HANDPIECE MICS
Report
- Report Number
- 3005985723-2018-00220
- Event Type
- Malfunction
- Date Received
- April 6, 2018
- Date of Event
- March 15, 2018
- Report Date
- May 4, 2018
- Manufacturer
- MAKO SURGICAL CORP.
- Product Code
- OLO
- PMA / PMN Number
- K170581
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- OTHER
Narratives
REPORTED ISSUE: THE HANDPIECE HAD A STUCK TRIGGER. PRODUCT HISTORY REVIEW: DEVICE HISTORY RECORDS INDICATE (B)(4) WERE MANUFACTURED UNDER LOT K06LC AND (B)(4) INCLUDING 4200386 WERE ACCEPTED INTO FINAL STOCK ON 2/2/16. A REVIEW OF (B)(4) REVEALED THAT THE ISSUE IS NOT RELATED TO THE FAILURE ALLEGED IN THIS COMPLIANT. COMPLAINT HISTORY REVIEW: A REVIEW OF COMPLAINTS RELATED TO P/N 209063, S/N (B)(6) IN PRODEX LOT K06LC SHOWS NO ADDITIONAL COMPLAINT(S) RELATED TO THE FAILURE IN THIS INVESTIGATION. VISUAL INSPECTION: VISUAL INSPECTION SHOWS THE TRIGGER IS BINDING AND NOT ALLOWING THE TRIGGER TO FULLY RELEASE TO THE START POSITION. THE TRIGGER IS ABLE TO BE PULLED/FORCED TO THE START (FULLY RELEASED) POSITION. DIMENSIONAL INSPECTION: DIMENSIONAL INSPECTION WAS NOT COMPLETED VISUAL AND FUNCTIONAL INSPECTION CLEARLY SHOWS THE FAILURE OF THE DEVICE. MATERIAL ANALYSIS: MATERIAL ANALYSIS WAS NOT COMPLETED BECAUSE THE FAILURE WAS FUNCTIONAL. FUNCTIONAL INSPECTION: FUNCTIONAL INSPECTION SHOWS THE HANDPIECE DOES NOT OPERATE WHEN THE TRIGGER IS IN THE BINDING STATE, SO THE COMPLAINT IS CONFIRMED. WHEN THE TRIGGER IS PULLED/ FORCED TO THE START (FULLY RELEASED) POSITION THE HANDPIECE STARTS AND ACCELERATES AS THE TRIGGER IS SQUEEZED. AFTER RELEASE OF THE TRIGGER, THE TRIGGER DOES NOT FULLY RELEASE. THE MOTOR CONTINUES TO SLOWLY TURN AS WOULD BE EXPECTED WITH A SLIGHTLY PRESSED TRIGGER. THE MOTOR SHUTS OFF WHEN THE TRIGGER IS PULLED/FORCED TO THE FULLY RELEASED POSITION. CONCLUSION: THE SYSTEM WILL NOT SPIN THE MOTOR IF THE HANDPIECE IS INITIALIZED WITH A PARTIALLY DEPRESSED TRIGGER. A BINDED TRIGGER LOOKS TO THE SYSTEM AS A PARTIALLY DEPRESSED TRIGGER. THE TRIGGER STICKS BECAUSE THE TRIGGER SHAFT IS MADE OF TWO COLLINEAR SHAFTS. THE JUNCTION OF THESE 2 SHAFTS SLIDES THROUGH A BORE. MISALIGNMENT OF THE 2 SHAFTS CAUSES THE TRIGGER TO BIND WHEN THE JUNCTION SLIDES THROUGH THE BORE.
MICS TRIGGER MALFUNCTION. TKA CASE DELAYED 15 MINUTES.
AS PART OF NORMAL COMPLAINT FOLLOW-UP, AN EVALUATION OF THE EVENT HAS BEEN INITIATED BY MAKO SURGICAL. A SUPPLEMENTAL REPORT WILL BE SUBMITTED WHEN ADDITIONAL INFORMATION BECOMES AVAILABLE
MICS TRIGGER MALFUNCTION. TKA CASE DELAYED 15 MINUTES.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 245256 | HANDPIECE MICS | STEREOTAXIC DEVICE, ROBOTICS | OLO | MAKO SURGICAL CORP. | 4200386 / 42020217 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Hospitalization |