FDA Adverse Event Malfunction Summary report: N

PULLING DEVICE Ø4 L240 F/LISS

MDR report key: 7277867 · Received February 16, 2018

Report

Report Number
8030965-2018-51194
Event Type
Malfunction
Date Received
February 16, 2018
Date of Event
January 24, 2018
Report Date
January 24, 2018
Manufacturer
OBERDORF SYNTHES PRODUKTIONS GMBH
Product Code
FZX
UDI-DI
07611819221345
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
HU
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

DEPUY SYNTHES IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHES OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. H10 ADDITIONAL NARRATIVE: H3, H4, H6: A DEVICE HISTORY RECORD (DHR) REVIEW WAS PERFORMED FOR PART NUMBER: 324.033, SYNTHES LOT NUMBER: L102361: RELEASE TO WAREHOUSE DATE: 23.AUGUST 2016, MANUFACTURING SITE: BETTLACH: NO NON-CONFORMANCE REPORTS (NCRS) WERE GENERATED DURING PRODUCTION. REVIEW OF THE DEVICE HISTORY RECORD(S) SHOWED THAT THERE WERE NO ISSUES DURING THE MANUFACTURE OF THE PRODUCT THAT WOULD CONTRIBUTE TO THIS COMPLAINT CONDITION. H3, H6: A PRODUCT INVESTIGATION WAS PERFORMED. THE INVESTIGATION OF THE COMPLAINED PULLING DEVICE HAS SHOWN THAT APPROXIMATELY 30MM FROM THE TIP SECTION BROKE OFF. FURTHER INVESTIGATION HAS SHOWN THAT THE CUTTING EDGES OF THE DRILL ARE WORN OUT. BECAUSE OF THE DAMAGE THE COMPLAINT RELEVANT DIMENSIONS CANNOT BE CHECKED TO PRINT SPECIFICATIONS ANYMORE. THE MANUFACTURING DOCUMENT SHOWS THAT THE PRODUCTION PROCEDURE WAS ACCORDING TO THE SPECIFICATIONS AND THERE WERE NO ISSUES THAT WOULD CONTRIBUTE TO THIS COMPLAINT CONDITION. THE HARDNESS OF MATERIAL WAS WITHIN THE SPECIFICATION. THE BROKEN SURFACE IS HOMOGENOUS WHAT INDICATES MATERIAL CONFORMITY AS WELL. UNFORTUNATELY, WE ARE NOT ABLE TO DETERMINE THE EXACT CAUSE OF THE BREAKAGE. WE CAN ONLY ASSUME THAT A MECHANICAL OVERLOAD BY APPLYING TO MUCH FORCE DURING A PULLING MANEUVER DID LEAD TO THIS BREAKAGE, THIS WOULD ALSO EXPLAIN THE CLEARLY VISIBLE HEAVY STRESS MARKS AT THE BOTTOM OF THE NUT. BASED ON THESE FINDINGS WE CONCLUDE THAT THE CAUSE OF FAILURE IS NOT DUE TO ANY MANUFACTURING NON-CONFORMANCES. IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED. H10 CORRECTED DATA: DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 1

REPORTEDLY THERE WAS NO PATIENT INVOLVEMENT. DEVICE IS AN INSTRUMENT AND IS NOT IMPLANTED/EXPLANTED. A DEVICE HISTORY RECORD REVIEW WAS REQUESTED. THE DEVICE WAS RECEIVED, THE INVESTIGATION COULD NOT BE COMPLETED, AND NO CONCLUSION COULD BE DRAWN, AS PRODUCT IS ENTERING THE COMPLAINT SYSTEM. (B)(4). DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

DEVICE REPORT FROM SYNTHES EUROPE REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT DURING CLEANING AND DECONTAMINATION THE DEVICE WAS FOUND BROKEN. NO PATIENT INVOLVEMENT. (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
121624 PULLING DEVICE Ø4 L240 F/LISS GUIDE FZX OBERDORF SYNTHES PRODUKTIONS GMBH L102361 07611819221345

Patients

Seq Age Sex Outcome Treatment
1