BLAKE DRAIN UNKNOWN PRODUCT
Report
- Report Number
- 2210968-2018-71677
- Event Type
- Injury
- Date Received
- March 27, 2018
- Report Date
- March 2, 2018
- Manufacturer
- ETHICON INC.
- Product Code
- KOG
- PMA / PMN Number
- K953655
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AL, US
- Reporter Occupation
- OTHER
Narratives
(B)(4). IT WAS REPORTED THAT THIS DEVICE IS NOT MALFUNCTION REPORTABLE. THEREFORE, THIS MEDWATCH REPORT IS NOT REPORTABLE.
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. NO SPECIFIC PATIENT INFORMATION REGARDING EVENTS HAS BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. WERE THE CASES DISCUSSED IN THIS ARTICLE PREVIOUSLY REPORTED TO ETHICON? IS THERE AN ALLEGED DEFICIENCY AGAINST THE ETHICON PRODUCTS (PROLENE SUTURE, ETHIBOND SUTURE, BLAKE DRAIN, AND VICRYL SUTURE)? DOES THE PRINCIPAL INVESTIGATOR OPINE THAT THE AES ARE ATTRIBUTED TO THE USE OF ANY OF THE ETHICON PRODUCTS? IF SO, CAN SPECIFIC PATIENT DEMOGRAPHICS BE PROVIDED FOR THE SUBJECTS OF THIS ARTICLE? IF SO, PLEASE INCLUDE: PRE-EXISTING CONDITIONS, EXACT PROCEDURE PERFORMED (IF NOT ALREADY SPECIFIED IN THE LITERATURE), SPECIFIC MEDICAL/ SURGICAL INTERVENTION PER PATIENT. THE PRODUCT CODE AND LOT NUMBER. CITATION: ANN THORAC SURG. 2014; 97: 782 8. DOI: HTTP://DX.DOI.ORG/10.1016/J.ATHORACSUR.2013.09.049.
IT WAS REPORTED VIA JOURNAL ARTICLE: ¿TITLE: CONCOMITANT ROBOTIC MITRAL AND TRICUSPID VALVE REPAIR: TECHNIQUE AND EARLY EXPERIENCE¿ . AUTHORS: CLIFTON T. P. LEWIS, MD., RICHARD L. STEPHENS, PAC, CHARLES M. TYNDAL, CCP, JENNIFER L. CLINE, PHD, ARNP. CITATION: ANN THORAC SURG. 2014; 97: 782 8. DOI: HTTP://DX.DOI.ORG/10.1016/J.ATHORACSUR.2013.09.049. TRICUSPID VALVE REGURGITATION (TR) OFTEN OCCURS SECONDARY TO MITRAL INSUFFICIENCY. IT HAS BEEN CLEARLY ESTABLISHED THAT TRICUSPID VALVE REPAIR (TVP) SHOULD ACCOMPANY MITRAL VALVE REPAIR (MVP) WHEN MODERATE TR OF 2+ OR GREATER IS PRESENT. A TOTAL OF 50 PATIENTS (28 MALE AND 22 FEMALE; AGE RANGE: 64 TO 83 YEARS OLD) WITH ISOLATED MITRAL OR TRICUSPID INSUFFICIENCY WERE CONSIDERED CANDIDATES FOR THE PORT-ACCESS, ROBOTIC COMBINED RMVP RTVP. DURING THE OPERATIVE TECHNIQUE, ALL CANNULAS WERE PLACED IN THE GROIN USING SELDINGER TECHNIQUE UNDER A TRANSESOPHAGEAL ECHOCARDIOGRAPHY (TEE) GUIDANCE, THROUGH PROLENE PURSE STRINGS. DURING RMVP, THE MITRAL RINGS WERE SECURED WITH NITINOL CLIPS, AND LATER ALL ANNULOPLASTY SUTURES WERE TIED EXTRACORPOREALLY WITH ETHIBOND 2-0 SUTURES. DURING RTVP, A FR 28 CHEST TUBE WAS PLACED HIGH IN THE RIGHT PLEURAL SPACE THROUGH THE RIGHT ARM PORT AND A SOFT BLAKE DRAIN WAS PLACED IN THE PERICARDIAL SPACE THROUGH THE THIRD ARM PORT. AFTER HEMOSTASIS, THE OTHER PORTS AND THE GROIN WERE CLOSED WITH VICRYL SUTURE. THE REPORTED COMPLICATIONS INCLUDED HEMOTHORAX (N-6) WHICH REQUIRED RE-OPERATION, ILIAC ARTERY OCCLUSION (N-1) WHICH REQUIRED REVISION SURGERY, MITRAL VALVE REGURGITATION (MR) SECONDARY TO RING DEHISCENCE ASSOCIATED WITH NITINOL CLIP FRACTURE (N-2) WHICH REQUIRED REPEAT REPAIR; 1 PATIENT THROUGH A REDO ROBOTIC APPROACH AND 1 PATIENT THROUGH A STERNOTOMY, AND TR (N-11). IT WAS CONCLUDED THAT COMBINED RMVP-RTVP CAN BE PERFORMED SAFELY AND REPRODUCIBLY WITH ACCEPTABLE EARLY RESULTS. LONG-TERM FOLLOW-UP WILL BE NEEDED TO ESTABLISH THIS AS AN ALTERNATIVE TO TRADITIONAL STERNOTOMY APPROACHES.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 217497 | BLAKE DRAIN UNKNOWN PRODUCT | WOUND DRAINAGE SYSTEM | KOG | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |