FDA Adverse Event Death Summary report: N

THERASPHERE®

MDR report key: 6871919 · Received September 18, 2017

Report

Report Number
3002124543-2017-00040
Event Type
Death
Date Received
September 18, 2017
Date of Event
February 1, 2017
Report Date
August 24, 2017
Manufacturer
BIOCOMPATIBLES UK LTD.
Product Code
NAW
UDI-DI
05060116920284
PMA / PMN Number
H980006
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
UK
Reporter Occupation
PHYSICIAN

Narratives

Description of Event or Problem · 1

(B)(4). (B)(6). LAST SIGNIFICANT SAE REPORT: (B)(6) 2017. SAE: RADIOEMBOLIZATION INDUCED LIVER DISEASE (REILD) (RADIATION HEPATITIS). THIS REPORT CONCERNS SUBJECT (B)(6), A FEMALE (B)(6), WHO WAS ENROLLED IN STUDY (B)(6) ENTITLED "A PHASE III CLINICAL TRIAL EVALUATING THERASPHERE® IN SUBJECTS WITH METASTATIC COLORECTAL CARCINOMA OF THE LIVER WHO HAVE FAILED FIRST LINE CHEMOTHERAPY". THE SUBJECT RECEIVED THERASPHERE® 125.9 GY TO THE LEFT LOBE AND 131.7 GY TO THE RIGHT LOBE ON (B)(6) 2016. THE SUBJECT STARTED TREATMENT WITH SECOND-LINE CHEMOTHERAPY FOR METASTATIC COLORECTAL CARCINOMA ON (B)(6) 2016; FOLFIRI REGIMEN (IRINOTECAN 240 MG IV, FOLINIC ACID 350 MG IV AND FLUOROURACIL 4450 MG IV). THE SUBJECT TOOK THE FOURTH CYCLE OF SECOND-LINE CHEMOTHERAPY ON (B)(6) 2016. THE SUBJECT HAD NO RELEVANT MEDICAL HISTORY AND CONCOMITANT MEDICATION WERE NOT REPORTED AT THE TIME OF THIS REPORT. ON (B)(6) 2016, (B)(6) 2017, THE SUBJECT'S ALT RESULT WAS 15 IU/L (NORMAL 5 - 45), 18 IU/L (NORMAL 5 - 45), 27 IU/L (NORMAL 5 - 45), 33 IU/L (NORMAL 5 - 45), 44 IU/L (NORMAL 5 - 45) AND 59 IU/L (NORMAL 10 - 49) RESPECTIVELY. ON (B)(6) 2017, HER CT THORAX AND ABDOMEN REVEALED PARTIAL DISEASE RESPONSE, CHANGES TO THE LIVER PARENCHYMA WITH ELEVATED ALT AND MODERATE VALUE ASCITES IS CONSISTENT WITH RADIOEMBOLIZATION INDUCED LIVER DISEASE (REILD). ON (B)(6) 2017, THE SUBJECT WAS HOSPITALIZED FOR RADIOEMBOLIZATION INDUCED LIVER DISEASE. TREATMENT WITH DEXAMETHASONE WAS STARTED. ON (B)(6) 2017, HER BLOOD TEST REVEALED UREA 10.0 MMOL/L (NORMAL 2.5 - 7.8), TOTAL PROTEIN 57 G/L (NORMAL 60 - 80), ALBUMIN 26 G/L (NORMAL 35 - 50), TOTAL BILIRUBIN 80 UMOL/L (NORMAL 0 - 21), ALKALINE PHOSPHATASE 484 IU/L (NORMAL 30 - 130), AST 220 IU/L (NORMAL 0 - 34), LDH 572 IU/L (NORMAL 200 - 550), GGT 527 IU/L (NORMAL LESS THAN 38). ON (B)(6) 2017, THE SUBJECT'S BLOOD TEST REVEALED UREA 10.2 MMOL/L (NORMAL 2.5 - 7.8), TOTAL PROTEIN 53 G/L (NORMAL 60 - 80), ALBUMIN 23 G/L (NORMAL 35 - 50), TOTAL BILIRUBIN 142 UMOL/L (NORMAL 0 - 21), ALKALINE PHOSPHATASE 476 IU/L (NORMAL 30 - 130), AST 194 IU/L (NORMAL 0 - 34), LDH 624 IU/L (NORMAL 200 - 550), GGT 558 IU/L (NORMAL LESS THAN 38). ON (B)(6) 2017, HER BLOOD TEST REVEALED UREA 11.6 MMOL/L (NORMAL 2.5 - 7.8), TOTAL PROTEIN 62 G/L (NORMAL 60 - 80), ALBUMIN 25 G/L (NORMAL 35 - 50), TOTAL BILIRUBIN 168 UMOL/L (NORMAL 0 - 21), ALKALINE PHOSPHATASE 533 IU/L (NORMAL 30 - 130), AST 148 IU/L (NORMAL 0 - 34), LDH 650 IU/L (NORMAL 200 - 550), GGT 625 IU/L (NORMAL LESS THAN 38). ON (B)(6) 2017, ASCETIC DRAIN WAS INSERTED AND HER BLOOD TEST REVEALED UREA 9.8 MMOL/L (NORMAL 2.5 - 7.8), TOTAL PROTEIN 53 G/L (NORMAL 60 - 80), ALBUMIN 24 G/L (NORMAL 35 - 50), TOTAL BILIRUBIN 152 UMOL/L (NORMAL 0 - 21), ALKALINE PHOSPHATASE 406 IU/L (NORMAL 30 - 130), AST 82 IU/L (NORMAL 0 - 34), LDH 620 IU/L (NORMAL 200 - 550), GGT 421 IU/L (NORMAL LESS THAN 38). ON (B)(6) 2017, THE SUBJECT WAS DISCHARGED FROM THE HOSPITAL. IT WAS STATED THAT SHE SHOWED VERY POOR PROGNOSIS AND HER CONDITION DETERIORATED. ON (B)(6) 2017, THE SUBJECT DIED DUE TO RADIATION INDUCED LIVER FAILURE. THE SUBJECT DISCONTINUED PARTICIPATION IN THE STUDY DUE TO HER DEATH. THE SITE CONFIRMED THAT AUTOPSY WAS NOT PERFORMED. NO FURTHER UPDATES IS EXPECTED AND CASE IS CLOSED. THE INVESTIGATOR ASSESSED THE EVENT OF RADIOEMBOLIZATION INDUCED LIVER DISEASE AS GRADE-5 (FATAL) IN INTENSITY, SERIOUS DUE TO HOSPITALIZATION AND DEATH OF THE SUBJECT AND DEFINITELY RELATED TO STUDY DEVICE AND UNRELATED TO STUDY PROCEDURE. THE EVENT WAS UNRELATED TO SUBJECT'S SECOND LINE CHEMOTHERAPY. THE COMPANY AGREED WITH THE INVESTIGATOR'S CAUSALITY ASSESSMENT. A SUPPLEMENTAL REPORT WILL BE SUBMITTED IF ADDITIONAL RELEVANT INFORMATION IS RECEIVED.

Description of Event or Problem · 1

THIS FOLLOW-UP REPORT IS BEING SENT TO CORRECT PMA/510(K) NUMBER TO H980006.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
654713 THERASPHERE® THERASPHERE® NAW BIOCOMPATIBLES UK LTD. 1699313 05060116920284

Patients

Seq Age Sex Outcome Treatment
1 69 YR Death| H