FDA Adverse Event Injury Summary report: N

UNK

MDR report key: 6660591 · Received June 22, 2017

Report

Report Number
2954740-2017-00183
Event Type
Injury
Date Received
June 22, 2017
Date of Event
May 20, 2005
Report Date
May 28, 2017
Manufacturer
MEDOS INTERNATIONAL SARL
Product Code
HCG
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
FR
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

CONTINUED FROM D2B: KRD/HCG. ARTICLE ATTACHED TO THE MDR: VALLE, J.N., PIEROT, L., MONTALVERNE, F. ET AL. (2005). UNRUPTURED INTRACRANIAL ANEURYSMS TREATED BY THREE-DIMENSIONAL COIL EMBOLIZATION: EVALUATION OF THE POSTOPERATIVE ANEURYSM OCCLUSION VOLUME. NEURORADIOLOGY (2005) 47: 438¿445 DOI 10.1007/S00234-004-1320-1. DATE OF EVENT, PRODUCT CODE, AND LOT NUMBER COULD NOT BE OBTAINED FROM THE AUTHOR. UDI: UNKNOWN PART NUMBER, ATTEMPTS TO OBTAIN PRODUCT PART NUMBER WERE UNSUCCESSFUL, UDI UNAVAILABLE. CONCLUSION: THE DEVICES WERE NOT AVAILABLE FOR ANALYSIS. IN ADDITION, NO LOT NUMBERS COULD BE OBTAINED; THEREFORE, A DHR COULD NOT BE PERFORMED FOR THE DEVICES. THROMBOEMBOLISM AND NEUROLOGICAL DEFICITS ARE KNOWN POTENTIAL ADVERSE EVENT ASSOCIATED WITH THE USE OF THE COILS AS OUTLINED IN THE INSTRUCTIONS FOR USE. PHARMACOLOGICAL AND CLINICAL FACTORS INCLUDING THIS PATIENT¿S PRE-PROCEDURE PRESENTATION WITH AN ANEURYSM MAY HAVE CONTRIBUTED TO THE EVENT. COIL PROTRUSION IN THE PARENT VESSEL AND VESSEL OCCLUSION ARE ALSO KNOWN COMPLICATIONS OF COIL EMBOLIZATION AND CAN BE ASSOCIATED TO ANEURYSM CHARACTERISTICS INCLUDING NECK WIDTH. COIL NON-DETACHMENT IS A KNOWN PROCEDURAL COMPLICATION, AND CAN BE RELATED TO PROCEDURAL/DEVICE HANDLING FACTORS. SINCE THERE WAS NO EVIDENCE TO SUGGEST THE EVENTS WERE RELATED TO A MANUFACTURING ISSUE, NO CORRECTIVE ACTIONS WILL BE TAKEN AT THIS TIME. THIS IS AN INITIAL/FINAL MDR REPORT. THIS IS 1 OF 6 MDRS BEING SUBMITTED FOR THIS COMPLAINT, WITH ASSOCIATED REPORT NUMBERS OF 2954740-2017-00185, 2954740-2017-00184, 2954740-2017-00183, 2954740-2017-00182, 2954740-2017-00186 AND 2954740-2017-00181.

Description of Event or Problem · 1

IN THE LITERATURE ARTICLE ¿UNRUPTURED INTRACRANIAL ANEURYSMS TREATED BY THREE-DIMENSIONAL COIL EMBOLIZATION: EVALUATION OF THE POSTOPERATIVE ANEURYSM OCCLUSION VOLUME¿ BY JEAN-NOE¨ L VALLE´E, LAURENT PIEROT, FRANCISCO MONT¿ALVERNE, ET AL, PUBLISHED NEURORADIOLOGY (2005) 47: 438¿445 DOI 10.1007/S00234-004-1320-1, THE AUTHORS EVALUATE THE POSTOPERATIVE ANEURYSM OCCLUSION VOLUME AND CLINICAL RESULTS OF TREATING UNRUPTURED INTRACRANIAL ANEURYSMS USING THREE-DIMENSIONAL (3D) COILS (UNKNOWN CATALOG/LOTS OF MICRUSPHERE, HELIPAQ, OR ULTIPAQ). COMPLICATIONS INCLUDED THROMBOEMBOLISM IN THREE CASES (WITH ONE EXPERIENCING NEUROLOGICAL DEFICIT AND ONE EXPERIENCED INTERMITTENT THIRD NERVE PALSY), PARENT ARTERY OCCLUSION IN ONE CASE, AND COIL PROTRUSION IN ONE CASE. TECHNICAL PROBLEMS DUE TO THE COILS WERE OBSERVED IN THREE (0.7%) OF THE 413 COILS USED. THESE PROBLEMS INCLUDED NON-DETACHMENT OF COILS IN TWO (0.5%) CASES AND NON-DEPLOYMENT IN ONE (0.2%) CASE, WITH NO CLINICAL CONSEQUENCE. NO PATIENT, DEVICE OR PROCEDURE SPECIFIC INFORMATION WAS PROVIDED IN THE ARTICLE. FROM NOVEMBER 2000 TO FEBRUARY 2003, 62 PATIENTS (43 WOMEN AND 19 MEN) WITH 62 UNRUPTURED INTRACRANIAL ANEURYSMS WERE TREATED WITH MICRUS MICROCOILS IN FIVE INTERVENTIONAL NEURORADIOLOGY CENTERS. IN ALL, 413 COILS WERE USED (114 SPHERICAL AND 299 HELICAL). PATIENTS WERE 31 TO 79 YEAR OF AGE. FIVE PATIENTS HAD PRESENTED WITH SYMPTOMATIC INTRADURAL ANEURYSMS, 11 PATIENTS HAD ASYMPTOMATIC ANEURYSMS ¿10 MM IN DIAMETER, EIGHT PATIENTS HAD EXPERIENCED A PREVIOUS SUBARACHNOID HAEMORRHAGE (SAH) FROM OTHER ANEURYSMS, AND SEVEN PATIENTS HAD A POSITIVE FAMILY HISTORY FOR ANEURYSMS OR ANEURYSMAL SAH. FIFTY-SIX (90%) ANEURYSMS WERE LOCATED IN THE ANTERIOR CIRCULATION, AND SIX (10%) IN THE POSTERIOR CIRCULATION ALL THE ANEURYSMS WERE FIRST FRAMED WITH ONE OR MORE SUCCESSIVE MICRUSPHERE COILS OF DECREASING SIZE AND THEN FILLED WITH HELICAL COILS (HELIPAQ, AND EXTRA-SOFT STRETCH-RESISTANT ULTIPAQ). ANATOMICAL AND CLINICAL RESULTS WERE EVALUATED BY UNIVARIATE ANALYSIS. FOR NECK SIZES </= 4 AND >4 MM, ANGIOGRAPHIC OCCLUSION WAS COMPLETE IN 31 (79%) AND 16 (70%) ANEURYSMS, RESPECTIVELY; THE MEAN PERCENTAGE OF OCCLUSION VOLUME WAS 31.4% AND 29.5%, RESPECTIVELY, AND POSTOPERATIVE MORBIDITY WAS 3% AND 4%, RESPECTIVELY, WITH NO SIGNIFICANT DIFFERENCES BETWEEN THE TWO GROUPS. THERE WERE NO DEATHS. TECHNICAL COMPLICATIONS WERE OBSERVED IN FIVE (8%) OF THE 62 PROCEDURES PERFORMED TO TREAT 62 ANEURYSMS. THESE COMPLICATIONS WERE DUE TO THE PROCEDURE IN THREE (8%) OF THE 39 PROCEDURES AND TWO (9%) OF THE 23 PROCEDURES FOR TREATING ANEURYSMS WITH A NECK </= 4 AND >4 MM, RESPECTIVELY. ONE (2%) PATIENT HAD NEUROLOGICAL DEFICIT DUE TO THROMBOEMBOLISM; HIS NATIONAL INSTITUTES OF HEALTH STROKE SCALE (NIHSS) SCORE WAS 7, AND ONE (2%) PATIENT HAD INTERMITTENT THIRD NERVE PALSY FOR 48H. THERE WERE NO DEATHS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
441155 UNK NEUROVASCULAR EMBOLIZATION DEVICE HCG MEDOS INTERNATIONAL SARL NA UNK

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention