FDA Adverse Event Malfunction Summary report: N

UNK SG3

MDR report key: 7033279 · Received November 15, 2017

Report

Report Number
3003902955-2017-00038
Event Type
Malfunction
Date Received
November 15, 2017
Report Date
November 15, 2017
Manufacturer
TERUMO PHILIPPINES CORPORATION
Product Code
MEG
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
TX, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

THE ACTUAL DEVICE WAS NOT RETURNED FOR EVALUATION AND THE PRODUCT CODE AND LOT ARE UNKNOWN. NO EVALUATION COULD BE CONDUCTED DUE TO THE DEVICE NOT BEING RETURNED. THERE IS NO EVIDENCE THAT THIS EVENT WAS RELATED TO A DEVICE DEFECT OR MALFUNCTION. WITH NO DEVICE RETURN THE EXACT CAUSE OF THE REPORTED EVENT CANNOT BE DEFINITIVELY DETERMINED BASED ON THE AVAILABLE INFORMATION. THE PRODUCTION LOT NUMBER WAS NOT PROVIDED BY THE USER FACILITY, WHICH PREVENTED A MEANINGFUL REVIEW OF THE DEVICE HISTORY RECORD AND COMPLAINT FILES. PRIOR TO SHIPMENT, QC CONDUCTS OUTGOING VISUAL INSPECTION AND ALL SAMPLES FOR THE COMPLAINT LOT PASSED. THE SAME USER FACILITY REPORTED SIMILAR EVENTS FOR OTHER DEVICES. SEE MDR 3003902955-2017-00033, 3003902955-2017-00034, AND 3003902955-2017-00037. TERUMO MEDICAL PRODUCTS (TMP) (IMPORTER) REGISTRATION NO. 2243441 IS SUBMITTING THIS REPORT ON BEHALF OF TERUMO (PHILIPPINES) CORPORATION (MANUFACTURER) REGISTRATION NO. 3003902955. EXEMPTION NUMBER E2015017.

Description of Event or Problem · 0

A DISTRIBUTOR REPORTED A NEEDLE STICK INCIDENTS BY A NEWLY CONVERTED CUSTOMER. IT WAS REPORTED DIFFICULTY WITH ACTIVATING THE SAFETY NEEDLE COVER OF THE TERUMO SURGUARD 3 SAFETY NEEDLE. IT WAS REPORTED THAT IT IS DIFFICULT TO GET THE COVER TO CLOSE OVER THE NEEDLE AND ONE COMPLAINT SPECIFICALLY CITED DIFFICULTY WITH THUMB ACTIVATION OF THE NEEDLE COVER. NO KNOWN IMPACT TO THE PATIENT. ADDITIONAL INFORMATION RECEIVED ON (B)(6) 2017. WE HAVE NOW HAD OUR FOURTH NEEDLE STICK IN THE PAST MONTH ASSOCIATED WITH FLU SHOT ADMINISTRATION. THE INJURED PERSON IN THE INCIDENT YESTERDAY SPECIFICALLY CITED DIFFICULTY WITH CLOSING THE SAFETY NEEDLE COVER ON THE TERUMO SURGUARD3 SAFETY NEEDLE AS CONTRIBUTING TO THE INCIDENT. IT WAS REPORTED THAT IN MOST CASES IT WAS INATTENTION AND ERRORS IN TECHNIQUE ARE PRIMARILY TO BLAME FOR THESE NEEDLE STICKS. IT WAS REPORTED THAT THE NEEDLE COVER IS VERY DIFFICULT TO CLOSE AND PROPERLY ENGAGE OVER THE NEEDLE AFTER USE. IT WAS REPORTED THAT A LOT OF THIS IS ADAPTATION TO A NEW PRODUCT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
814149 UNK SG3 SYRINGE, ANTISTICK MEG TERUMO PHILIPPINES CORPORATION N/A UNK

Patients

Seq Age Sex Outcome Treatment
1