FDA Adverse Event Malfunction Summary report: N

TORNADO

MDR report key: 6939914 · Received October 11, 2017

Report

Report Number
3007420694-2017-00207
Event Type
Malfunction
Date Received
October 11, 2017
Date of Event
September 10, 2017
Report Date
November 29, 2017
Manufacturer
GETINGE DISINFECTION AB
Product Code
FLH
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
GM
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

PLEASE NOTE THAT PREVIOUS MEDWATCH REPORTS FOR THIS PRODUCT MAY HAVE BEEN SUBMITTED FOR GETINGE DISINFECTION AB, SWEDEN (REGISTRATION #9616031) ON BEHALF OF IMPORTER GETINGE USA, INC (REGISTRATION #3004147784). FROM SEP 2017 AND GOING FORWARD COMPLAINTS RELATED TO THESE PRODUCTS ARE TO BE HANDLED BY ARJOHUNTLEIGH POLSKA SP. Z O. O. (REGISTRATION #3007420694). THE MEDWATCH REPORTS ARE TO BE FILLED AND SUBMITTED UNDER EXEMPTION E2012070 BY THE MANUFACTURER ARJOHUNTLEIGH POLSKA SP. Z O. O. (REGISTRATION #3007420694) ON BEHALF OF THE IMPORTER ARJOHUNTLEIGH, INC. (AHUS) (REGISTRATION #1419652). ADDITIONAL INFORMATION WILL BE PROVIDED UPON CONCLUSION OF THE INVESTIGATION.

Additional Manufacturer Narrative · 0

PLEASE NOTE THAT PREVIOUS MEDWATCH REPORTS FOR THIS PRODUCT MAY HAVE BEEN SUBMITTED FOR GETINGE DISINFECTION AB, SWEDEN (REGISTRATION #9616031) ON BEHALF OF IMPORTER GETINGE USA, INC (REGISTRATION #3004147784). FROM SEP 2017 AND GOING FORWARD COMPLAINTS RELATED TO THESE PRODUCTS ARE TO BE HANDLED BY ARJOHUNTLEIGH POLSKA SP. Z O. O. (REGISTRATION #3007420694). THE MEDWATCH REPORTS ARE TO BE FILLED AND SUBMITTED UNDER EXEMPTION E2012070 BY THE MANUFACTURER ARJOHUNTLEIGH POLSKA SP. Z O. O. (REGISTRATION #3007420694) ON BEHALF OF THE IMPORTER ARJOHUNTLEIGH, INC. (AHUS) (REGISTRATION #1419652). AN INVESTIGATION WAS CARRIED OUT INTO THIS COMPLAINT. ON 2017-SEP-11 ARJOHUNTLEIGH WAS INFORMED ABOUT THE INCIDENT INVOLVING TORNADO FLUSHER. FOLLOWING THE INFORMATION REPORTED THE OPEN FIRE WAS FOUND INSIDE THE FLUSHER AND A SMOKE DEVELOPMENT TRIGGERED ACTIVATION OF A SMOKE ALARM IN ONE OF THE CUSTOMER FACILITY ROOMS. THE FIRE WAS EXTINGUISHED WITH EXTINGUISHING FOAM AND PEOPLE FROM THE CUSTOMER FACILITY WERE EVACUATED. THERE WAS NO INJURY SUSTAINED IN RELATION TO THIS EVENT. THE PHOTOGRAPHIC EVIDENCE PROVIDED WITHIN THE COMPLAINT ALLOWED US TO ESTABLISH THAT THE ELECTRICAL COMPONENT PLUGGED INTO THE STEAM GENERATOR BECAME DAMAGED DUE TO FIRE EXPOSURE. ACCORDING TO ARJOHUNTLEIGH REPRESENTATIVE OPINION, THE FIRE WAS PROBABLY TRIGGERED BY THE PLUG CONNECTOR ON THE STEAM GENERATOR. FURTHER VISUAL INSPECTION REVEALED THAT THE FLUSHER WAS IN GENERAL GOOD CONDITION EXCEPT FROM THE CONNECTOR AND THE ADJACENT PART OF STEAM GENERATOR CABLE. AT THE TIME, THE INSPECTION WAS PERFORMED - THE DEVICE WAS NOT FUNCTIONING AT ALL. IT NEEDS TO BE EMPHASIZED THAT THE DEVICE IN QUESTION WAS UNDER ARJOHUNTLEIGH SERVICE CONTRACT, PREVENTIVE MAINTENANCE CHECK WAS PROVIDED REGULARLY - THE LAST ONE WAS PERFORMED IN JULY 2017. DURING THAT INSPECTION, THE FUNCTIONAL TEST WAS PERFORMED- NO DEVIATIONS WERE FOUND. ALL ELECTRICAL COMPONENTS HAVE BEEN VISUALLY CHECKED DURING EACH PREVENTIVE MAINTENANCE (PM) AND THE STEAM GENERATOR WAS REMOVED AND CLEANED INSIDE MINIMUM ONCE A YEAR. IT NEEDS TO BE EMPHASIZED THAT THE FLUSHER WAS TESTED ACCORDING TO DGUV VORSCHRIFT 3 (THE ELECTRICAL SAFETY TEST, WHICH HAS TO BE PERFORMED AS A RECURRENT TEST AND AFTER REPAIR OF MEDICAL ELECTRICAL EQUIPMENT ACCORDING TO EN62353) AND THE FACILITY CUSTOMER USED THE RESIDUAL CURRENT DEVICE (RDC) WITH EVERY FLUSHER. A RDC IS DESIGNED TO DISCONNECT A CIRCUIT WHEN AN ELECTRIC LEAKAGE OCCURS AND PREVENT FROM ELECTRIC SHOCK OR BURNS OF WIRE INSOLATION. A COMPREHENSIVE ROOT CAUSE ANALYSIS WAS PERFORMED TO INVESTIGATE THIS PROBLEM. FROM THE ANALYSIS OF THE INVESTIGATED ISSUE, WE CANNOT DEFINE THE EXACT ROOT CAUSE. THIS PARTICULAR DEVICE WAS IN USE FOR 20 YEARS WHEN THE EVENT OCCURRED. TAKING INTO ACCOUNT THE ENVIRONMENT IN WHICH THE ELECTRICAL COMPONENTS RESIDED AND ITS AGE IT CAN BE STATED THAT THE FIRE WAS TRIGGERED AS A CONSEQUENCE OF ELECTRICAL COMPONENTS WEAR AND UNFORTUNATE COINCIDENCE. THE ELECTRICAL COMPONENTS INCLUDING WIRES, CONNECTOR PLUGS ARE EXCEPTIONALLY EXPOSED TO WEAR, WHAT IS INCREASED WITH WET AND WARM ENVIRONMENT INSIDE FLUSHER. IT NEEDS TO BE EMPHASIZED THAT THE PLASTIC INSULATION AND PLUG ARE VERY SUSCEPTIBLE TO AGING PROCESS WHAT MAKES THEM MORE STIFF, FRAGILE, BREAKABLE AND LESS RESISTANT TO EXTERNAL CONDITIONS. THE AGING PROCESS IS CAUSED BY ENVIRONMENTAL CONDITIONS, SUCH AS HIGH TEMPERATURE, EXPOSURE TO ULTRAVIOLET LIGHT, VISIBLE LIGHT, ATMOSPHERIC COMPONENTS, HUMIDITY OR LIQUIDS. AS PER TORNADO FLUSHER DESIGN, ALL INTERNAL PARTS ARE PLACED WITHIN THE METAL CABINET , WHICH IS A LIMITER FOR FIRE SPREAD. TO ENSURE THE SAFETY OF OUR PRODUCTS THE INSTRUCTIONS FOR USE PROVIDED TOGETHER WITH THE INVOLVED DEVICE INCLUDES THE FOLLOWING WARNING: WARNING: "IF THE MACHINE HAS NOT BEEN USED FOR 72 HOURS THE STEAM GENERATOR AND CIRCULATION PUMP MUST BE EMPTIED. THIS OPERATION MUST BE PERFORMED BY AUTHORIZED PERSONNEL." ADDITIONALLY, THE TECHNICAL MANUAL (502868500 REV. B) INFORMS THE FOLLOWING: INFORMATION: "CHECK THE FUSES AS FOLLOWS: SWITCH OFF THE MAIN SWITCH OF THE MACHINE. OPEN THE FRONT DOOR. REMOVE THE RELEVANT FUSE. CHECK THE FUSE WITH AN OHMMETER." INFORMATION: "INSTRUCTION MANUAL, CABLE, SWITCH CHECK THAT THE GOODS PLACING SIGN IS POSTED ON THE WALL BEHIND THE DISINFECTOR. CHECK THAT THE ISOLATOR SWITCH ON THE WALL IS WORKING AND THAT THE CONNECTING CABLE IS UNDAMAGED AND FREE FROM DEFECTS." WARNING: "WE RECOMMEND USING A RESIDUAL CURRENT DEVICE (RCD) WITH THE MACHINE." A REVIEW OF MDRS FOR THE LAST FIVE (5) YEARS (BY AWARENESS DATE SINCE 2012-SEP-25 TILL 2017-SEP-25) REVEALED NO REPORTABLE EVENTS RELATED TO THE REPORTED DEVICE PROBLEM. THEREFORE, WE CONSIDER THE REPORTED MALFUNCTION AS AN ISOLATED OCCURRENCE. ALTHOUGH THERE WERE NO INJURIES REPORTED, THE COMPLAINT WAS DECIDED TO BE REPORTABLE DUE TO INDICATION OF A FIRE OCCURRENCE. UPON THE CONDUCTED INVESTIGATION AND DEVICE INSPECTION DONE BY THE ARJOHUNTLEIGH REPRESENTATIVE, WE WERE ABLE TO DETERMINED THAT THE EVENT WAS CAUSED BY WEAR OF ELECTRICAL COMPONENTS, BUT WE WERE NOT ABLE TO ESTABLISH THE EXACT ROOT CAUSE AND SEQUENCE OF THE EVENTS WHICH HAVE LED TO THE ISSUE OCCURRENCE. BASED ON ALL ABOVE WE CONCLUDE THAT THE DEVICE WAS NOT WORKING UP TO MANUFACTURER'S SPECIFICATION.

Description of Event or Problem · 0

ON 2017-SEP-11 ARJOHUNTLEIGH WAS INFORMED ABOUT THE INCIDENT WITH REGARDS TO TORNADO FLUSHER. IN THE RECEIVED COMPLAINT, IT WAS REPORTED THAT OPEN FIRE IN THE FLUSHER WAS FOUND. AS A RESULT OF SMOKE DEVELOPMENT A SMOKE ALARM HAS BEEN TRIGGERED. THE FIRE WAS EXTINGUISHED WITH EXTINGUISHING FOAM AND STATION WAS EVACUATED. THERE WAS NO INJURY SUSTAINED. AFTER THE INCIDENT, THE DEVICE WAS INSPECTED BY ARJOHUNTLEIGH REPRESENTATIVE. FLUSHER WAS FOUND IN GENERAL GOOD CONDITION, ALTHOUGH THE FUNCTION TEST FAILED. THE DEVICE WAS UNDER ARJOHUNTLEIGH SERVICE CONTRACT. LAST PREVENTIVE MAINTENANCE WAS PERFORMED ON JULY 2017.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
719006 TORNADO WASHER OF BODY WASTE RECEPTACLES FLH GETINGE DISINFECTION AB SP1000AR001

Patients

Seq Age Sex Outcome Treatment
1 Other