FDA Adverse Event Injury Summary report: N

BIPOLAR FORCEPS, UNSPECIFIED

MDR report key: 7507301 · Received May 11, 2018

Report

Report Number
2523190-2018-00069
Event Type
Injury
Date Received
May 11, 2018
Report Date
April 20, 2018
Manufacturer
INTEGRA MICROFRANCE S.A.S.
Product Code
GEI
PMA / PMN Number
K993655
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Occupation
DENTAL HYGIENIST

Narratives

Additional Manufacturer Narrative · 0

THE PRODUCT WAS NOT RETURNED FOR EVALUATION. THE LOT NUMBER WAS UNAVAILABLE, HENCE THE APPLICABLE DEVICE HISTORY RECORD COULD NOT BE REVIEWED. THE COMPLAINT IS NOT CONFIRMED. AN INVESTIGATION FOR CAUSE WAS UNABLE TO BE PERFORMED.

Additional Manufacturer Narrative · 1

IT IS UNKNOWN IF THE DEVICE INVOLVED IN THE REPORTED INCIDENTS IS EXPECTED TO BE RETURNED FOR EVALUATION. THE PLANT INVESTIGATION IS IN PROGRESS AND A SUPPLEMENTAL MEDWATCH REPORT WILL BE SUBMITTED UPON COMPLETION OF THE INVESTIGATION. (B)(4). LINKED TO MFG. REPORT NUMBERS: 3006697299-2018-00025, 3006697299-2018-00026, AND 2523190-2018-00070. HTTPS://DOI.ORG/10.1016/J.HPB.2017.10.006.

Description of Event or Problem · 1

HPB (2018) PUBLISHED ¿FULLY LAPAROSCOPIC LEFT HEPATECTOMY-A TECHNICAL REFERENCE PROPOSED FOR STANDARD PRACTICE COMPARED TO THE OPEN APPROACH: A RETROSPECTIVE PROPENSITY SCORE MODEL¿ IN WHICH IT DISCUSSED THE SAFETY AND EFFECTIVENESS OF THE LAPAROSCOPIC LEFT HEMIHEPATECTOMY (LLH) TECHNIQUE DEVELOPED AT HENRI MONDOR HOSPITAL SINCE 1996. A SINGLE-SERIES, RETROSPECTIVE PAIR-MATCHED SAFETY/EFFICACY STUDY WAS PERFORMED, COMPARING (LLH) WITH OPEN LEFT HEMIHEPATECTOMY (OLH). THE ANALYSIS COVERED 17 LLH AND 51 OLH PERFORMED FROM 1996 TO 2014. FOR THE LLH, THREE COAGULATION DEVICES WERE UTILIZED: HARMONIC ACE (ULTRACISION, ETHICON ENDO-SURGERY), LIGASURE (COVIDIEN) AND A BIPOLAR FORCEPS (MICROFRANCE) AND ONE ULTRASONIC DISSECTOR (CUSA, INTEGRA). RESULTS: TWO (2) LLH WERE CONVERTED TO OPEN: ONE HAD A TUMOR THROMBUS FOUND INTRAOPERATIVELY IN THE PORTAL VEIN AND AFTER COMPLETION OF SURGERY, THE POSTOPERATIVE COURSE WAS UNEVENTFUL. THE SECOND DEVELOPED HYPOXEMIA DUE TO CO2 EMBOLISM SECONDARY TO LEFT HEPATIC VEIN INJURY AND THE POSTOPERATIVE COURSE WAS UNEVENTFUL. COMPLICATIONS OBSERVED IN FIVE (5) LLH WERE AS FOLLOWS: 1. COMPLICATION: BILIARY LEAK/COLLECTION, CLAVIENDINDO: IIIB, FIBROSIS: 3, STEATOSIS: 5, TREATMENT: LAPAROTOMY, HOSPITAL STAY: 16, DIAGNOSIS: BILIARY CYST 2. COMPLICATION: PNEUMONIA, CLAVIENDINDO: II, FIBROSIS: 1, STEATOSIS: 30, TREATMENT: ANTIBIOTICS, HOSPITAL STAY: 9, DIAGNOSIS: HEPATOCELLULAR CARCINOMA (HCC) 3. COMPLICATION: RESPIRATORY FAILURE, CLAVIENDINDO: II, FIBROSIS: 1, STEATOSIS: 30, TREATMENT: NON-INVASIVE VENTILATION (NIV), HOSPITAL STAY: 7, DIAGNOSIS: HCC 4. COMPLICATION: PNEUMONIA, CLAVIENDINDO: II, FIBROSIS: 4, STEATOSIS: 0, TREATMENT: ANTIBIOTICS, HOSPITAL STAY: 10, DIAGNOSIS: INTRAHEPATIC LITHIASIS 5. COMPLICATION: PULMONARY FAILURE, CLAVIENDINDO: IVA, FIBROSIS: 4, STEATOSIS: 15, TREATMENT: INVASIVE VENTILATION (IV), HOSPITAL STAY: 12, DIAGNOSIS: HCC CONCLUSION: THE TECHNIQUE IS RECOMMENDED AS A POSSIBLE TECHNICAL REFERENCE FOR STANDARD LLH.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
351814 BIPOLAR FORCEPS, UNSPECIFIED BIPOLAR FORCEPS GEI INTEGRA MICROFRANCE S.A.S.

Patients

Seq Age Sex Outcome Treatment
1 Other HARMONIC ACE (ETHICON)| LIGASURE (COVIDIEN)| HARMONIC ACE (ETHICON)| LIGASURE (COVIDIEN)