FDA Adverse Event Injury Summary report: N

GORE® VIABAHN® ENDOPROSTHESIS

MDR report key: 6939712 · Received October 11, 2017

Report

Report Number
2017233-2017-00534
Event Type
Injury
Date Received
October 11, 2017
Date of Event
October 26, 2015
Report Date
November 23, 2017
Manufacturer
W.L. GORE & ASSOCIATES
Product Code
PFV
PMA / PMN Number
P040037
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
TW
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

ADD THE LITERUTURE AS ATTACHMENT. (B)(4) ADDITIONAL INFORMATION ABOUT THIS EVENT WAS REQUESTED BUT COULD NOT BE OBTAINED. WITHOUT ADDITIONAL INFORMATION IT IS IMPOSSIBLE TO FURTHER INVESTIGATE THIS EVENT. (B)(4).

Additional Manufacturer Narrative · 1

(B)(4). NO TESTING METHODS WERE PERFORMED SINCE NO PRODUCT INFORMATION WAS AVAILABLE.

Description of Event or Problem · 1

IN REVIEW OF PUBLISHED LITERATURE, THESE FINDINGS WERE NOTED: HUNG-LUNG HSU, CHEN-MING HUANG, YIN-YIN CHEN, FU-CHIEN HSIEH,AND JER-SHEN CHEN, ¿THE SANDWICH TECHNIQUE WITH BODY FLOSSING WIRE TO REVASCULARIZE LEFT SUBCLAVIAN ARTERY IN THORACIC ENDOVASCULAR AORTIC REPAIR¿, ANNALS OF VASCULAR SURGERY 2017; 39: 152¿159, HTTP://DX.DOI.ORG/10.1016/J.AVSG.2016.04.016. FROM APRIL 2014 TO APRIL 2015, 20 CONSECUTIVE PATIENTS (14 MALES AND 6 FEMALES, MEAN AGE 61.4) RECEIVING TEVAR FOR ACUTE OR CHRONIC THORACIC AORTIC PATHOLOGIES WHICH NEED COVERING THE LSA FOR ADEQUATE PROXIMAL LANDING WERE INCLUDED. ALL PATIENTS WERE IMPLANTED WITH GORE® VIABAHN® ENDOPROSTHESIS IN THE LEFT SUBCLAVIAN ARTERY AS PERISCOPE GRAFTS, 15 PATIENTS WITH ONLY ONE GRAFT AND FIVE PATIENTS WITH MORE THAN ONE GRAFT. SEVEN OF 20 PATIENTS WERE IMPLANTED WITH GORE® VIABAHN® ENDOPROSTHESIS IN THE LEFT COMMON CAROTID ARTERY (LCCA) AS CHIMNEY ENDOGRAFTS. TOTAL 19 PATIENTS HAD PATENT SANDWICHED GRAFTS. IT WAS STATED THAT THE PATENCY RATE OF THE SANDWICHED PERISCOPE GRAFT IN THE THORACIC AORTA WAS 95% AT A MEAN FOLLOW-UP OF 9.7 MONTHS. THE ONLY ONE (5%) OCCLUDED SANDWICHED PERISCOPE GRAFT WAS FOUND IN A (B)(6) FEMALE WITH CHRONIC STERNAL WOUND INFECTION AND RAPID EXPANSION OF RESIDUAL DESCENDING AORTIC DISSECTION AT 12-MONTH FOLLOW-UP AFTER REINTERVENTION FOR A TYPE IA ENDOLEAK. THIS LSA GRAFT MIGHT BE COMPRESSED OR KINKED DURING THE SECONDARY PROCEDURE BY THE KISSING BALLOON TECHNIQUE OVER THE LCCA CHIMNEY GRAFT AND THE EXTENDED PROXIMAL AORTIC ENDOGRAFT. NO NEUROLOGICAL DEFICIT OR LEFT UPPER LIMB ISCHEMIA WAS NOTED IN THE PATIENT AND THE OCCLUDED GRAFT WAS NOT ADDRESSED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
720366 GORE® VIABAHN® ENDOPROSTHESIS NIP PFV W.L. GORE & ASSOCIATES

Patients

Seq Age Sex Outcome Treatment
1 70 YR Other