METASUL DUROM, COMPONENT FOR ACETABULUM, UNCEMENTED, 50, 44, CODE J
Report
- Report Number
- 0009613350-2018-00253
- Event Type
- Injury
- Date Received
- February 20, 2018
- Report Date
- February 20, 2018
- Manufacturer
- ZIMMER GMBH
- Product Code
- KWA
- PMA / PMN Number
- PSEE H10
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NL
- Reporter Occupation
- ATTORNEY
Narratives
DUE TO FACT THAT THIS IS A LEGAL CLAIM, OUR LEGAL DEPARTMENT HAS BEEN PROVIDED WITH THE AVAILABLE FACTS FROM THE CUSTOMER. ZIMMER (B)(4) LEGAL DEPARTMENT IS WELL TRAINED AND PASSES ALL INFORMATION CONCERNING THE CASE TO OUR COMPLAINT HANDLING DEPARTMENT. THIS PRODUCT IS MANUFACTURED BY ZIMMER BIOMET (B)(4) AND IS NOT CLEARED OR DISTRIBUTED IN THE U.S. HOWEVER, THIS REPORT IS BEING SUBMITTED AS ZIMMER BIOMET (B)(4) MANUFACTURES A SIMILAR DEVICE THAT IS CLEARED OR DISTRIBUTED IN THE UNITED STATES UNDER 510(K) NUMBER K053536. THE DEVICE WILL NOT BE RETURNED FOR ANALYSIS; HOWEVER, AN INVESTIGATION OF THE REPORTED EVENT WAS MADE. BASED ON AN EXTENSIVE INVESTIGATION OF EVENTS REPORTED FROM SEVERAL USER FACILITIES OUTSIDE THE USA, ZIMMER IDENTIFIED THAT THE MOST PROBABLE CAUSE FOR THE OUTCOME OBSERVED WAS A LOOSE OR UNSTABLE CUP THAT RESULTED FROM USE OF SURGICAL TECHNIQUES NOT CONSISTENT WITH THE MANUFACTURER'S RECOMMENDATIONS. AS A CORRECTIVE ACTION, A RETRAINING PROGRAM FOR USERS OUTSIDE THE USA WAS INITIATED IN NOVEMBER 2009 AND REPORTED TO THE NATIONAL COMPETENT AUTHORITIES AS REQUIRED. THE DUROM CUP REPORTED IN THIS CASE IS NOT MARKETED IN THE USA. A SIMILAR CUP, COMPATIBLE WITH THE METASUL LDH FEMORAL HEAD, IS CLEARED IN THE USA AND A CORRECTIVE ACTION FOR THIS PRODUCT WAS REPORTED TO THE FDA IN JULY 2008 AS NOTIFICATION Z-2415/2426-2008. SINCE THIS CASE IS RELATED TO THE ISSUES FOR WHICH ZIMMER IMPLEMENTED A CORRECTIVE ACTION THERE WILL BE NO FURTHER INVESTIGATION. THEREFORE, ZIMMER (B)(4) CONSIDERS THIS CASE AS CLOSED. ZIMMER BIOMET¿S REFERENCE NUMBER OF THIS FILE IS (B)(4).
A PATIENT IS PURSUING A PRODUCT LIABILITY CLAIM. IT WAS REPORTED THAT THE PATIENT IS BEING MONITORED APPROXIMATELY SEVEN YEARS POST IMPLANTATION DUE TO ELEVATED METAL IONS IN THE BLOOD. ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION HAVE BEEN MADE; HOWEVER, NO MORE IS AVAILABLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 125493 | METASUL DUROM, COMPONENT FOR ACETABULUM, UNCEMENTED, 50, 44, CODE J | KWA | ZIMMER GMBH | N/A | 2479184 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other | HEAD ADAPTER, ITEM# 0100185145, LOT# 2462043| HEAD, ITEM# 0100181440, LOT# 2480992| STEM, ITEM# 290039100, LOT# UNKNOWN |