SURGICEL ABSORBABLE HEMOSTAT
Report
- Report Number
- 2210968-2017-71488
- Event Type
- Injury
- Date Received
- November 29, 2017
- Report Date
- November 3, 2017
- Manufacturer
- ETHICON INC.
- Product Code
- LMF
- PMA / PMN Number
- N12159
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- OH, US
- Reporter Occupation
- OTHER
Narratives
(B)(4). ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT PRODUCTS INVOLVED CAUSED AND/OR CONTRIBUTED TO SYMPTOMS OF BLEEDING, INFECTION, AND RENAL INEFFICIENCY DESCRIBED IN THE ARTICLE? IF YES, PROVIDE DETAILS OF EVENT AND SPECIFIC PRODUCT CODE. CAN SPECIFIC PATIENT DEMOGRAPHICS BE PROVIDED FOR EACH OF THE SUBJECTS OF THIS ARTICLE? IF YES, PLEASE INCLUDE: DATE AND TYPE OF PROCEDURE, WHERE PROCEDURE WAS PERFORMED, SPECIFIC MEDICAL/SURGICAL INTERVENTION PER PATIENT, PRODUCT INVOLVED, PRE-EXISTING CONDITIONS. ARE THE PRODUCT CODE AND LOT NUMBERS AVAILABLE FOR DEVICES USED? TO DATE THE DEVICE HAS NOT BEEN RETURNED. IF THE DEVICE OR FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. CITATION: EUROPEAN UROLOGY 2006; 49:660-665. DOI:10.1016/J.EURURO.2006.02.001.
IT WAS REPORTED IN A JOURNAL ARTICLE (LAPAROSCOPIC PARTIAL NEPHRECTOMY: CONTEMPORARY TECHNIQUE AND OUTCOMES) THAT THE PATIENT UNDERWENT A LAPAROSCOPIC PARTIAL NEPHRECTOMY. IN THE SURGICAL TECHNIQUE, THE COLLECTING SYSTEM IS SUTURE REPAIRED WITH A RUNNING SUTURE ON NEEDLE. RENAL PARENCHYMAL REPAIR IS PERFORMED WITH 1-0 POLYGLACTIN ON A GS-25 NEEDLE. THREE TO 5 INTERRUPTED SUTURES ARE PLACED OVER A PRE-PREPARED ABSORBABLE HEMOSTAT BOLSTER THAT HAS BEEN POSITIONED OVER THE CUT SURFACE OF THE KIDNEY. FLOSEAL IS APPLIED TO THE CUT RENAL PARENCHYMAL SURFACE UNDERNEATH THE BOLSTER. ANOTHER HEM-O-LOK CLIP IS APPLIED TO THE SUTURE FLUSH WITH THE OPPOSITE RENAL SURFACE, COMPRESSING THE KIDNEY. THE SUTURE IS THEN TIGHTLY TIED ACROSS THE BOLSTER, MAINTAINING ADEQUATE PARENCHYMAL COMPRESSION. POSTOPERATIVELY, THE PATIENT MAY HAVE EXPERIENCED BLEEDING, RENAL INSUFFICIENCY, AND INFECTION. TREATMENT OF THE EVENT WAS NOT REPORTED. ADDITIONAL INFORMATION HAS BEEN REQUESTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 847853 | SURGICEL ABSORBABLE HEMOSTAT | HEMOSTATIC AGENT, ABSORBABLE | LMF | ETHICON INC. | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |