FDA Adverse Event Injury Summary report: N

METASUL DUROM, COMPONENT FOR ACETABULUM, UNCEMENTED, 50, 44, CODE J

MDR report key: 7281659 · Received February 20, 2018

Report

Report Number
0009613350-2018-00253
Event Type
Injury
Date Received
February 20, 2018
Report Date
February 20, 2018
Manufacturer
ZIMMER GMBH
Product Code
KWA
PMA / PMN Number
PSEE H10
Removal / Correction Number
N/A
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NL
Reporter Occupation
ATTORNEY

Narratives

Additional Manufacturer Narrative · 1

DUE TO FACT THAT THIS IS A LEGAL CLAIM, OUR LEGAL DEPARTMENT HAS BEEN PROVIDED WITH THE AVAILABLE FACTS FROM THE CUSTOMER. ZIMMER (B)(4) LEGAL DEPARTMENT IS WELL TRAINED AND PASSES ALL INFORMATION CONCERNING THE CASE TO OUR COMPLAINT HANDLING DEPARTMENT. THIS PRODUCT IS MANUFACTURED BY ZIMMER BIOMET (B)(4) AND IS NOT CLEARED OR DISTRIBUTED IN THE U.S. HOWEVER, THIS REPORT IS BEING SUBMITTED AS ZIMMER BIOMET (B)(4) MANUFACTURES A SIMILAR DEVICE THAT IS CLEARED OR DISTRIBUTED IN THE UNITED STATES UNDER 510(K) NUMBER K053536. THE DEVICE WILL NOT BE RETURNED FOR ANALYSIS; HOWEVER, AN INVESTIGATION OF THE REPORTED EVENT WAS MADE. BASED ON AN EXTENSIVE INVESTIGATION OF EVENTS REPORTED FROM SEVERAL USER FACILITIES OUTSIDE THE USA, ZIMMER IDENTIFIED THAT THE MOST PROBABLE CAUSE FOR THE OUTCOME OBSERVED WAS A LOOSE OR UNSTABLE CUP THAT RESULTED FROM USE OF SURGICAL TECHNIQUES NOT CONSISTENT WITH THE MANUFACTURER'S RECOMMENDATIONS. AS A CORRECTIVE ACTION, A RETRAINING PROGRAM FOR USERS OUTSIDE THE USA WAS INITIATED IN NOVEMBER 2009 AND REPORTED TO THE NATIONAL COMPETENT AUTHORITIES AS REQUIRED. THE DUROM CUP REPORTED IN THIS CASE IS NOT MARKETED IN THE USA. A SIMILAR CUP, COMPATIBLE WITH THE METASUL LDH FEMORAL HEAD, IS CLEARED IN THE USA AND A CORRECTIVE ACTION FOR THIS PRODUCT WAS REPORTED TO THE FDA IN JULY 2008 AS NOTIFICATION Z-2415/2426-2008. SINCE THIS CASE IS RELATED TO THE ISSUES FOR WHICH ZIMMER IMPLEMENTED A CORRECTIVE ACTION THERE WILL BE NO FURTHER INVESTIGATION. THEREFORE, ZIMMER (B)(4) CONSIDERS THIS CASE AS CLOSED. ZIMMER BIOMET¿S REFERENCE NUMBER OF THIS FILE IS (B)(4).

Description of Event or Problem · 1

A PATIENT IS PURSUING A PRODUCT LIABILITY CLAIM. IT WAS REPORTED THAT THE PATIENT IS BEING MONITORED APPROXIMATELY SEVEN YEARS POST IMPLANTATION DUE TO ELEVATED METAL IONS IN THE BLOOD. ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION HAVE BEEN MADE; HOWEVER, NO MORE IS AVAILABLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
125493 METASUL DUROM, COMPONENT FOR ACETABULUM, UNCEMENTED, 50, 44, CODE J KWA ZIMMER GMBH N/A 2479184

Patients

Seq Age Sex Outcome Treatment
1 Other HEAD ADAPTER, ITEM# 0100185145, LOT# 2462043| HEAD, ITEM# 0100181440, LOT# 2480992| STEM, ITEM# 290039100, LOT# UNKNOWN