DISTAFLO BYPASS GRAFT
Report
- Report Number
- 2020394-2017-01864
- Event Type
- Injury
- Date Received
- January 3, 2018
- Date of Event
- November 8, 2016
- Report Date
- March 2, 2018
- Manufacturer
- BARD PERIPHERAL VASCULAR, INC.
- Product Code
- DSY
- PMA / PMN Number
- K983861
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- UK
- Reporter Occupation
- PHYSICIAN
Narratives
NO HOSPITAL/MEDICAL RECORDS HAVE BEEN MADE AVAILABLE TO THE MANUFACTURER. AS THE LOT NUMBER FOR THE DEVICE WAS NOT PROVIDED, A REVIEW OF THE DEVICE HISTORY RECORDS WILL NOT BE PERFORMED. THE DEVICE HAS NOT BEEN RETURNED TO THE MANUFACTURER FOR EVALUATION. THE INVESTIGATION OF THE REPORTED EVENT IS CURRENTLY UNDERWAY. ARTICLE REVIEW: A SURGICAL BYPASS GRAFT WAS IMPLANTED IN A DIABETIC PATIENT WITH A HISTORY OF LEFT CRITICAL LIMB ISCHEMIA AND NECROTIC FOOT ULCERS WITH PRIOR OCCLUSION OF THE SUPERFICIAL FEMORAL ARTERY SEGMENT. THE PATIENT HAD A LEFT EXTERNAL ILIAC TO ABOVE KNEE POPLITEAL BYPASS WITH A POLYTETRAFLUOROETHYLENE GRAFT ALONG WITH FIRST AND SECOND TOE AMPUTATION. AS A RESULT OF THE OCCLUSION, BALLOON ANGIOPLASTY WAS PERFORMED. COMPLETION ANGIOGRAPHY DEMONSTRATED FULL REVASCULARIZATION OF THE SUPERFICIAL FEMORAL ARTERY WITH RAPID FLOW INTO THE BELOW KNEE VESSELS. HUSAINY, M.A., SLIM, H., RASHID, H., HUANG, D.Y. (2017). RECANALISATION OF CHRONICALLY OCCLUDED REMOTE SUPERFICIAL FEMORAL ARTERY ENDARTERECTOMY THROUGH ANGIOPLASTY FOR LIMB SALVAGE. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 40, 302-305. DOI: 10.1007/S00270-016-1499-7. THE INFORMATION PROVIDED BY BARD REPRESENTS ALL OF THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BARD.
MANUFACTURING REVIEW: AS THE LOT NUMBER FOR THE DEVICE WAS NOT PROVIDED, A MANUFACTURING REVIEW COULD NOT BE PERFORMED. ARTICLE REVIEW: A SURGICAL BYPASS GRAFT WAS IMPLANTED IN A DIABETIC PATIENT WITH A HISTORY OF LEFT CRITICAL LIMB ISCHEMIA AND NECROTIC FOOT ULCERS WITH PRIOR OCCLUSION OF THE SUPERFICIAL FEMORAL ARTERY SEGMENT. THE PATIENT HAD A LEFT EXTERNAL ILIAC TO ABOVE KNEE POPLITEAL BYPASS WITH A POLYTETRAFLUOROETHYLENE GRAFT ALONG WITH FIRST AND SECOND TOE AMPUTATION. AS A RESULT OF THE OCCLUSION, BALLOON ANGIOPLASTY WAS PERFORMED. COMPLETION ANGIOGRAPHY DEMONSTRATED FULL REVASCULARIZATION OF THE SUPERFICIAL FEMORAL ARTERY WITH RAPID FLOW INTO THE BELOW KNEE VESSELS. HUSAINY, M.A., SLIM, H., RASHID, H., HUANG, D.Y. (2017). RECANALISATION OF CHRONICALLY OCCLUDED REMOTE SUPERFICIAL FEMORAL ARTERY ENDARTERECTOMY THROUGH ANGIOPLASTY FOR LIMB SALVAGE. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 40, 302-305. DOI: 10.1007/S00270-016-1499-7. INVESTIGATION SUMMARY: THE DEVICE WAS NOT RETURNED FOR EVALUATION. HOWEVER, AN IMAGE WAS PROVIDED FOR REVIEW. IMAGING COULD IDENTIFY SIX RADIOPAQUE DENSITIES OF ARTERIAL FLOW IN THE RIGHT LEG AND APPROXIMATELY FOUR RADIOPAQUE DENSITIES OF ARTERIAL FLOW ON THE LEFT LEG. THE ALLEGED IMPLANTED GRAFT COULD NOT BE IDENTIFIED BASED ON THE PROVIDED IMAGE. THEREFORE, THE INVESTIGATION IS INCONCLUSIVE FOR THE ALLEGED OCCLUSION. BASED UPON THE AVAILABLE INFORMATION, THE DEFINITIVE ROOT CAUSE IS UNKNOWN. LABELING REVIEW: THE CURRENT IFU (INSTRUCTIONS FOR USE) STATES: ADVERSE REACTIONS POTENTIAL COMPLICATIONS WHICH MAY OCCUR WITH ANY SURGICAL PROCEDURE INVOLVING A VASCULAR PROSTHESIS INCLUDE, BUT ARE NOT LIMITED TO: DISRUPTION OR TEARING OF THE SUTURE LINE, GRAFT, AND/OR HOST VESSEL; SUTURE HOLE BLEEDING; GRAFT REDUNDANCY; THROMBOSIS, EMBOLIC EVENTS, OCCLUSION OR STENOSIS; ULTRAFILTRATION; SEROMA FORMATION; SWELLING OF THE IMPLANTED LIMB; FORMATION OF HEMATOMA OR PSEUDOANEURYSM; INFECTION; ANEURYSM/DILATION; BLOOD LEAKAGE; HEMORRHAGE; STEAL SYNDROME; AND/OR SKIN EROSION.
IT WAS REPORTED IN AN ARTICLE IN CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY TITLED "RECANALISATION OF CHRONICALLY OCCLUDED REMOTE SUPERFICIAL FEMORAL ARTERY ENDARTERECTOMY THROUGH ANGIOPLASTY FOR LIMB SALVAGE", FOLLOWING GRAFT INPLANTATION, THE EPTFE GRAFT OCCLUDED POST FOUR MONTHS IMPLANT. BALLOON ANGIOPLASTY WAS PERFORMED AND FULL REVASCULARIZATION WITH RAPID FLOW WAS ACHIEVED.
IT WAS REPORTED IN AN ARTICLE IN CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY TITLED "RECANALISATION OF CHRONICALLY OCCLUDED REMOTE SUPERFICIAL FEMORAL ARTERY ENDARTERECTOMY THROUGH ANGIOPLASTY FOR LIMB SALVAGE", FOLLOWING GRAFT IMPLANTATION, THE EPTFE GRAFT OCCLUDED POST FOUR MONTHS INPLANT. BALLOON ANGIOPLASTY WAS PERFORMED AND FULL REVASCULARIZATION WITH RAPID FLOW WAS ACHIEVED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 5764 | DISTAFLO BYPASS GRAFT | VASCULAR GRAFT | DSY | BARD PERIPHERAL VASCULAR, INC. | UNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 64 YR | Required Intervention |