FDA Adverse Event Injury Summary report: N

MONOCRYL POLIGLECAPRONE 25 SUTURE UNKNOWN PRODUCT

MDR report key: 7440847 · Received April 18, 2018

Report

Report Number
2210968-2018-72174
Event Type
Injury
Date Received
April 18, 2018
Report Date
March 21, 2018
Manufacturer
ETHICON INC.
Product Code
GAN
PMA / PMN Number
K960653
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NJ, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. CITATION: PLASTIC AND RECONSTRUCTIVE SURGERY. 2010; 125(3). DOI: 10.1097/PRS.0B013E3181CB64F7. (B)(4)

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE: "TITLE: USE OF ABSORBABLE RUNNING BARBED SUTURE AND PROGRESSIVE TENSION TECHNIQUE IN ABDOMINOPLASTY: A NOVEL APPROACH" AUTHORS: ALLEN D. ROSEN, M.D. CITATION: PLASTIC AND RECONSTRUCTIVE SURGERY. 2010; 125(3). DOI: 10.1097/PRS.0B013E3181CB64F7 THE STUDY EVALUATED THE OPERATIVE TIMES, CLOSURE COSTS, AND SAFETY OUTCOMES ASSOCIATED WITH BIDIRECTIONAL BARBED ABSORBABLE SUTURES COMPARED WITH STANDARD SUTURES WHEN USED FOR SOFT-TISSUE APPROXIMATION, INCLUDING FASCIAL REPAIR, IN PATIENTS UNDERGOING COSMETIC ABDOMINOPLASTY. A TOTAL OF 24 PATIENTS UNDERWENT ABDOMINOPLASTY AND WERE INCLUDED IN THE STUDY. OF WHICH, 12 PATIENTS UNDERWENT A STANDARD NON-BARBED SUTURES WITH DRAINS AND ABSORBABLE DEEP DERMAL STAPLES AND 12 PATIENTS UNDERWENT BARBED ABSORBABLE SUTURES WITHOUT DRAINS OR DERMAL STAPLES. IN THE STANDARD NON-BARBED SUTURE GROUP, FASCIAL PLICATION WAS PERFORMED USING SIZE PDS 0 SUTURES, THE PROGRESSIVE TENSION SUTURE USED WAS A PDS 2-0 SUTURE, THEN A SKIN STAPLER WAS USED FOR DEEP DERMAL APPROXIMATION, AND THE SUBCUTICULAR CLOSURE WAS PERFORMED WITH MONOCRYL 4-0 SUTURES. IN THE STANDARD NON-BARBED SUTURE GROUP, REPORTED COMPLICATIONS INCLUDED A SMALL SEROMA IN THE SUBXIPHOID REGION (N-1) WHICH WAS TREATED WITH PUNCTURE ASPIRATION AND FAT NECROSIS IN THE INFRAUMBILICAL REGION (N-1). IT WAS CONCLUDED THAT THE USE OF ABSORBABLE BIDIRECTIONAL BARBED SUTURES FOR REPAIR OF FASCIAL DEFECTS IN ABDOMINOPLASTY, INCLUDING FASCIAL PLICATION, PROGRESSIVE TENSION, AND LAYERED SKIN CLOSURE PROVIDES SATISFACTORY RESULTS; THUS, IT ELIMINATES THE NEED FOR REDUNDANT PERMANENT SUTURE MATERIALS AND KNOTS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
281701 MONOCRYL POLIGLECAPRONE 25 SUTURE UNKNOWN PRODUCT SUTURE, ABSORBABLE, SYNTHETIC GAN ETHICON INC. UNK

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention