FDA Adverse Event Death Summary report: N

THERMOCOOL® SMART TOUCH® SF BI-DIRECTIONAL NAVIGATION CATHETER

MDR report key: 7460194 · Received April 25, 2018

Report

Report Number
2029046-2018-01470
Event Type
Death
Date Received
April 25, 2018
Date of Event
February 13, 2018
Report Date
March 27, 2018
Manufacturer
BIOSENSE WEBSTER INC
Product Code
LPB
UDI-DI
10846835010183
PMA / PMN Number
P030031
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
AZ, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

THE PRODUCT WAS DISCARDED, THEREFORE NO PRODUCT FAILURE ANALYSIS CAN BE CONDUCTED AND DEVICE MALFUNCTION CANNOT BE CONFIRMED. DEVICE HISTORY RECORD (DHR) REVIEW CANNOT BE CONDUCTED BECAUSE NO LOT NUMBER WAS PROVIDED BY THE CUSTOMER. BIOSENSE WEBSTER MANUFACTURER'S REFERENCE (B)(4) HAS TWO COMPLAINTS THAT ARE RELATED TO THE SAME INCIDENT. (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED THAT A (B)(6) MALE PATIENT UNDERWENT AN ABLATION PROCEDURE FOR ATRIAL FIBRILLATION WITH A THERMOCOOL® SMART TOUCH® SF BI-DIRECTIONAL NAVIGATION CATHETER AND A SMARTABLATE¿ SYSTEM RF GENERATOR (US) AND SUFFERED AN ESOPHAGEAL FISTULA (REQUIRING UPPER GI IMAGING AND BLOOD PRODUCTS) AND DEATH. APPROXIMATELY 1 MONTH POST-PROCEDURE, AN ATRIOESOPHAGEAL FISTULA WAS CONFIRMED VIA UPPER GI IMAGING. BLOOD PRODUCTS WERE ADMINISTERED. PATIENT REQUIRED EXTENDED HOSPITALIZATION AS A RESULT OF THE ADVERSE EVENT. AT AN UNSPECIFIED POINT, THE PATIENT EXPIRED. PHYSICIAN¿S OPINION REGARDING THE CAUSE OF THE ADVERSE EVENT IS THAT IT WAS PROCEDURE-RELATED. IT WAS NOTED THAT ESOPHAGEAL FISTULA IS A KNOWN COMPLICATION OF THE PROCEDURE. THERE WERE NO ISSUES OR ERRORS REPORTED ON ANY BIOSENSE WEBSTER, INC. PRODUCTS OR EQUIPMENT DURING THE PROCEDURE. GENERATOR WAS SET ON POWER CONTROL MODE AT 30 WATTS AND 37 DEGREES CELSIUS WITH IMPEDANCE OF 95-130 OHMS. THERE IS NO INFORMATION REGARDING OVERALL ABLATION TIME OR LAST ABLATION CYCLE TIME AT THE SITE OF INJURY. ESOPHAGEAL INJURY PREVENTION MODALITIES INCLUDED AN ESOPHAGEAL TEMPERATURE PROBE FOR USE DURING POSTERIOR WALL ABLATION. SHAFT PROXIMITY INTERFERENCE VALUE WAS REPORTED TO BE WITHIN NORMAL LIMITS. THERMOCOOL® SMART TOUCH® SF BI-DIRECTIONAL NAVIGATION CATHETER WAS NOT IN CLOSE PROXIMITY TO ANOTHER CATHETER. THERMOCOOL® SMART TOUCH® SF BI-DIRECTIONAL NAVIGATION CATHETER WAS ZEROED AFTER THE INITIAL WARM-UP PHASE POST CATHETER CONNECTION TO THE CARTO 3 PATIENT INTERFACE UNIT. CARTO 3 SYSTEM DID NOT INDICATE TO RE-ZERO THE CATHETER. THERE WERE NO ISSUES OR ERRORS OBSERVED ON ANY BWI PRODUCTS OR EQUIPMENT DURING THE PROCEDURE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
303407 THERMOCOOL® SMART TOUCH® SF BI-DIRECTIONAL NAVIGATION CATHETER CARDIAC ABLATION PERCUTANEOUS CATHETER LPB BIOSENSE WEBSTER INC UNKNOWN 10846835010183

Patients

Seq Age Sex Outcome Treatment
1 75 YR Death| H| R