UNKNOWN IMPLANTABLE NEUROSTIMULATOR
Report
- Report Number
- 3007566237-2017-04024
- Event Type
- Injury
- Date Received
- September 23, 2017
- Date of Event
- July 5, 2017
- Report Date
- September 22, 2017
- Manufacturer
- MEDTRONIC NEUROMODULATION
- Product Code
- MHY
- PMA / PMN Number
- P960009
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GM
- Reporter Occupation
- PHYSICIAN
Narratives
THIS VALUE IS THE AVERAGE AGE OF THE PATIENTS REPORTED IN THE ARTICLE AS SPECIFIC PATIENTS COULD NOT BE IDENTIFIED. THIS VALUE REFLECTS THE GENDER OF THE MAJORITY OF THE PATIENTS REPORTED IN THE ARTICLE AS SPECIFIC PATIENTS COULD NOT BE IDENTIFIED. PLEASE NOTE THAT THE ACTUAL DATE OF DEATH WAS NOT PROVIDED IN THE LITERATURE ARTICLE; THIS DATE IS BASED ON THE DATE OF ARTICLE PUBLICATION. PLEASE NOTE THAT THIS DATE IS BASED OFF OF THE DATE OF PUBLICATION OF THE ARTICLE AS THE EVENT DATES WERE NOT PROVIDED IN THE PUBLISHED LITERATURE. INFORMATION REFERENCES THE MAIN COMPONENT OF ONE OF THE SYSTEMS INVOLVED IN THE REPORTED EVENTS; OTHER APPLICABLE COMPONENTS ARE: PRODUCT ID: NEU_INS_STIMULATOR, LOT# UNKNOWN, PRODUCT TYPE: IMPLANTABLE NEUROSTIMULATOR. BUHMANN, C., HUCKHAGEL, T., ENGEL, K., GULBERTI, A., HIDDING, U., POETTER-NERGER, M., GOERENDT, I., LUDEWIG, P., BRAASS, H., CHOE, C., KRAJEWSKI, K., OEHLWEIN, C., MITTMANN, K., ENGEL, AK., GERLOFF, C., WESTPHAL, M., KÖPPEN, JA., MOLL, CKE., HAMEL, W. ADVERSE EVENTS IN DEEP BRAIN STIMULATION: A RETROSPECTIVE LONG-TERM ANALYSIS OF NEUROLOGICAL, PSYCHIATRIC AND OTHER OCCURRENCES. PLOS ONE. 2017;12(7):(B)(4). DPI: (B)(4). A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED. (B)(4).
IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
THE EXTENT TO WHICH DEEP BRAIN STIMULATION (DBS) CAN IMPROVE QUALITY OF LIFE MAY BE PERCEIVED AS A PERMANENT TRADE-OFF BETWEEN NEUROLOGICAL IMPROVEMENTS AND COMPLICATIONS OF THERAPY, COMORBIDITIES, AND DISEASE PROGRESSION. PATIENTS AND METHODS WE RETROSPECTIVELY INVESTIGATED 123 CONSECUTIVE AND NON-PRESELECTED PATIENTS. INDICATIONS FOR DBS SURGERY WERE PARKINSON'S DISEASE (82), DYSTONIA (18), TREMOR OF DIFFERENT ETIOLOGY (21), HUNTINGTON'S DISEASE (1) AND GILLES DE LA TOURETTE SYNDROME (1). AES WERE DEFINED AS ANY UNTOWARD CLINICAL OCCURRENCE, SIGN OR PATIENT COMPLAINT OR UNINTENDED DISEASE IF RELATED OR UNRELATED TO THE SURGICAL PROCEDURES, IMPLANTED DEVICES OR ONGOING DBS THERAPY. RESULTS OVER A MEAN/MEDIAN FOLLOW-UP PERIOD OF 4.7 YEARS (578 PATIENT-YEARS) 433 AES WERE RECORDED IN 106 OF 123 PATIENTS (86.2%). THERE WAS NO MORTALITY OR PERSISTENT MORBIDITY FROM THE SURGICAL PROCEDURE. ALL SERIOUS ADVERSE EVENTS (SAES) THAT OCCURRED WITHIN 4 WEEKS OF SURGERY WERE REVERSIBLE. NEUROLOGICAL AES (193 IN 85 PATIENTS) AND PSYCHIATRIC AES (78 IN 48 PATIENTS) WERE DOCUMENTED MOST FREQUENTLY. AES IN 4 PATIENTS (SUICIDE UNDER GPI STIMULATION, WEIGHT GAIN >20 KG, IMPAIRMENT OF GAIT AND SPEECH, COGNITIVE DECLINE >2 YEARS FOLLOWING SURGERY) WERE SEVERE OR WORSE, AT LEAST POSSIBLY RELATED TO DBS AND NON REVERSIBLE. IN PD 23.1% OF THE STN-STIMULATED PATIENTS EXPERIENCED NON-REVERSIBLE (OR UNKNOWN REVERSIBILITY) AES THAT WERE AT LEAST POSSIBLY RELATED TO DBS IN THE FORM OF IMPAIRED SPEECH OR GAIT, DEPRESSION, WEIGHT GAIN, COGNITIVE DISTURBANCES OR URINARY INCONTINENCE (SEVERITY WAS MILD OR MODERATE IN 15 OF 18 PATIENTS). AGE AND HOEHN & YAHR STAGE OF STN-SIMULATED PD PATIENTS, BUT NOT PREOPERATIVE MOTOR IMPAIRMENT OR RESPONSE TO LEVODOPA, SHOWED A WEAK CORRELATION (R = 0.24 AND 0.22, RESPECTIVELY) WITH THE NUMBER OF AES. CONCLUSIONS DBS-RELATED AES THAT WERE SEVERE OR WORSE AND NON-REVERSIBLE WERE ONLY OBSERVED IN PD (4 OF 82 PATIENTS; 4.9%), BUT NOT IN OTHER DISEASES. PD PATIENTS EXHIBITED A SIGNIFICANT RISK FOR NON-SEVERE AES MOST OF WHICH ALSO REPRESENTED PREEXISTING AND PROGRESSIVE AXIAL AND NONMOTOR SYMPTOMS OF PD. MILD GAIT AND/OR SPEECH DISTURBANCES WERE RATHER FREQUENT COMPLAINTS UNDER VIM STIMULATION. GPI STIMULATION FOR DYSTONIA COULD BE APPLIED WITH NEGLIGIBLE DBS-RELATED SIDE EFFECTS. REPORTED EVENTS: 1. A PATIENT WITH DBS FOR PD EXPERIENCED LIFE-THREATENING AKINESIA LESS THAN A MONTH AFTER IMPLANT THAT WAS ASSESSED AS DEFINITELY RELATED TO THE DEVICE/THERAPY. THE AUTHORS STATED THAT ALL SEVERE ADVERSE EVENTS THAT OCCURRED WITHIN THE FIRST MONTH OF SURGERY WERE REVERSIBLE. 2. A PATIENT WITH DBS FOR PD EXPERIENCED SEVERE AKINESIA LESS THAN A MONTH AFTER IMPLANT THAT WAS ASSESSED AS DEFINITELY RELATED TO THE DEVICE/THERAPY. THE AUTHORS STATED THAT ALL SEVERE ADVERSE EVENTS THAT OCCURRED WITHIN THE FIRST MONTH OF SURGERY WERE REVERSIBLE. 3. A PATIENT WITH DBS FOR PD EXPERIENCED REVERSIBLE HALLUCINATION. 4. A PATIENT WITH DBS FOR PD EXPERIENCED REVERSIBLE PARESIS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 668852 | UNKNOWN IMPLANTABLE NEUROSTIMULATOR | STIMULATOR, ELECTRICAL, IMPLANTED, FOR PARKINSONIAN TREMOR | MHY | MEDTRONIC NEUROMODULATION | NEU_INS_STIMULATOR | UNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 59 YR | Life Threatening| O| R |