FDA Adverse Event Injury Summary report: N

UNKNOWN IMPLANTABLE NEUROSTIMULATOR

MDR report key: 7318493 · Received March 6, 2018

Report

Report Number
3007566237-2018-00665
Event Type
Injury
Date Received
March 6, 2018
Date of Event
July 14, 2017
Report Date
March 6, 2018
Manufacturer
MEDTRONIC NEUROMODULATION
Product Code
MHY
PMA / PMN Number
P960009
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
LO
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

IT WAS NOT POSSIBLE TO ASCERTAIN SPECIFIC DEVICE INFORMATION FROM THE ARTICLE OR TO MATCH THE EVENTS REPORTED WITH PREVIOUSLY REPORTED EVENTS. THE MAIN COMPONENT OF ONE OF THE SYSTEMS INVOLVED IN THE REPORTED EVENTS; OTHER APPLICABLE COMPONENTS ARE: PRODUCT ID: NEU_UNKNOWN_LEAD, LOT# UNKNOWN, PRODUCT TYPE: LEAD. PRODUCT ID: NEU_STIMLOC_ACC, LOT# UNKNOWN, PRODUCT TYPE: ACCESSORY. KLOC, M., KOSUTZKA, Z., STENO, J., VALKOVIC, P. PREVALENT PLACEMENT ERROR OF DEEP BRAIN STIMULATION ELECTRODE IN MOVEMENT DISORDERS (TECHNICAL CONSIDERATIONS). BRATISL LEK LISTY. 2017;118(11):647-653. DOI: 10.4149/BLL_2017_123 " IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 1

SUMMARY: BACKGROUND: DEEP BRAIN STIMULATION IS AN EFFECTIVE AND SAFE TECHNIQUE. DISPLACEMENT OF THE ELECTRODE RELATIVE TO THE OPTIMAL STIMULATION SITE CAN LEAD TO INSUFFICIENT EFFECT AND SOMETIMES TO THE NEED OF OPERATIVE ELECTRODE RE-POSITION. OBJECTIVE: THIS STUDY WAS AIMED TO ANALYSE TARGETING ACCURACY OF DEEP BRAIN STIMULATION ELECTRODE IMPLANTATION TO SUBTHALAMIC NUCLEUS (STN) AND GLOBUS PALLIDUS INTERNUS (GPI). IT DETECTED POSSIBLE CAUSES OF INACCURACY AND PREVALENT SHIFT TO CERTAIN DIRECTION. METHODS: TARGETING ACCURACY WAS ANALYSED IN 47 PATIENTS WITH PARKINSON´S DISEASE (PD) AND 11 PATIENTS WITH DYSTONIA WITH BILATERAL IMPLANTATION OF DEEP BRAIN STIMULATION ELECTRODES BETWEEN YEARS 2009 AND 2016. RESULTS: A SHIFT OF ELECTRODE TO PREVALENT DIRECTION WAS OBSERVED ON THE LEFT SIDE TO MEDIAL AND POSTERIOR AND ON THE RIGHT SIDE TO LATERAL DIRECTION. GREATER SHIFT WAS OBSERVED ON THE LEFT SIDE AND IN A HIGHER ANGULATION OF TRAJECTORY LATERALLY. MOVEMENT OF THE ELECTRODE, BECAUSE OF ITS TRACTION IN ANCHORING DEVICE, WAS IDENTIFIED AS A POSSIBLE FACTOR FOR PREVALENT ELECTRODE SHIFT. CALIBRATION OF STEREOTACTIC COORDINATES TO CORRECT PREVALENT SHIFT WAS USED. CONCLUSION: TARGETING INACCURACY IS THE RESULT OF ACCUMULATION OF ERRORS IN INDIVIDUAL STEPS OF ELECTRODE IMPLANTATION. DIRECTION OF THE SHIFT CAN BE RANDOM OR IT CAN BE TOWARD A PREVALENT DIRECTION. A CORRECTION OF PREVALENT ERROR CAN PREVENT A SUBOPTIMAL ELECTRODE PLACEMENT. REPORTED EVENTS: A PATIENT WITH SUBTHALAMIC NUCLEUS (STN) DEEP BRAIN STIMULATION (DBS) FOR PARKINSON'S DISEASE (PD) HAD A 3.6 MM SHIFT OF THE LEFT ELECTRODE, IN THE PLANE OF THE STIMLOC IN A MEDIAL DIRECTION TOWARDS THE CENTER OF THE BURR HOLE. THIS ERROR REPORTEDLY REQUIRED AN OPERATIVE REPOSITIONING OF THE ELECTRODE BECAUSE OF INSUFFICIENT STIMULATION EFFECT. ANGULATION AND BENDING OF THE ELECTRODE WAS NOTICED INTRACRANIALLY. SPECIFICALLY, THEY HAD 3 MM OF ELECTRODE BENDING AND A SHIFT OF THE LEAD IN THE STIMLOC DEVICE. THE AUTHORS ADDED THAT THERE WERE SEVERAL PATIENTS WITH ERRORS CLOSE 2 MM WITH PNEUMOCEPHALUS ON POSTOPERATIVE CT. IT WAS NOT POSSIBLE TO ASCERTAIN SPECIFIC DEVICE INFORMATION FROM THE ARTICLE OR TO MATCH THE REPORTED EVENT WITH ANY PREVIOUSLY REPORTED EVENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
160934 UNKNOWN IMPLANTABLE NEUROSTIMULATOR STIMULATOR, ELECTRICAL, IMPLANTED, FOR PARKINSONIAN TREMOR MHY MEDTRONIC NEUROMODULATION NEU_INS_STIMULATOR UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention