PROXIMATE*SKIN STPLR (EXACT CODE UNKNOWN)
Report
- Report Number
- 3005075853-2018-08622
- Event Type
- Injury
- Date Received
- March 20, 2018
- Report Date
- February 27, 2018
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- GDT
- PMA / PMN Number
- K833357
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- OTHER
Narratives
(B)(4). DATE SENT: 3/28/2018. CORRECTED DATA: MDR DECISION: NOT REPORTABLE. UPON REVIEW OF THE INFORMATION PROVIDED, IT WAS CONCLUDED THAT THIS EVENT DOES NOT MEET THE FDA DEFINED CRITERIA FOR A REPORTABLE EVENT AND IS BEING CONSIDERED NOT REPORTABLE. ADDITIONAL INFORMATION OBTAINED: PER THE AUTHOR, THE COMPLICATIONS MENTIONED IN THE ARTICLE WERE NOT RELATED TO ETHICON DEVICES.
(B)(4) BATCH # UNK THE LOT/BATCH WAS NOT PROVIDED; THEREFORE, THE MANUFACTURING RECORDS COULD NOT BE REVIEWED. ATTEMPTS WERE MADE TO OBTAIN THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT.
IT WAS REPORTED VIA JOURNAL ARTICLE: TITLE: A PROSPECTIVE RANDOMISED COMPARISON OF 2 SKIN CLOSURE TECHNIQUES IN PRIMARY TOTAL HIP ARTHROPLASTY SURGERY. AUTHOR(S): RUI M, ZHENG X, SUN SS, LI CY, ZHANG XC, GUO KJ, ZHAO FC, PANG Y CITATION: HIP INT. 2017 NOV 13:0. DOI: 10.5301/HIPINT.5000534. THE PURPOSE OF THIS PROSPECTIVE RANDOMISED CLINICAL STUDY WAS TO COMPARE THE CLINICAL OUTCOMES AND COSTS BETWEEN STAPLES AND SUBCUTICULAR SUTURE TECHNIQUES. FROM MAR2014 TO JUN2014, 165 PATIENTS WHO UNDERWENT PRIMARY UNILATERAL THA THROUGH A POSTEROLATERAL APPROACH WERE RANDOMIZED INTO TWO SKIN CLOSURE TECHNIQUES: STAPLER GROUP (N=83; N=36 MALE, N=47 FEMALE; MEAN AGE 55.7 YEARS) AND SUTURE GROUP (N=82; N=39 MALE, N=43 FEMALE; MEAN AGE 57.8 YEARS). IN SUTURE GROUP, SUPERFICIAL SKIN CLOSURE WERE CLOSED WITH A RUNNING SUBTICULAR 4-0 VICRYL SUTURES. IN STAPLER GROUP, WOUNDS WERE CLOSED WITH METALLIC SKIN STAPLES (JOHNSON AND JOHNSON INC.). IN STAPLER GROUP, 2 PATIENTS ((B)(6) FEMALE AND (B)(6) MALE) EXPERIENCED SUPERFICIAL SURGICAL SITE INFECTIONS. THE PATIENT WERE TREATED WITH INTRAVENOUS CEFUROXIME (1.5 G/DAY) AND A 75% ALCOHOL SOAKED DRESSING WAS UTILIZED AND CHANGED PER DAY. CLOSURE WITH RUNNING SUBCUTICULAR SUTURE IS CHEAPER AND APPEARS TO HAVE A CLINICAL ADVANTAGE WHEN COMPARED WITH METALLIC STAPLES SKIN CLOSURE IN PRIMARY THA SURGERY.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 198934 | PROXIMATE*SKIN STPLR (EXACT CODE UNKNOWN) | REMOVABLE (SKIN) | GDT | ETHICON ENDO-SURGERY, LLC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |