OVARIAN TERATOMA, IMPAIRED FASTING GLUCOSE, OBESITY, COLONIC POLYPS. PATIENT IS A SMOKER (THE PATIENT SMOKED 0.25 PACKS/DAY FOR 50 YEARS) AND PATIENT NEVER USED SMOKELESS TOBACCO. PATIENT USES ALCOHOL (TAKE 1.8 OZ TOTAL ALCOHOL PER WEEK; 1 GLASSES OF WINE, 1 CANS OF BEER, 1 SHOTS OF LIQUOR). PATIENT USES NO DRUGS. PATIENT HAS A FAMILY HISTORY OF BREAST CANCER (MATERNAL AUNT), HYPERTENSION (MOTHER). PATIENT HAD ALLERGY TO IODINATED CONTRAST (RASH), ALLERGY TO IBUPROFEN (LTCH), ALLERGY TO NSAIDS (NON-STEROIDAL), PENICILLIN ALLERGY (LTCH). ON (B)(6) 2017 AT 12:57 PM, PATIENT RECEIVED TREATMENT WITH INTRA ARTICULAR SYNVISC ONE INJECTION AT A DOS OF 6 ML ONCE (BATCH/LOT NUMBER: 7RSL021; EXPIRATION DATE: 31-MAY-2020). FOR PRIMARY OSTEOARTHRITIS OF BOTH KNEES IN THE BOTH LEFT AND RIGHT KNEE. ON (B)(6) 2017 (AFTER 1 DAY OF RECEIVING SYNVISC ONE), THE PATIENT EXPERIENCED SWELLING OF HER KNEES, FLUID BUILDUP IN AN AROUND HER KNEES, CHILLS, AND REDNESS. ON AN UNKNOWN DATE, LATENCY UNKNOWN, PATIENT EXPERIENCED ADVERSE EFFECTS FROM SYNVISC ONE. CORRECTIVE TREATMENT: TRIAMCINOLONE ACETONIDE INJECTION FOR FLUID BUILDUP IN AND AROUND HER KNEES, SWELLING OF HER KNEES; NOT REPORTED FOR REST OF THE EVENTS. OUTCOME: UNKNOWN FOR EXPERIENCED ADVERSE EFFECTS FROM SYNVISC ONE; RECOVERED FOR OTHER EVENTS SERIOUSNESS CRITERIA: REQUIRED INTERVENTION FOR FLUID BUILDUP IN AND AROUND HER KNEES, SWELLING OF HER KNEES, DEVICE MALFUNCTION A PHARMACEUTICAL TECHNICAL COMPLAINT (PTC) WAS INITIATED WITH GLOBAL PTC NUMBER: (B)(4). AN INVESTIGATION WAS INITIATED AS A RESULT OF AN UNEXPECTED INCREASE IN THE NUMBER OF LABELLED ADVERSE EVENTS RECEIVED FROM THE US MARKET FOR SYNVISC ONE, LOT 7RSL021. THE PRODUCT MET ALL RELEASE TESTING AT TIME OF MANUFACTURE IN JUNE 2017. RETAIN SAMPLES WERE RETESTED DUE TO THE UNEXPECTED INCREASE IN ADVERSE EVENTS. HIGHER THAN EXPECTED ENDOTOXIN RESULTS WERE OBTAINED. IN ADDITION, THE PRESENCE OF MICROBIAL CONTAMINATION WAS ALSO CONFIRMED. THE CAUSE OF THESE EVENTS WAS UNDER INVESTIGATION. ONCE THIS INVESTIGATION IS COMPLETED, CORRECTIVE AND PREVENTIVE ACTIONS WOULD BE IMPLEMENTED. ADDITIONAL INFORMATION WAS RECEIVED ON 06-MAR-2018: GLOBAL PTC NUMBER AND RESULTS WERE ADDED. ADDITIONAL INFORMATION WAS RECEIVED ON 07-MAY-2018 FROM PHYSICIAN. AGE OF PATIENT WAS ADDED. SYNVISC ONE DOSE, FREQUENCY, INDICATION, BATCH/LOT NUMBER (7RSL021) AND EXPIRATION NUMBER WAS ADDED. EVENT DEVICE MALFUNCTION, FLUID BUILDUP IN AND AROUND HER KNEES, CHILLS AND REDNESS WAS ADDED. MEDICAL HISTORY, FAMILY HISTORY, PERSONAL HISTORY, DRUG ALLERGIES AND CONCOMITANT MEDICATION WERE ADDED. CLINICAL COURSE WAS UPDATED. TEXT WAS AMENDED ACCORDINGLY. FOLLOW-UP WAS RECEIVED ON 10-MAY-2018. NO NEW INFORMATION WAS RECEIVED. FOLLOW-UP INFORMATION WAS RECEIVED ON 15-MAY-2018. NO NEW INFORMATION WAS RECEIVED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
424596 SYNVISC ONE MOZ MOZ GENZYME BIOSURGERY (RIDGEFIELD) UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1 79 YR Required Intervention