FDA Adverse Event Injury Summary report: N

EDWARDS SAPIEN TRANSCATHETER HEART VALVE

MDR report key: 6726008 · Received July 19, 2017

Report

Report Number
2015691-2017-02112
Event Type
Injury
Date Received
July 19, 2017
Date of Event
January 1, 2016
Report Date
June 30, 2017
Manufacturer
EDWARDS LIFESCIENCES
Product Code
NPT
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
SW
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

REFERENCE RELATED MANUFACTURING REPORT NUMBERS: 2015691-2017-02113, 2015691-2017-02114, 2015691-2017-02111, 2015691-2017-02116. 2015691-2017-02118, AND 2015691-2017-02119

Additional Manufacturer Narrative · 1

PER THE INSTRUCTIONS FOR USE, CARDIOVASCULAR INJURIES, INCLUDING PERFORATION OR DISSECTION OF VESSELS, VENTRICLE, MYOCARDIUM OR VALVULAR STRUCTURES, ARE POTENTIAL ADVERSE EVENTS ASSOCIATED WITH STANDARD CARDIAC CATHETERIZATION, BALLOON VALVULOPLASTY AND THE TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVR) PROCEDURE. THERE ARE SEVERAL POTENTIAL ETIOLOGIES FOR VENTRICULAR PERFORATION DURING A TAVR PROCEDURE, INCLUDING PERFORATION BY THE GUIDEWIRE, THE DELIVERY SYSTEM, OR THE TRANSVENOUS PACER (TVP) LEAD. PHYSICIANS ARE EXTENSIVELY TRAINED BY EDWARDS BEFORE THEY ARE QUALIFIED TO USE THE SAPIEN TRANSCATHETER HEART VALVE (THV). TRAINING INCLUDES PROPER GUIDEWIRE POSITIONING, FIXATION OF THE TVP TO PREVENT VENTRICLE PERFORATION, AND CAREFUL MANIPULATION OF DEVICES. PER THE PROCEDURE DIDACTIC, PATIENTS WITH SMALL VENTRICLES ARE AT PARTICULARLY HIGH RISK FOR VENTRICULAR PERFORATION. IN THIS CASE, THE CAUSE OF THE CARDIAC TAMPONADE (ARTICLE PATIENT) CANNOT BE DETERMINED; HOWEVER, DEVICE MANIPULATION MAY HAVE CONTRIBUTED TO THE EVENT. THE IFU AND TRAINING MANUALS HAVE BEEN REVIEWED AND NO INADEQUACIES HAVE BEEN IDENTIFIED WITH REGARDS TO WARNINGS, CONTRAINDICATIONS, AND THE DIRECTIONS/CONDITIONS FOR THE SUCCESSFUL USE OF THE DEVICE. COMPLAINT HISTORIES FOR ALL REPORTED EVENTS ARE REVIEWED AGAINST TRENDING CONTROL LIMITS ON A MONTHLY BASIS, AND ANY EXCURSIONS ABOVE THE CONTROL LIMITS ARE ASSESSED AND DOCUMENTED AS PART OF THIS MONTHLY REVIEW. NO CORRECTIVE OR PREVENTATIVE ACTIONS ARE REQUIRED. THE TYPE OF THV VALVE IS UNKNOWN; HOWEVER, THESE ARE THE POSSIBLE 510K NUMBER FOR SAPIEN, SAPIEN XT AND SAPIEN 3: P100041, P130009, AND P140031. (B)(6).

Description of Event or Problem · 1

AS REPORTED IN THE (B)(6) REGISTRY 2016, TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) HAS BEEN PERFORMED IN SWEDEN SINCE 2008. IN 2016, CARDIAC TAMPONADE HAD OCCURRED IN 6 CASES.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
506536 EDWARDS SAPIEN TRANSCATHETER HEART VALVE AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIVERED NPT EDWARDS LIFESCIENCES SAPIEN VALVE UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention