HEARTWARE VENTRICULAR ASSIST SYSTEM- PUMP
Report
- Report Number
- 3007042319-2018-01311
- Event Type
- Death
- Date Received
- April 4, 2018
- Date of Event
- March 15, 2018
- Report Date
- May 31, 2018
- Manufacturer
- HEARTWARE, INC.
- Product Code
- DSQ
- PMA / PMN Number
- P100047
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA
- Reporter Occupation
- HEALTH PROFESSIONAL
Narratives
THIS DEVICE IS USED FOR TREATMENT NOT DIAGNOSIS. THE VENTRICULAR ASSIST SYSTEM IS INDICATED FOR USE AS A BRIDGE TO CARDIAC TRANSPLANTATION AND DESTINATION THERAPY IN PATIENTS WHO ARE AT RISK OF DEATH FROM REFRACTORY END-STAGE LEFT VENTRICULAR HEART FAILURE. THE SYSTEM IS DESIGNED FOR IN-HOSPITAL AND OUT-OF-HOSPITAL SETTINGS. WITH A REVIEW OF THE AVAILABLE INFORMATION THERE IS NO EVIDENCE TO INDICATE ANY DEVICE MALFUNCTIONS OR PERFORMANCE ISSUES THAT WOULD IMPACT THE REPORTED EVENTS. POSSIBLE CLINICAL FACTORS THAT MAY HAVE CONTRIBUTED TO THIS EVENT INCLUDE THE PATIENT¿S PRE-EXISTING HISTORY AND RELATED COMORBIDITIES, THE PROGRESSION OF THEIR UNDERLYING DISEASE, ISSUES RELATED TO THE THERAPEUTIC USE OF ANTICOAGULANT AND ANTIPLATELET MEDICATIONS AND THE PATIENT'S COMPLEX POST-OPERATIVE COURSE. THERE ARE POSSIBLE PATIENT, PHARMACOLOGICAL AND PROCEDURAL FACTORS THAT MAY HAVE CONTRIBUTED TO THIS EVENT. THIS INFORMATION IS BASED ENTIRELY ON JOURNAL LITERATURE. ALL INFORMATION PROVIDED IS INCLUDED IN THIS REPORT. PATIENT INFORMATION IS LIMITED DUE TO CONFIDENTIALITY CONCERNS. MULTIPLE PATIENTS WERE NOTED IN THE ARTICLE; HOWEVER, A ONE TO ONE CORRELATION COULD NOT BE MADE WITH UNIQUE DEVICE SERIAL NUMBERS. THE BASELINE GENDER/AGE OF THE PATIENTS REPRESENTED IN THE ARTICLE IS MALE/13 YEARS OLD. THE DATES OF DEATH ARE NOT AVAILABLE AT THE TIME OF THIS REPORT AS THERE IS NO INDICATION OF SPECIFIC SERIAL NUMBER/PATIENT INFORMATION. WITHOUT A LOT NUMBER OR DEVICE SERIAL NUMBER, THE MANUFACTURING DATE CANNOT BE DETERMINED. SINCE NO DEVICE ID WAS PROVIDED, IT IS UNKNOWN IF THIS EVENT HAS BEEN PREVIOUSLY REPORTED. REQUEST FOR ADDITIONAL INFORMATION WILL BE MADE AND UPON RECEIPT A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY. REFERENCED ARTICLE: WORLD-WIDE EXPERIENCE OF A DURABLE CENTRIFUGAL FLOW PUMP IN PEDIATRIC PATIENTS. SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2018 MAR 15. PII: S1043-0679(18)30083-2. DOI: 10.1053/J.SEMTCVS.2018.03.003. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
PRODUCT EVENT SUMMARY: THE PUMPS WITH UNKNOWN SERIAL NUMBERS WERE NOT RETURNED FOR EVALUATION. A REVIEW OF THE MANUFACTURING DOCUMENTATIONS AND STERILIZATION REPORTS COULD NOT BE PERFORMED SINCE THE SERIAL NUMBERS OF THE PUMPS WERE NOT PROVIDED. THE REPORTED EVENT COULD NOT BE CONFIRMED DUE TO INSUFFICIENT INFORMATION. THERE IS NO EVIDENCE TO SUGGEST THAT A DEVICE MALFUNCTION CAUSED OR CONTRIBUTED TO THE REPORTED EVENT. POSSIBLE CLINICAL FACTORS THAT MAY HAVE CONTRIBUTED TO THIS EVENT INCLUDE THE PATIENT¿S PRE-EXISTING HISTORY AND RELATED COMORBIDITIES, THE PROGRESSION OF THEIR UNDERLYING DISEASE, ISSUES RELATED TO THE THERAPEUTIC USE OF ANTICOAGULANT AND ANTIPLATELET MEDICATIONS AND THE PATIENT'S COMPLEX POST-OPERATIVE COURSE. THERE ARE POSSIBLE PATIENT, PHARMACOLOGICAL AND PROCEDURAL FACTORS THAT MAY HAVE CONTRIBUTED TO THIS EVENT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
A JOURNAL ARTICLE WAS REVIEWED WHICH CONTAINED INFORMATION REGARDING VENTRICULAR ASSIST DEVICES (VADS). THE ARTICLE DISCUSSED VADS FOR LEFT VENTRICULAR AND RIGHT VENTRICULAR SUPPORT IN CHILDREN AND ADOLESCENTS. MULTIPLE PATIENTS WERE NOTED IN THE ARTICLE; HOWEVER, A ONE-TO-ONE CORRELATION COULD NOT BE MADE WITH UNIQUE DEVICE SERIAL NUMBERS. THE ARTICLE REPORTED NINETEEN PATIENTS WHO DIED WHILE ON VAD SUPPORT, WITH THE MAJORITY DYING FROM MULTISYSTEM ORGAN FAILURE. PATIENTS ALSO DIED FROM INTRACRANIAL HEMORRHAGE, RIGHT VENTRICULAR FAILURE, INFECTION AND SEPSIS, HEMORRHAGES, NEUROLOGICAL ADVERSE EVENTS, STROKE, HEMORRHAGIC PANCREATITIS AND BOWEL PERFORATION. THE STATUS/LOCATION OF THE VADS IS UNKNOWN.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 239796 | HEARTWARE VENTRICULAR ASSIST SYSTEM- PUMP | VENTRICULAR (ASSISST) BYPASS | DSQ | HEARTWARE, INC. | UNK-PUMP |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 13 YR | Death |