FDA Adverse Event Other Summary report: N

MW5076102

MDR report key: 7369578 · Received March 26, 2018

Report

Report Number
MW5076102
Event Type
Other
Date Received
March 26, 2018
Date of Event
April 29, 2017
Report Date
March 22, 2018
Report Source
Voluntary report
Reporter Location
MD, US
Reporter Occupation
NURSE

Narratives

Description of Event or Problem · 1

PATIENT PRESENTED WITH RIGHT FINGER SWELLING FROM JAMMING FINGER. SUBUNGUAL HEMATOMA, PROVIDER USED ETHYL CHLORIDE, OR "FREEZY SPRAY" BEFORE THE PROCEDURE. THE SPRAY WAS FLAMMABLE, AND THE CAUTERY IGNITED THE CHUX UNDERNEATH. PROVIDER EXTINGUISHED THE FLAMES, NO HARM TO PATIENT. THE PRODUCT IS NOT CLEARLY LABELED AND IDENTIFIABLE FOR RISK OF FLAMMABILITY. THE PRODUCT IS GEBAUER'S ETHYL CHLORIDE, BY THE GEBAUER COMPANY. DOSE OR AMOUNT: 103.5 ML. FREQUENCY: PRN. ROUTE: TOPICAL. DATES OF USE: (B)(6) 2017. DIAGNOSIS OR REASON FOR USE: SUBUNGUAL HEMATOMA OF NAILBED. IS THE PRODUCT COMPOUNDED: NO. IS THE PRODUCT OVER-THE-COUNTER: NO. EVENT ABATED AFTER USE STOPPED OR DOSE REDUCED: YES.

Patients

Seq Age Sex Outcome Treatment
1 10 YR