VITEK® 2 AST-YS08 TEST KIT
Report
- Report Number
- 1950204-2017-00401
- Event Type
- Malfunction
- Date Received
- November 20, 2017
- Report Date
- May 11, 2018
- Manufacturer
- BIOMERIEUX, INC
- Product Code
- NGZ
- PMA / PMN Number
- K133817
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FR
- Reporter Occupation
- HEALTH PROFESSIONAL
Narratives
THIS REPORT WAS INITIALLY SUBMITTED IN RESPONSE TO A CUSTOMER IN (B)(6) REPORTING FALSE INTERMEDIATE FLUCONAZOLE RESULTS FOR A CANDIDA NORVEGENSIS EXTERNAL QUALITY CONTROL (EEQ) STRAIN IN ASSOCIATION WITH THE VITEK® 2 AST-YS08 TEST KIT. THE RESULT WAS FLUCONAZOLE : MIC = 16, INTERMEDIATE. THE EXPECTED RESULT WAS RESISTANT. AN INTERNAL BIOMÉRIEUX INVESTIGATION WAS PERFORMED THAT INCLUDED TESTING FOR BOTH FLUCONAZOLE (FLU) AND FLUCYTOSINE (FCT) RESULTS WITH A STRAIN OF CANDIDA NORVEGENSIS ON VITEK® 2 AST-YS08 CARDS. THIS STRAIN IS FROM A BIOLOGIE PROSPECTIVE SURVEY (MYCOLOGY 2017- SAMPLE 3A). ID TESTING : IDENTIFICATION WAS CONFIRMED TO CANDIDA NORVEGENSIS ON VITEK 2 YST ID CARD (LOT 2430356103). AST TESTING: · REFERENCE METHOD TO DETERMINE THE INTENDED RESULT FOR FLUCONAZOLE AND FLUCYTOSINE: BROTH MICRODILUTION, METHOD USED TO DEVELOP THE FORMULARIES "FLU02N" / "FCT02N" (IN AST-YS08 CARD). · FLU MIC = 16 MG/L INTERMEDIATE · FCT MIC = 8 MG/L INTERMEDIATE INTERPRETATION ACCORDING TO VITEK 2 BREAKPOINTS IN V7.01 : FDA 2009 BREAKPOINTS FOR CANDIDA / FLUCONAZOLE S </=8 - I 16-32 - R >/=64. FDA 2012 BREAKPOINTS FOR CANDIDA / FLUCYTOSINE : S </=4 - I 8-16 - R >/=32. NOTE: FOR ANTIFUNGALS, ESSENTIAL AGREEMENT BETWEEN VITEK® 2 CARD AND REFERENCE METHOD MICS IS +/- 2 DOUBLING DILUTIONS. · PRODUCTS & SYSTEM INCRIMINATED: -AST -YS08 ON VITEK 2 V7.01 THREE (3) VITEK 2 AST-YS08 LOTS WERE TESTED FROM SABOURAUD DEXTROSE AGAR (SDA). VITEK 2 GAVE THE FOLLOWING RESULTS ON THE THREE (3) LOTS TESTED: **FLU MIC = 8 MG/L SUSCEPTIBLE **FCT MIC = 4 MG/L SUSCEPTIBLE THE VITEK 2 RESULTS ARE WITHIN ESSENTIAL AGREEMENT WITH THE REFERENCE MIC WITHIN +/- 1 DOUBLING DILUTION. CONCLUSION: -THE CUSTOMER RESULTS WERE DUPLICATED ON THE AST-YS08 CARDS (MIC FLU= 8 MG/L S AND FCT MIC=4 MG/L S). -THE VITEK 2 AST-YS08 CARDS PERFORM AS INTENDED. THE VITEK 2 VALUES ARE WITHIN ESSENTIAL AGREEMENT WITH THE REFERENCE RESULTS OBTAINED IN BMD. -THE REFERENCE MIC FOR BOTH FLUCONAZOLE AND FLUCYTOSINE ARE IN THE MIDDLE OF THE BREAKPOINTS, SO THE STRAIN CAN BE SUSCEPTIBLE OR RESISTANT WITHIN +/- 2 DOUBLING DILUTIONS. -->BORDERLINE STRAIN.
A CUSTOMER IN (B)(6) REPORTED FALSE SUSCEPTIBLE FLUCYTOSINE RESULTS AND FALSE INTERMEDIATE FLUCONAZOLE RESULTS FOR A CANDIDA NORVEGENSIS EXTERNAL QUALITY CONTROL (EEQ) STRAIN IN ASSOCIATION WITH THE VITEK® 2 AST-YS08 TEST KIT. THE RESULTS WERE: FLUCYTOSINE : MIC = 4 SUSCEPTIBLE. THE EXPECTED RESULT WAS RESISTANT. FLUCONAZOLE : MIC = 16, INTERMEDIATE. THE EXPECTED RESULT WAS RESISTANT. THERE WAS NO PATIENT INVOLVEMENT AS THE EVENT PERTAINED TO AN EXTERNAL QUALITY CONTROL SAMPLE. AN INVESTIGATION WILL BE INITIATED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 824840 | VITEK® 2 AST-YS08 TEST KIT | VITEK® 2 AST-YS08 TEST KIT | NGZ | BIOMERIEUX, INC | 2880150203 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |