FDA Adverse Event Injury Summary report: N

METASUL LDH, HEAD, 44, CODE J, TAPER 18/20

MDR report key: 7288158 · Received February 22, 2018

Report

Report Number
0009613350-2018-00281
Event Type
Injury
Date Received
February 22, 2018
Date of Event
February 3, 2008
Report Date
February 22, 2018
Manufacturer
ZIMMER GMBH
Product Code
KWA
PMA / PMN Number
PSEE H10
Removal / Correction Number
N/A
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
ATTORNEY

Narratives

Additional Manufacturer Narrative · 1

THIS PRODUCT IS MANUFACTURED BY ZIMMER BIOMET (B)(4) AND IS NOT CLEARED OR DISTRIBUTED IN THE U.S. HOWEVER, THIS REPORT IS BEING SUBMITTED AS ZIMMER BIOMET (B)(4) MANUFACTURES A SIMILAR DEVICE THAT IS CLEARED OR DISTRIBUTED IN THE UNITED STATES UNDER 510(K) NUMBER K091973. DUE TO FACT THAT THIS IS A LEGAL CLAIM, OUR LEGAL DEPARTMENT HAS BEEN PROVIDED WITH THE AVAILABLE FACTS FROM THE CUSTOMER. ZIMMER (B)(4) LEGAL DEPARTMENT IS WELL TRAINED AND PASSES ALL INFORMATION CONCERNING THE CASE TO OUR COMPLAINT HANDLING DEPARTMENT. THE MANUFACTURER DID NOT RECEIVE DEVICES OR X-RAYS FOR REVIEW. WHERE LOT NUMBERS WERE RECEIVED FOR THE DEVICES, THE DEVICE HISTORY RECORDS WERE REVIEWED AND FOUND TO BE CONFORMING. BASED ON AN EXTENSIVE INVESTIGATION OF EVENTS REPORTED FROM SEVERAL USER FACILITIES OUTSIDE THE USA, ZIMMER IDENTIFIED THAT THE MOST PROBABLE CAUSE FOR THE OUTCOME OBSERVED WAS A LOOSE OR UNSTABLE CUP THAT RESULTED FROM USE OF SURGICAL TECHNIQUES NOT CONSISTENT WITH THE MANUFACTURER'S RECOMMENDATIONS. AS A CORRECTIVE ACTION, A RETRAINING PROGRAM FOR USERS OUTSIDE THE USA WAS INITIATED IN NOVEMBER 2009 AND REPORTED TO THE NATIONAL COMPETENT AUTHORITIES AS REQUIRED. THE DUROM CUP REPORTED IN THIS CASE IS NOT MARKETED IN THE USA. A SIMILAR CUP, COMPATIBLE WITH THE METASUL LDH FEMORAL HEAD, IS CLEARED IN THE USA AND A CORRECTIVE ACTION FOR THIS PRODUCT WAS REPORTED TO THE FDA IN JULY 2008 AS NOTIFICATION Z-2415/2426-2008. SINCE THIS CASE IS RELATED TO THE ISSUES FOR WHICH ZIMMER IMPLEMENTED A CORRECTIVE ACTION THERE WILL BE NO FURTHER INVESTIGATION. THEREFORE, ZIMMER (B)(4) CONSIDERS THIS CASE AS CLOSED. ZIMMER¿S REFERENCE NUMBER OF THIS FILE IS (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION SURGERY APPROXIMATELY NINE MONTHS POST IMPLANTATION DUE TO RECURRENT INFECTION, PAIN, CYST, FLUID COLLECTION AND SWELLING. ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION HAVE BEEN MADE; HOWEVER, NO MORE IS AVAILABLE

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
133862 METASUL LDH, HEAD, 44, CODE J, TAPER 18/20 KWA ZIMMER GMBH N/A 2353685

Patients

Seq Age Sex Outcome Treatment
1 44 YR Hospitalization| R ACETABULUM, ITEM# 0100214050, LOT# 2331227| HEAD ADAPTER, ITEM# 0100185146, LOT# 2341071| TAPER STEM, ITEM# 00992201713, LOT# 60077818| TAPER, ITEM# 00992308345, LOT# 60077186