FDA Adverse Event Malfunction Summary report: N

DEVILBISS

MDR report key: 7310969 · Received March 2, 2018

Report

Report Number
2515872-2018-00004
Event Type
Malfunction
Date Received
March 2, 2018
Date of Event
January 1, 2018
Report Date
February 2, 2018
Manufacturer
DEVILBISS HEALTHCARE LLC
Product Code
LEL
PMA / PMN Number
K112220
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
GM
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

THE DEVILBISS INTELLIPAP MODEL DV53 SERIES STANDARD PLUS CPAP INTENDED USE IS IN THE TREATMENT OF OBSTRUCTIVE SLEEP APNEA SYNDROME (OSA) IN SPONTANEOUSLY BREATHING PATIENTS (B)(6) AND ABOVE BY MEANS OF APPLICATION OF POSITIVE AIR PRESSURE. THE DEVICE IS INTENDED TO BE USED IN HOME AND CLINICAL ENVIRONMENTS. THE CPAP MODEL DV54NE-P WAS EVALUATED BY OUR ENGINEERING DEPARTMENT. THE INVESTIGATION REVEALS EVIDENCE OF A THERMAL EVENT THAT WAS TRACED TO THE OXYGEN INLET PORT ADAPTER, WHICH WAS LOCATED AT THE HUMIDIFIER FLOW OUTLET BETWEEN THE OUTLET AND THE CPAP SUPPLY TUBING. THE THERMAL DAMAGE PATTERNS INDICATE THE OXYGEN WAS FLOWING INTO THE CPAP WHILE THE CPAP BLOWER WAS NOT OPERATING (OXYGEN FLOWING INTO THE UNIT FROM THE GAS SOURCE BUT THE CPAP DEVICE WAS NOT TURNED ON). ALLOWING OXYGEN TO FLOW INTO THE CPAP UNIT THAT IS NOT OPERATING IS CONTRAINDICATED, AS NOTED IN THE DV54NE-P USER MANUAL SE-DV53-2 REV A IN THE SECTION "WARNING- OXYGEN USE", WHICH PROVIDES CLEAR WARNING OF THE DANGER AND RISK OF FIRE ASSOCIATED WITH OXYGEN FLOWING INTO THE CPAP WITHOUT THE BLOWER OPERATING. THE INVESTIGATION AND FINDINGS INDICATE THAT USER DID NOT FOLLOW THE INSTRUCTIONS IN THE PRODUCT'S USER MANUAL.

Description of Event or Problem · 1

AS COMMUNICATED IN AN EMAIL TO DEVILBISS FROM OUR EC REPRESENTATIVE, THE DISTRIBUTOR BASED IN (B)(6) ((B)(4)) ADVISED ABOUT AN EVENT ASSOCIATED WITH A CPAP SLEEPCUBE, MODEL DV54NE-P. THE DISTRIBUTOR COMMUNICATED THE FOLLOWING INFORMATION: "EVENT LOCATION: LIVING ROOM THE PATIENT IN (B)(6). EVENT DESCRIPTION: THE DEVICE WAS CONNECTED TO THE POWER LINE AND THE CUSTOMER LEFT THE ROOM IN WHICH THE DEVICE WAS LOCATED. SHORTLY THEREAFTER, THE SMOKE ALARM SOUNDED AND THE APPLIANCE BURNED ACCORDING TO THE MESSAGE ON (OR NEAR) THE AIR OUTLET OF THE HUMIDIFIER." IN A SUBSEQUENT COMMUNICATION WITH THE DISTRIBUTOR, IT WAS CONFIRMED THAT THE CPAP UNIT WAS CONNECTED TO AN OXYGEN SOURCE; AND "THERE WAS NO INJURY ON THE PATIENT AND MAY HAVE BEEN A WRONG INTEND OF USAGE." IT WAS ALSO CONFIRMED THE DEVICE WAS NOT BEING USED FOR TREATMENT AND/OR FOR DIAGNOSIS WHEN THE INCIDENT HAPPENED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
152502 DEVILBISS INTELLIPAP LEL DEVILBISS HEALTHCARE LLC DV5

Patients

Seq Age Sex Outcome Treatment
1 84 YR