PULSE-GENERATOR, PACEMAKER, IMPLANTABLE
Report
- Report Number
- 2182208-2017-01902
- Event Type
- Injury
- Date Received
- December 7, 2017
- Date of Event
- November 27, 2016
- Report Date
- February 8, 2018
- Manufacturer
- MEDTRONIC, INC.
- Product Code
- DXY
- PMA / PMN Number
- P010031
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AS
- Reporter Occupation
- HEALTH PROFESSIONAL
Narratives
THIS INFORMATION IS BASED ENTIRELY ON JOURNAL LITERATURE. ALL INFORMATION PROVIDED IS INCLUDED IN THIS REPORT. MULTIPLE PATIENTS WERE NOTED IN THE ARTICLE; HOWEVER, A ONE TO ONE CORRELATION COULD NOT BE MADE WITH UNIQUE DEVICE SERIAL NUMBERS. SINCE NO DEVICE ID WAS PROVIDED, IT IS UNKNOWN IF THIS EVENT HAS BEEN PREVIOUSLY REPORTED. POSSIBLE MODELS INCLUDE THE MAXIMO ICD. REQUEST FOR ADDITIONAL INFORMATION WILL BE MADE AND UPON RECEIPT A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY. REFERENCED ARTICLE:A REVIEW OF IMPLANTABLE CARDIOVERTER DEFIBRILLATOR FAILURES DURING RADIATION THERAPY IN THREE (B)(6) HOSPITALS. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY. 2017; 61(4):517-521. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
A JOURNAL ARTICLE WAS REVIEWED WHICH CONTAINED INFORMATION REGARDING IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) FAILURES DURING RADIATION THERAPY. MULTIPLE PATIENTS WERE NOTED IN THE ARTICLE; HOWEVER, A ONE TO ONE CORRELATION COULD NOT BE MADE WITH UNIQUE DEVICE SERIAL NUMBERS. THE ARTICLE REPORTS THAT ONE PATIENT EXPERIENCED A POWER ON RESET (POR) DURING THE FINAL ROUND OF RADIATION THERAPY. THE ICD WAS REPROGRAMMED AND REMAINED IN USE. FURTHER FOLLOW UP DID NOT YET YIELD ANY ADDITIONAL INFORMATION. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
FOLLOW UP INFORMATION RECEIVED FROM THE AUTHOR INDICATED THERE ARE NO ADDITIONAL COMPLAINTS AND NO INFORMATION ON PRODUCT SERIAL NUMBERS. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 870653 | PULSE-GENERATOR, PACEMAKER, IMPLANTABLE | DXY | MEDTRONIC, INC. | MDT-ICD |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 80 YR | Required Intervention |