FDA Adverse Event Malfunction Summary report: N

8031673-2017-00180

MDR report key: 7124252 · Received December 15, 2017

Report

Report Number
8031673-2017-00180
Event Type
Malfunction
Date Received
December 15, 2017
Date of Event
November 16, 2017
Report Date
April 5, 2018
PMA / PMN Number
K971103
Removal / Correction Number
3005529799-2/21/18-004-R
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NE, US
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

ADDITIONAL MANUFACTURER NARRATIVE: TOSOH BIOSCIENCE, INC. IS SUBMITTING ON BEHALF OF THE FOREIGN MANUFACTURER, TOSOH CORPORATION, PER EXEMPTION NUMBER E2017013. DEVICE EVALUATION BY MANUFACTURER: CONCLUSION NOT YET AVAILABLE; INVESTIGATION IS CURRENTLY IN PROCESS.

Description of Event or Problem · 0

ON (B)(6) 2017 A CUSTOMER REPORTED THAT ON (B)(6) 2017 A HEMOGLOBIN A1C (HBA1C) PATIENT SAMPLE OBTAINED AN INITIAL RESULT OF 7.1% (ASSAY RANGE IS 3.8 - 6.0 %) AND THE PHYSICIAN QUESTIONED THE RESULT BECAUSE THEIR POINT OF CARE INSTRUMENT HAD A RESULT OF 5.5%. THE PHYSICIAN REPORTED THAT THE 5.5% RESULT CORRELATED WITH THE PATIENT'S CLINICAL HISTORY. ON (B)(6) 2017 THE PATIENT WAS REDRAWN AND RAN ON THE AIA-900 INSTRUMENT TWICE WITH RESULTS OF 6.5% AND 6.2%. THE CUSTOMER SENT OUT THE PATIENT SAMPLE TO A REFERENCE LAB, WHICH OBTAINED A RESULT OF 6.0%. THE CUSTOMER REPORTED THAT QUALITY CONTROLS WERE WITHIN RANGE. THERE IS NO INDICATION OF ANY PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THIS EVENT THE SUBJECT SAMPLE WAS SENT TO TOSOH BIOSCIENCE FOR INVESTIGATION BY THE QUALITY ASSURANCE LAB.

Additional Manufacturer Narrative · 1

(B)(4) PER EXEMPTION NUMBER E2017013. DEVICE EVALUATION BY MANUFACTURER: INVESTIGATION INTO THIS ISSUE BY TOSOH HAS DETERMINED THAT THE ST AIA-PACK HBA1C ASSAY CAN POTENTIALLY GENERATE ERRONEOUSLY ELEVATED OR ERRONEOUSLY DECREASED HBA1C PATIENT RESULTS ON THE AIA SYSTEMS. THE INVESTIGATION CONFIRMED INCONSISTENT OR UNEXPECTED VARIABILITY OF HBA1C RESULTS WHEN COMPARING TOSOH'S ST AIA-PACK HBA1C TO ALTERNATIVE HBA1C TESTING. RISK TO HEALTH: A FALSELY ELEVATED OR FALSELY LOW HBA1C RESULT MAY NOT BE EASILY RECOGNIZED WHEN THERE IS NO PATIENT HISTORY OR CLINICAL PICTURE, WHICH WOULD INDICATE THAT AN INCORRECT TEST RESULT WAS OBTAINED. IN CURRENT MEDICAL PRACTICE, SINGLE HBA1C BLOOD MEASUREMENTS ARE THE PRIMARY INDICATOR OF THE DEGREE OF SUSTAINED GLYCEMIC CONTROL AND IT IS NOT CURRENT PRACTICE TO CORROBORATE A BLOOD HBA1C RESULT ON AN ALTERNATIVE SYSTEM. DEVICE FAILURE MAY BE EASILY RECOGNIZED GIVEN A PATIENT HISTORY OR CLINICAL PICTURE, WHICH IS NOT CONSISTENT WITH THE REPORTED RESULT, WHICH IS MOST LIKELY TO OCCUR UNDER A RIGOROUS AND ROUTINE MEDICAL CARE OR IN A HOSPITAL SETTING, SUCH AS AN INTENSIVE CARE UNIT, WHERE INTENSE CLINICAL OBSERVATION OCCURS. HOWEVER, BECAUSE HBA1C LEVELS ARE EXTENSIVELY USED IN THE OUTPATIENT SETTING AT WIDE TIME INTERVALS AS THE SINGLE RELIABLE TEST TO MONITOR GLYCEMIC CONTROL, DEVICE FAILURE IS NOT EASILY RECOGNIZED BY THE USER IN THIS SETTING. THE AMERICAN DIABETES ASSOCIATION (ADA) RECOMMENDS MEASUREMENT OF HBA1C (TYPICALLY 3-4 TIMES PER YEAR FOR TYPE 1 AND POORLY CONTROLLED TYPE 2 DIABETIC PATIENTS, AND 2 TIMES PER YEAR FOR WELL-CONTROLLED TYPE 2 DIABETIC PATIENTS) TO DETERMINE WHETHER A PATIENT'S GLYCEMIC METABOLIC CONTROL HAS REMAINED CONTINUOUSLY WITHIN THE TARGET RANGE. IMMEDIATE HEALTH CONSEQUENCES OF A FALSELY LOW OR FALSELY NORMAL HBA1C RESULT INCLUDE THE FAILURE OF THE HEALTHCARE PRACTITIONER TO RECOGNIZE VERY POOR AND DETERIORATING GLYCEMIC CONTROL IN KNOWN DIABETICS WHO ARE NOT YET IN A STATE OF KETOACIDOSIS, WITH THE RESULTING CONSEQUENCE OF THE SUBSEQUENT DEVELOPMENT OF LIFE-THREATENING DIABETIC KETOACIDOSIS. LONG-RANGE HEALTH CONSEQUENCES OF FALSELY LOW OR FALSELY NORMAL HBA1C LEVELS INCLUDE THE FAILURE TO RECOGNIZE AND MANAGE INADEQUATE GLYCEMIC CONTROL WITH THE CONSEQUENCES OF LONG-RANGE RISKS FOR BOTH THE INDIVIDUAL PATIENT AND THE PUBLIC HEALTH. THESE RISKS OF SUSTAINED POOR GLYCEMIC CONTROL FOR THE INDIVIDUAL DIABETIC AND THE PUBLIC HEALTH INCLUDE THE DEVELOPMENT OF DIABETIC NEUROPATHY (INCLUDING AMPUTATION); RETINOPATHY (INCLUDING BLINDNESS); DIABETIC RENAL DISEASE (INCLUDING END STAGE RENAL FAILURE AND NEED FOR DIALYSIS), AND MACRO-VASCULAR DISEASE (INCLUDING CARDIOVASCULAR EVENTS). IMMEDIATE AND LONG-TERM HEALTH CONSEQUENCES OF FALSELY ELEVATED HBA1C LEVELS INCLUDE THE UNNECESSARY ADDITION OF POTENT GLUCOSE-LOWERING DRUGS OR THE UNNECESSARY INCREASE IN DRUG DOSAGE IN KNOWN DIABETICS, WITH THE RISK OF HYPOGLYCEMIA, INCLUDING THE LIFE-THREATENING RISK OF COMA AND LOSS OF CONSCIOUSNESS AS WELL AS OTHER DISABLING SYMPTOMS OF HYPOGLYCEMIA. HEALTH RISKS OF FALSELY LOW LEVELS ALSO INCLUDE THE RISK OF FAILURE TO DIAGNOSE DIABETES, AS WELL AS THE RISK OF FAILURE TO DIAGNOSE PATIENTS AT INCREASED RISK FOR DIABETES (PREDIABETES). IN ORDER TO PREVENT ANY RISK TO HEALTH, TOSOH HAS TAKEN THE FOLLOWING ACTIONS: IMMEDIATE ACTIONS TO BE TAKEN BY THE CUSTOMER: IMMEDIATELY DISCONTINUE USE OF ALL LOT NUMBERS OF THE ST AIA-PACK HBA1C TEST AND COMPONENTS. IMMEDIATELY REMOVE ALL ST AIA-PACK HBA1C TEST AND COMPONENTS MATERIALS/KITS FROM THEIR INVENTORY. REVIEW THE INFORMATION PROVIDE BY TOSOH WITH THE MEDICAL DIRECTOR AND/OR LAB DIRECTOR. IMMEDIATELY NOTIFY AND FORWARD THIS INFORMATION TO PHYSICIANS WHO HAVE RECEIVED TEST RESULTS THAT HAD BEEN PROVIDED BY THE RECALLED PRODUCTS OVER THE PAST 6 MONTHS SO THAT THEY MAY DETERMINE IF FOLLOW-UP TESTING IS REQUIRED (E.G. IF THE HBA1C RESULTS THEY RECEIVED DID NOT MATCH OTHER PATIENT DATA SUCH AS SYMPTOMS, RESULTS OF OTHER TESTS (TYPICALLY BLOOD GLUCOSE LEVELS), OR CLINICAL IMPRESSIONS, OR RESULTS WHICH SHOWED INCONSISTENT TEST VALUES) IMMEDIATELY IDENTIFY AN ALTERNATIVE TEST OPTION FOR YOUR HBA1C TESTING NEEDS. TOSOH IS PERMANENTLY REMOVING THE ST AIA-PACK HBA1C TEST AND COMPONENTS FROM THE MARKET. TOSOH ROOT CAUSE INVESTIGATION DETERMINED THAT INDUSTRY STANDARDS AND EXPECTATIONS OF PERFORMANCE HAVE CHANGED SINCE THE INTRODUCTION OF THE ST AIA-PACK HBA1C ASSAY. IN ORDER FOR THE ASSAY TO BE USEFUL, IT WOULD BE NECESSARY TO REDUCE LOT TO LOT VARIABILITY OF REAGENT TO WELL BELOW 6% TO ALLOW FOR HUMAN FACTORS; TOSOH'S RELEASE SPECIFICATION IS +/- 10%. THE ROOT CAUSE INVESTIGATION CONFIRMED THAT THE ST AIA-PACK HBA1C EXHIBITS LOT TO LOT VARIABILITY WITHIN THE +/- 10%. THE ST AIA-PACK HBA1C RESULTS ARE INFLUENCED BY A NUMBER OF FACTORS, INCLUDING OPERATOR SKILLS AND SPECIMEN QUALITY, WHICH MAY INCREASE VARIABILITY. TOSOH ST AIA-PACK HBA1C CANNOT MEET CURRENT REQUIREMENTS.

Description of Event or Problem · 1

N/A.

Patients

Seq Age Sex Outcome Treatment
1