FDA Adverse Event Injury Summary report: N

ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN

MDR report key: 7370545 · Received March 26, 2018

Report

Report Number
2210968-2018-71649
Event Type
Injury
Date Received
March 26, 2018
Report Date
March 2, 2018
Manufacturer
ETHICON INC.
Product Code
GAT
PMA / PMN Number
K946173
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
AL, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. NO SPECIFIC PATIENT INFORMATION REGARDING EVENTS HAS BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. CITATION: ANN THORAC SURG. 2014; 97: 782 8. DOI: HTTP://DX.DOI.ORG/10.1016/J.ATHORACSUR.2013.09.049.

Additional Manufacturer Narrative · 1

PC-000139736 CORRECTED INFORMATION. IT WAS REPORTED THAT THIS DEVICE IS NOT MALFUNCTION REPORTABLE. THEREFORE, THIS MEDWATCH REPORT IS NOT REPORTABLE.

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE: ¿TITLE: CONCOMITANT ROBOTIC MITRAL AND TRICUSPID VALVE REPAIR: TECHNIQUE AND EARLY EXPERIENCE¿ AUTHORS: CLIFTON T. P. LEWIS, MD., RICHARD L. STEPHENS, PAC, CHARLES M. TYNDAL, CCP, JENNIFER L. CLINE, PHD, ARNP CITATION: ANN THORAC SURG. 2014; 97: 782 8. DOI: HTTP://DX.DOI.ORG/10.1016/J.ATHORACSUR.2013.09.049. TRICUSPID VALVE REGURGITATION (TR) OFTEN OCCURS SECONDARY TO MITRAL INSUFFICIENCY. IT HAS BEEN CLEARLY ESTABLISHED THAT TRICUSPID VALVE REPAIR (TVP) SHOULD ACCOMPANY MITRAL VALVE REPAIR (MVP) WHEN MODERATE TR OF 2+ OR GREATER IS PRESENT. A TOTAL OF 50 PATIENTS (28 MALE AND 22 FEMALE; AGE RANGE: 64 TO 83 YEARS OLD) WITH ISOLATED MITRAL OR TRICUSPID INSUFFICIENCY WERE CONSIDERED CANDIDATES FOR THE PORT-ACCESS, ROBOTIC COMBINED RMVP RTVP. DURING THE OPERATIVE TECHNIQUE, ALL CANNULAS WERE PLACED IN THE GROIN USING SELDINGER TECHNIQUE UNDER A TRANSESOPHAGEAL ECHOCARDIOGRAPHY (TEE) GUIDANCE, THROUGH PROLENE PURSE STRINGS. DURING RMVP, THE MITRAL RINGS WERE SECURED WITH NITINOL CLIPS, AND LATER ALL ANNULOPLASTY SUTURES WERE TIED EXTRACORPOREALLY WITH ETHIBOND 2-0 SUTURES. DURING RTVP, A FR 28 CHEST TUBE WAS PLACED HIGH IN THE RIGHT PLEURAL SPACE THROUGH THE RIGHT ARM PORT AND A SOFT BLAKE DRAIN WAS PLACED IN THE PERICARDIAL SPACE THROUGH THE THIRD ARM PORT. AFTER HEMOSTASIS, THE OTHER PORTS AND THE GROIN WERE CLOSED WITH VICRYL SUTURE. THE REPORTED COMPLICATIONS INCLUDED HEMOTHORAX (N-6) WHICH REQUIRED RE-OPERATION, ILIAC ARTERY OCCLUSION (N-1) WHICH REQUIRED REVISION SURGERY, MITRAL VALVE REGURGITATION (MR) SECONDARY TO RING DEHISCENCE ASSOCIATED WITH NITINOL CLIP FRACTURE (N-2) WHICH REQUIRED REPEAT REPAIR; 1 PATIENT THROUGH A REDO ROBOTIC APPROACH AND 1 PATIENT THROUGH A STERNOTOMY, AND TR (N-11). IT WAS CONCLUDED THAT COMBINED RMVP-RTVP CAN BE PERFORMED SAFELY AND REPRODUCIBLY WITH ACCEPTABLE EARLY RESULTS. LONG-TERM FOLLOW-UP WILL BE NEEDED TO ESTABLISH THIS AS AN ALTERNATIVE TO TRADITIONAL STERNOTOMY APPROACHES.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
213184 ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN SUTURE, NONABSORBABLE, SYNTHETIC GAT ETHICON INC. UNK

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention