STENT - VASCULAR RECONSTRUCTION
Report
- Report Number
- 1226348-2018-00593
- Event Type
- Injury
- Date Received
- May 11, 2018
- Date of Event
- March 20, 2013
- Report Date
- April 19, 2018
- Manufacturer
- CODMAN AND SHURTLEFF, INC
- Product Code
- NJE
- PMA / PMN Number
- H60001
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CH
- Reporter Occupation
- HEALTH PROFESSIONAL
Narratives
(B)(4). THE LITERATURE ARTICLE WAS FOUND DURING A RECENT POST-MARKET SURVEILLANCE REVIEW (PMS) OF THIS DEVICE. THE CITATION IS AS FOLLOW: WORLD NEUROSURG. (2016) 91: 218-227. HTTP://DX.DOI.ORG/10.1016/J.WNEU.2016.04.024 ¿MAGNETIC RESONANCE IMAGING FOLLOW-UP OF LARGE OR GIANT VERTEBROBASILAR DISSECTING ANEURYSMS AFTER TOTAL EMBOLIZATION ON ANGIOGRAPHY.¿ DUE TO THE NATURE OF THE COMPLAINT, THE DEVICE WAS NOT RETURNED FOR ANALYSIS NOR WAS THE STERILE LOT NUMBER PROVIDED IN ORDER TO CONDUCT A LOT HISTORY REVIEW. THIS IS ONE OF 3 PRODUCTS INVOLVED WITH THE REPORTED COMPLAINT. THE ASSOCIATED MANUFACTURER REPORT NUMBERS ARE: 1226348-2018-00557 AND 1226348-2018-00592. (B)(6). [COMPLAINT CONCLUSION]: THE EVENT WAS CAPTURED IN THE LITERATURE PUBLICATION WORLD NEUROSURG. (2016) 91: 218-227. HTTP://DX.DOI.ORG/10.1016/J.WNEU.2016.04.024 ¿MAGNETIC RESONANCE IMAGING FOLLOW-UP OF LARGE OR GIANT VERTEBROBASILAR DISSECTING ANEURYSMS AFTER TOTAL EMBOLIZATION ON ANGIOGRAPHY.¿ IT WAS REPORTED THAT A (B)(6)-YEAR OLD MALE PATIENT FROM ¿CASE 2¿ IN THIS STUDY WHO HAD A RECURRENT VERTEBRAL ARTERY DISSECTING ANEURYSM COMPLAINED OF HEADACHE, UPPER-LIMB NUMBNESS, UNSTABLE GAIT, DIFFICULT EXPECTORATION, AND RECURRENT PULMONARY INFECTION FOR 2 YEARS WAS ADMITTED TO THE STUDY INSTITUTION (DEPARTMENT OF NEUROSURGERY, (B)(6) HOSPITAL OF (B)(6) UNIVERSITY) ON (B)(6) 2013. INITIAL HIGH-RESOLUTION MAGNETIC RESONANCE IMAGING (MRI) OF THE ARTERIAL WALL TAKEN 4 MONTHS EARLIER DEMONSTRATED A DISSECTING ANEURYSM ON THE V4 SEGMENT OF THE RIGHT VERTEBRAL ARTERY. THE PATIENT UNDERWENT RECONSTRUCTIVE ENDOVASCULAR REPAIR WITH 3 OVERLAPPED 4.5 X 28 MM ENTERPRISE STENTS AND COILS AT THE INITIAL DIAGNOSIS. THE PATIENT¿S SYMPTOMS DID NOT IMPROVE, HE REPORTED EXPERIENCING DYSPNEA AND REQUIRED EMERGENCY TREATMENT 4 MONTHS AFTER THE FIRST PROCEDURE. ON (B)(6) 2013, THE PATIENT UNDERWENT THE INTERNAL TRAPPING WITH COILS PROCEDURE. THE PATIENT¿S RECOVERY WAS SLOW AFTER THE SECOND PROCEDURE DUE TO RECURRENT PNEUMONIA; AS A RESULT, INTERMITTENT MECHANICAL VENTILATION WAS PROVIDED TO THE PATIENT FOR APPROXIMATELY 1 YEAR. THE PATIENT GRADUALLY RECOVERED AND EVENTUALLY COULD WALK AGAIN 1 YEAR AFTER UNDERGOING THE SECOND PROCEDURE, BUT HIS UPPER EXTREMITY NUMBNESS AND THE UNSTABLE GAIT WORSENED. THE PATIENT ALSO EXHIBITED DIFFICULTY SWALLOWING LIQUIDS AND HAD LOWER LIMB WEAKNESS 26 MONTHS AFTER THE SECOND PROCEDURE. HIGH-RESOLUTION MRI AT FOLLOW-UP SHOWED PERSISTENT HEMORRHAGIC SIGNALS IN THE DISSECTING WALL AND ENLARGEMENT OF THE INTRAMURAL HEMATOMA (IMH). THE PATIENT¿S SYMPTOMS DID NOT IMPROVE WITH THE CONSERVATIVE THERAPY ELECTED. THERE WAS NO DEVICE SPECIFIC INFORMATION (INCLUDING DEVICE CATALOG AND LOT NUMBER) PROVIDED IN THE ARTICLE. THE OBJECTIVE OF THE STUDY WAS TO EVALUATE THE OUTCOMES OF LARGE OR GIANT VERTEBROBASILAR DISSECTING ANEURYSMS (VBDAS) AFTER ENDOVASCULAR TOTAL EMBOLIZATION BY FOLLOW-UP 3T (TESLA) HIGH-RESOLUTION MRI. THE STUDY RETROSPECTIVELY ANALYZED AND EVALUATED 4 PATIENTS WHO HAD UNRUPTURED LARGE OR GIANT VBDAS THAT WERE TREATED WITH ENDOVASCULAR TECHNIQUES WITH TOTAL EMBOLIZATION OF THE ANEURYSMS BETWEEN (B)(6) 2011 AND (B)(6) 2015, CONFIRMED ON FOLLOW-UP ANGIOGRAPHY, BUT HAD UNRELIEVED OR WORSENED SYMPTOMS. THE 3T HIGH-RESOLUTION MRS IMAGES OF BEFORE AND AFTER TREATMENT WERE EVALUATED TO ASSESS ARTERIAL WALL EVOLUTION. PATIENTS MEDICATION WAS DETERMINED DEPENDING ON THE ENDOVASCULAR PROCEDURE PERFORMED. IF RECONSTRUCTIVE ENDOVASCULAR PROCEDURES WERE CHOSEN, THE PATIENT WAS PRE-MEDICATED WITH A DUAL ANTIPLATELET REGIMEN OF 75 MG CLOPIDOGREL AND 100 MG ASPIRIN DAILY FOR 5 DAYS BEFORE THE TREATMENT PROCEDURE THEN RECEIVED THE STENT-ASSISTED COILING OR PLACEMENT OF A STENT WITHOUT COILS. BOTH THE DISSECTING ANEURYSM AND THE PARENT ARTERY WERE OCCLUDED WITH COILS IF THE INTERNAL TRAPPING TECHNIQUE WAS CHOSEN. DIGITAL SUBTRACTION ANGIOGRAPHY (DSA) AND MAGNETIC RESONANCE ANGIOGRAPHY (MRA) WERE USED TO ANALYZE LUMEN EVOLUTION. MRI OR HIGH-RESOLUTION MRI OF BEFORE AND AFTER TREATMENT WAS USED TO ANALYZE VESSEL WALL EVOLUTION. HETEROGENOUS SIGNAL INTENSITIES IN THE ANEURYSM WALL AND THE ¿ONION SKIN-LIKE¿ ASPECT OF THE ANEURYSM WITH THICKENING WALL SUGGEST THE PRESENCE OF A PARTIALLY THROMBOSED IMH AT DIFFERENT STAGES OF EVOLUTION. DURING FOLLOW-UP, THE PRESENCE OF AN INCREASED DIAMETER OF THE DISSECTING ANEURYSM WAS NOTED AND COMPARED WITH THE DIAMETER OF THE ANEURYSM BEFORE THE ENDOVASCULAR PROCEDURE. LESION ENHANCEMENT PATTERNS WERE ANALYZED IF GADOLINIUM WAS USED. RESULTS OF ARTERY LUMEN ASSESSMENT BY ANGIOGRAPHY SHOWED THAT ALL 4 PATIENTS SHOWED RELATIVELY SATISFACTORY RESULTS DURING FOLLOW-UP. THE (B)(6)-YEAR OLD MALE PATIENT IN ¿CASE 2¿ TREATED BY INTERNAL TRAPPING WITH COILS AT 26 MONTHS FOLLOW-UP SHOWED THAT ANEURYSM AND DISSECTING ARTERIES WERE COMPLETELY OCCLUDED. THE RESULT OF ARTERIAL WALL ASSESSMENT BY HIGH-RESOLUTION MRI FOR THE PATIENT IN ¿CASE 2¿ AT 26 MONTHS SHOWED AN ENLARGED ANEURYSM AND PERSISTENT HEMORRHAGIC SIGNALS AT THE PERIPHERY OF THE THROMBOSED ANEURYSM. LUMINAL RECONSTRUCTION OR OCCLUSION HAVE BEEN THE FOCUS OF MOST REPORTS FOLLOWING PROCEDURES. HOWEVER, IT IS NOT KNOWN WHETHER ARTERIAL WALL REMAINS STABLE, RECOVERS, OR BECAME PROGRESSIVELY WORSEN AFTER SUCCESSFUL ENDOVASCULAR TREATMENT. THE 4 CASES IN THIS STUDY HAD FOLLOW-UP ANGIOGRAPHY THAT CONFIRMED SATISFACTORY LUMINAL RESULTS, BUT FOLLOW-UP WITH HIGH-RESOLUTION MRI SHOWED NEW HEMATOMA OR PERSISTENT EXISTENCE OF HEMORRHAGIC SIGNALS IN THE DISSECTING WALL AND IN 3 OF THE 4 CASES ¿ INCREASED ANEURYSM SIZE. THE RESULTS CAPTURE A DISCREPANCY BETWEEN THE ARTERIAL WALL AND THE LUMEN AFTER ENDOVASCULAR TREATMENT THAT MIGHT BE A REASON TO RE-EVALUATE THE EFFICACY OF THE TREATMENT FOR THESE LESIONS. THE FORMATION OF AN IMH IS A CRITICAL EVENT NECESSARY FOR A DISSECTING ANEURYSM TO PROGRESS; THIS CAN BE MONITORED ON MRI. RECURRENT IMH CAN CAUSE DISSECTING ANEURYSMS TO GROW OR RUPTURE, BUT THE MECHANISM IS UNCLEAR. ONE OF THE HYPOTHESES APPLICABLE TO THE PATIENT IN ¿CASE 2¿ WHERE THE ANEURYSM CONTINUED TO GROW DUE TO THE PERSISTENT IMH EVEN AFTER THEIR PARENT VESSELS HAVE BEEN SACRIFICED IS THE RUPTURE OF THE VASA VASORUM IN THE ANEURYSM WALL. WHEN A SUFFICIENT LEVEL OF INTIMAL THICKENING IS REACHED, THAT PREVENT FURTHER MEDIAL DISSECTION AND NEOVASCULARIZATION BEGINS WITHIN THE THICKENED INTIMAE. NEW VESSELS IN THE INTIMAE APPEAR TO BE FRAGILE AND RESULT IN REPETITIVE IMH, WHICH IN TURN LEADS TO CHRONICALLY ENLARGING ANEURYSMS. INTERNAL TRAPPING WITH COILS HAS BEEN PROVEN TO BE A STABLE AND DURABLE TREATMENT FOR CLOSURE OF VBDAS, BUT IT REQUIRES ADEQUATE COLLATERAL FLOW AND INVOLVEMENT OF AN IMPORTANT PERFORATING BRANCH ARTERY IS A CONTRAINDICATION. THE DISSECTING ARTERY IN THE PATIENT IN ¿CASE 2¿ WAS COMPLETELY OCCLUDED AFTER UNDERGOING INTERNAL TRAPPING WITH COILS, BUT THE PATIENT HAD AN INCREASED IN ANEURYSM SIZE AND WORSEN SYMPTOMS AT FOLLOW-UP. THE PATIENT IN ¿CASE 2¿ WAS INITIALLY TREATED WITH STENT-ASSISTED COILING, WHICH IS WIDELY USED IN THE TREATMENT OF VBDAS, HOWEVER, FOR LARGE OR GIANT VBDAS, THE RECURRENCE RATE OF STENT-ASSISTED COILING IS RELATIVELY HIGH. AS A RESULT, THE PATIENT HAD RECANALIZATION AND UNDERWENT INTERNAL TRAPPING WITH COILS; THE PATIENT MIGHT HAVE HAD A FAVORABLE OUTCOME IF THE INITIAL PROCEDURE WAS INTERNAL TRAPPING WITH COILS. THE RARITY OF LARGE OR GIANT VBDAS IS THE LIMITATION OF THIS STUDY AS IT RESULTED IN ONLY 4 CASES ANALYZED. A PROSPECTIVE, MULTICENTER INVESTIGATION WITH A LARGE SAMPLE SIZE IS WARRANTED. THE STUDY CONCLUDED THAT THE EFFICACY OF CONVENTIONAL ENDOVASCULAR TREATMENT FOR LARGE OR GIANT VBDAS IS UNCERTAIN. ANGIOGRAPHY-ONLY AT FOLLOW-UP DOES NOT PROVIDE ADEQUATE PREDICTION OF OUTCOME. A WORTHWHILE ADJUNCT TO FOLLOW THESE LESIONS IS HIGH-RESOLUTION MRI. NEUROLOGICAL DEFICIT IS A KNOWN POTENTIAL COMPLICATION ASSOCIATED WITH THE ENTERPRISE VRD AND STENT-ASSISTED COIL EMBOLIZATION PROCEDURES. THE PUBLICATION STATES THAT PATIENTS WITH LARGE OR GIANT VBDAS ARE CLINICALLY CHALLENGING. THE NATURAL HISTORY IS POOR, ESPECIALLY WHEN THE ANEURYSM IS SYMPTOMATIC BY MASS EFFECT. DISSECTING ANEURYSMS MAY CONTINUE TO GROW BECAUSE OF THE PERSISTENT IMH EVEN AFTER THEIR PARENT VESSELS HAVE BEEN SACRIFICED. ANOTHER HYPOTHESIS FOR RECURRENT IMH IS RUPTURE OF THE VASA VASORUM IN THE ANEURYSM WALL. WHEN INTIMAL THICKENING REACHES A SUFFICIENT LEVEL TO PREVENT FURTHER MEDIAL DISSECTION, NEOVASCULARIZATION BEGINS WITHIN THE THICKENED INTIMAE. THE NEW VESSELS WITHIN THE INTIMAE APPEAR TO BE FRAGILE AND CAUSE REPETITIVE IMH, WHICH LEADS TO CHRONICALLY ENLARGING ANEURYSMS. THIS HYPOTHESIS CAN EXPLAIN WHY CONTINUOUS IMH WAS PRESENT IN THIS CASE. DESPITE ENDOVASCULAR TREATMENT, THE ANEURYSM ENLARGED AND SYMPTOMS WORSENED. AS OUTLINED IN THE IFU, THE INDICATED USE OF THE ENTERPRISE VRD IS TO PREVENT COILS FROM PROTRUDING OUT OF THE ANEURYSM INTO THE PARENT ARTERY. IN ADDITION, IT PRECAUTIONS THAT THE PERFORMANCE AND SAFETY OF TWO OR MORE OVERLAPPED STENTS HAS NOT BEEN ESTABLISHED. THE ROOT CAUSE CANNOT BE DETERMINED; HOWEVER, IT IS POSSIBLE THAT PROCEDURAL FACTORS AND THE COMPLEX NATURE OF THE PATIENT¿S UNDERLYING DISEASE MAY HAVE CONTRIBUTED TO THE EVENT. THE NEUROLOGICAL DEFICIT IS SERIOUS/LIFE-THREATENING, REQUIRED CONSERVATIVE TREATMENT, AND THE RELATIONSHIP OF THE EVENT TO THE DEVICE OR PROCEDURE CANNOT BE EXCLUDED. THUS, THE EVENT MEETS THE CRITERIA FOR MDR REPORTING AS A SERIOUS INJURY. THE FILE WILL BE RE-REVIEWED IF ADDITIONAL INFORMATION IS RECEIVED AT A LATER DATE. THE MANUFACTURER WILL SUBMIT A SUPPLEMENTAL REPORT IF NEW FACTS ARISE WHICH MATERIALLY ALTER INFORMATION SUBMITTED IN A PREVIOUS MDR REPORT. [(B)(4)].
THE EVENT WAS CAPTURED IN THE LITERATURE PUBLICATION WORLD NEUROSURG. (2016) 91: 218-227. HTTP://DX.DOI.ORG/10.1016/J.WNEU.2016.04.024 ¿MAGNETIC RESONANCE IMAGING FOLLOW-UP OF LARGE OR GIANT VERTEBROBASILAR DISSECTING ANEURYSMS AFTER TOTAL EMBOLIZATION ON ANGIOGRAPHY.¿ IT WAS REPORTED THAT A (B)(6)-YEAR OLD MALE PATIENT FROM ¿CASE 2¿ IN THIS STUDY WHO HAD A RECURRENT VERTEBRAL ARTERY DISSECTING ANEURYSM COMPLAINED OF HEADACHE, UPPER-LIMB NUMBNESS, UNSTABLE GAIT, DIFFICULT EXPECTORATION, AND RECURRENT PULMONARY INFECTION FOR 2 YEARS WAS ADMITTED TO THE STUDY INSTITUTION (DEPARTMENT OF NEUROSURGERY, (B)(6) HOSPITAL OF (B)(6) UNIVERSITY) ON (B)(6) 2013. INITIAL HIGH-RESOLUTION MAGNETIC RESONANCE IMAGING (MRI) OF THE ARTERIAL WALL TAKEN 4 MONTHS EARLIER DEMONSTRATED A DISSECTING ANEURYSM ON THE V4 SEGMENT OF THE RIGHT VERTEBRAL ARTERY. THE PATIENT UNDERWENT RECONSTRUCTIVE ENDOVASCULAR REPAIR WITH 3 OVERLAPPED 4.5 X 28 MM ENTERPRISE STENTS AND COILS AT THE INITIAL DIAGNOSIS. THE PATIENT¿S SYMPTOMS DID NOT IMPROVE, HE REPORTED EXPERIENCING DYSPNEA AND REQUIRED EMERGENCY TREATMENT 4 MONTHS AFTER THE FIRST PROCEDURE. ON (B)(6) 2013, THE PATIENT UNDERWENT THE INTERNAL TRAPPING WITH COILS PROCEDURE. THE PATIENT¿S RECOVERY WAS SLOW AFTER THE SECOND PROCEDURE DUE TO RECURRENT PNEUMONIA; AS A RESULT, INTERMITTENT MECHANICAL VENTILATION WAS PROVIDED TO THE PATIENT FOR APPROXIMATELY 1 YEAR. THE PATIENT GRADUALLY RECOVERED AND EVENTUALLY COULD WALK AGAIN 1 YEAR AFTER UNDERGOING THE SECOND PROCEDURE, BUT HIS UPPER EXTREMITY NUMBNESS AND THE UNSTABLE GAIT WORSENED. THE PATIENT ALSO EXHIBITED DIFFICULTY SWALLOWING LIQUIDS AND HAD LOWER LIMB WEAKNESS 26 MONTHS AFTER THE SECOND PROCEDURE. HIGH-RESOLUTION MRI AT FOLLOW-UP SHOWED PERSISTENT HEMORRHAGIC SIGNALS IN THE DISSECTING WALL AND ENLARGEMENT OF THE INTRAMURAL HEMATOMA (IMH). THE PATIENT¿S SYMPTOMS DID NOT IMPROVE WITH THE CONSERVATIVE THERAPY ELECTED. THERE WAS NO DEVICE SPECIFIC INFORMATION (INCLUDING DEVICE CATALOG AND LOT NUMBER) PROVIDED IN THE ARTICLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 349751 | STENT - VASCULAR RECONSTRUCTION | INTRACRANIAL NEUROVASCULAR STENT | NJE | CODMAN AND SHURTLEFF, INC |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 55 YR |