BD VACUTAINER® 9NC 0.109M PLUS BLOOD COLLECTION TUBES
Report
- Report Number
- 9617032-2018-02065
- Event Type
- Malfunction
- Date Received
- June 6, 2018
- Date of Event
- March 9, 2018
- Report Date
- May 10, 2018
- Manufacturer
- BECTON, DICKINSON AND COMPANY (BD)
- Product Code
- JKA
- UDI-DI
- 50382903630955
- PMA / PMN Number
- N/A
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- UK
- Reporter Occupation
- OTHER
Narratives
MULTIPLE LOT NUMBERS: THERE WERE MULTIPLE LOT NUMBERS REPORTED TO BE INVOLVED. THE INFORMATION FOR EACH LOT NUMBER IS AS FOLLOWS: MEDICAL DEVICE LOT #: 8024693, MEDICAL DEVICE EXPIRATION DATE: 2018-10-31, DEVICE MANUFACTURE DATE: 2018-01-24. MEDICAL DEVICE LOT #: 7233747, MEDICAL DEVICE EXPIRATION DATE: 2018-05-31, DEVICE MANUFACTURE DATE: 2017-08-21. MEDICAL DEVICE LOT #: 7150932, MEDICAL DEVICE EXPIRATION DATE: 2018-02-28, DEVICE MANUFACTURE DATE: 2017-05-30. MEDICAL DEVICE LOT #: 7244908, MEDICAL DEVICE EXPIRATION DATE: 2018-05-31, DEVICE MANUFACTURE DATE: 2017-09-01. MEDICAL DEVICE LOT #: 7275817, MEDICAL DEVICE EXPIRATION DATE: 2018-06-30, DEVICE MANUFACTURE DATE: 2017-10-02. MEDICAL DEVICE LOT #: 7276631, MEDICAL DEVICE EXPIRATION DATE: 2018-07-31, DEVICE MANUFACTURE DATE: 2017-10-03. MEDICAL DEVICE LOT #: 6228762, MEDICAL DEVICE EXPIRATION DATE: 2017-05-31, DEVICE MANUFACTURE DATE: 2016-08-15. MEDICAL DEVICE LOT #: UNKNOWN, MEDICAL DEVICE EXPIRATION DATE: UNKNOWN, DEVICE MANUFACTURE DATE: UNKNOWN. (B)(6). INVESTIGATION SUMMARY: BD RECEIVED SAMPLES AND PHOTOS FROM THE CUSTOMER FACILITY FOR INVESTIGATION. THE PHOTOS WERE EVALUATED AND THE CUSTOMER¿S INDICATED FAILURE MODE FOR UNDERFILL WITH THE INCIDENT LOT WAS OBSERVED. ADDITIONALLY, EVALUATION/TESTING OF THE CUSTOMER SAMPLES WAS PERFORMED AND UNDERFILL WAS NOT OBSERVED. A REVIEW OF THE MANUFACTURING RECORDS WAS COMPLETED FOR THE INCIDENT LOT AND NO ISSUES WERE IDENTIFIED. BD HAS INITIATED FURTHER INVESTIGATION RELATING TO THIS ISSUE THROUGH A CAPA. THE INVESTIGATION IS STILL ON-GOING AND IMPROVEMENTS WILL BE MADE AS THE POTENTIAL CAUSES OF THIS ISSUE ARE IDENTIFIED. INVESTIGATION CONCLUSION: BASED ON EVALUATION OF THE CUSTOMER PHOTOS, THE CUSTOMER¿S INDICATED FAILURE MODE FOR UNDERFILL WITH THE INCIDENT LOT WAS OBSERVED. ADDITIONALLY, EVALUATION/TESTING OF THE CUSTOMER SAMPLES WAS CONDUCTED AND UNDERFILL WAS NOT OBSERVED. FURTHER INVESTIGATION HAS BEEN INITIATED THROUGH A CAPA. THE INVESTIGATION IS STILL ON-GOING AND IMPROVEMENTS WILL BE MADE AS THE POTENTIAL CAUSES ARE IDENTIFIED. ROOT CAUSE DESCRIPTION: A CAPA HAS BEEN INITIATED TO DOCUMENT FURTHER INVESTIGATION AND ROOT CAUSE ANALYSIS RELATING TO THIS ISSUE. THE INVESTIGATION IS CURRENTLY ON-GOING AND WILL BE UPDATED AS THE POTENTIAL ROOT CAUSE(S) ARE IDENTIFIED. RATIONALE: BASED ON AN ASSESSMENT OF SEVERITY AND FREQUENCY, IT WAS DETERMINED THAT A CAPA IS REQUIRED AT THIS TIME IN ORDER TO DETERMINE THE ROOT CAUSE ASSOCIATED WITH THIS ISSUE AND IMPLEMENT CORRECTIVE ACTIONS. THE INVESTIGATION IS CURRENTLY ON-GOING AND FURTHER IMPROVEMENTS WILL BE MADE AS THE POTENTIAL ROOT CAUSE(S) ARE IDENTIFIED.
IT WAS REPORTED THAT BD VACUTAINER® 9NC 0.109M PLUS BLOOD COLLECTION TUBES WERE UNDERFILLED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 417883 | BD VACUTAINER® 9NC 0.109M PLUS BLOOD COLLECTION TUBES | BLOOD SPECIMEN COLLECTION DEVICE | JKA | BECTON, DICKINSON AND COMPANY (BD) | 7296739 | 50382903630955 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |