GMK-SPHERE TIBIAL TRAY FIXED CEMENTED SIZE 3 LEFT
Report
- Report Number
- 3005180920-2017-00372
- Event Type
- Injury
- Date Received
- July 13, 2017
- Date of Event
- June 13, 2017
- Report Date
- July 13, 2017
- Manufacturer
- MEDACTA INTERNATIONAL SA
- Product Code
- JWH
- UDI-DI
- 07630030819889
- PMA / PMN Number
- K090988
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AS
- Reporter Occupation
- OTHER
Narratives
PATIENT DETAILS: HIGH BMI; BILATERAL SPHERE KNEES. ON 30 JUNE 2017 THE MEDICAL AFFAIRS PERFORMED A CLINICAL EVALUATION AND COMMENTED AS FOLLOWS: TIBIAL LOOSENING IN CEMENTED TKA AFTER 1 YEAR IN A HIGH-BMI FEMALE PATIENT. LOOSENING IS HARDLY DISCERNIBLE FROM THE IMAGES SUPPLIED. NO CAUSE, EXCEPT POSSIBLY THE HIGH BMI, CAN BE IDENTIFIED WITH THE INFORMATION AT HAND. THE PICTURES OF THE IMPLANTS SHOW NO CEMENT BEING ATTACHED TO THE EXPLANTED COMPONENTS; IN SOME CASES THIS MAY BE RELATED TO A CEMENTING TECHNIQUE PROBLEM OR CEMENT FAILURE, BUT IT'S NOT ALWAYS THE CASE. BATCH REVIEW PERFORMED ON 10 JULY 2017. LOT 147905: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 26 FEBRUARY 2015. EXPIRATION DATE: 2020-01-31. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN ALREADY SOLD WITHOUT ANY SIMILAR REPORTED EVENT. GMK-SPHERE PRIMARY EXTENSION STEM Ø11MM / L 30 MM, CODE 02.07.F11030, LOT. 142842 (K133630) LOT 142842: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 14 MAY 2014. EXPIRATION DATE: 2019-03-31. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN ALREADY SOLD WITHOUT ANY SIMILAR REPORTED EVENT. ON 13 JULY 2017 THE R&D PROJECT MANAGER PERFORMED A PRELIMINARY INVESTIGATION BASED ON THE AVAILABLE IMAGES AND COMMENTED AS FOLLOWS: TIBIAL LOOSENING IN CEMENTED TKA AFTER 1 YEAR IN A HIGH-BMI FEMALE PATIENT. BASED ON THE PICTURES, IT IS NOT POSSIBLE TO IDENTIFY THE ROOT CAUSE OF THE EVENT, WE CAN ONLY ASSUME THAT HIGH BMI MIGHT HAVE FAVORED THIS LOOSENING. THE PICTURES OF THE IMPLANTS SHOW NO CEMENT BEING ATTACHED TO THE EXPLANTED COMPONENTS; IN SOME CASES THIS MAY BE RELATED TO A CEMENTING TECHNIQUE PROBLEM OR CEMENT FAILURE, BUT IT'S NOT ALWAYS THE CASE.
THE PATIENT REPORTED PAIN AND HAS GONE TO SEE ANOTHER SURGEON. THE BONE SCAN WAS SHOWING ACTIVITY ON BOTH THE TIBIA AND FEMUR APPARENTLY. THE SURGEON PLANNED TO DO PATELLA OR POTENTIALLY REVISE BOTH COMPONENTS. AT REVISION, THE SURGEON FOUND THE FEMUR WAS WELL FIXED BUT FELT THE TIBIA WAS LOOSE. THIS SURGEON WAS NOT FAMILIAR WITH THE GMK-SPHERE PROTHESIS AND DECIDED TO REVISE ALL COMPONENTS. HE ENDED UP IMPLANTING A HINGE PROSTHESIS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 491443 | GMK-SPHERE TIBIAL TRAY FIXED CEMENTED SIZE 3 LEFT | TIBIAL TRAY FIXED CEMENTED | JWH | MEDACTA INTERNATIONAL SA | 147905 | 07630030819889 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |