FDA Adverse Event Injury Summary report: N

APPLIANCE,FIXATION,NAIL

MDR report key: 6647558 · Received June 16, 2017

Report

Report Number
2520274-2017-11809
Event Type
Injury
Date Received
June 16, 2017
Report Date
June 1, 2017
Manufacturer
SYNTHES (USA)
Product Code
KTT
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
PA, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. CHO, H.M., ET AL. (2016). CLINICAL AND FUNCTIONAL OUTCOMES OF TREATMENT FOR TYPE A1 INTERTROCHANTERIC FEMORAL FRACTURE IN ELDERLY PATIENTS: COMPARISON OF DYNAMIC HIP SCREW AND PROXIMAL FEMORAL NAIL ANTIROTATION, HIP PELVIS 28(4): 232-242. THIS REPORT IS FOR AN UNKNOWN DHS SYSTEM = DYNAMIC COMPRESSION PLATE (DCP), CORTEX SCREWS, AND LAG SCREW, UNKNOWN QUANTITY # / UNKNOWN LOT #. (OTHER NUMBER) UDI # UNKNOWN PART NUMBER, UDI IS UNAVAILABLE. THE INVESTIGATION COULD NOT BE COMPLETED; NO CONCLUSION COULD BE DRAWN, AS NO PRODUCT WAS RETURNED AND NO LOT NUMBER OR PART NUMBER WAS PROVIDED. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

THIS REPORT IS BEING FILED AFTER THE SUBSEQUENT REVIEW OF THE FOLLOWING LITERATURE ARTICLE: CHO, H.M., ET AL. (2016). CLINICAL AND FUNCTIONAL OUTCOMES OF TREATMENT FOR TYPE A1 INTERTROCHANTERIC FEMORAL FRACTURE IN ELDERLY PATIENTS: COMPARISON OF DYNAMIC HIP SCREW AND PROXIMAL FEMORAL NAIL ANTIROTATION, HIP PELVIS 28(4): 232-242, 2016. KOREA. THE STUDY OBJECTIVE WAS TO EVALUATE AND COMPARE THE CLINICAL AND FUNCTIONAL OUTCOMES OF DYNAMIC HIP SCREW (DHS) AND PROXIMAL FEMORAL NAIL ANTIROTATION (PFNA) TREATMENT OF AO TYPE 1 INTERTROCHANTERIC FRACTURES IN ELDERLY PATIENTS. THE STUDY INCLUDED PATIENTS WITH INTERTROCHANTERIC FEMORAL FRACTURE BETWEEN JANUARY 2004 AND DECEMBER 2014, THOSE YOUNGER THAN 70 YEARS, WITH AO FRACTURE CLASSIFICATION OF TYPE 2 OR HIGHER 7), WITH BILATERAL FRACTURE. 113 CASES TREATED WITH DHS (DHS GROUP), AND 81 CASES TREATED WITH PFNA (PFNA GROUP). REGARDING THE DHS AND PFNA GROUPS, RESPECTIVELY: MEAN PATIENT AGE, 84.2 (70- 93) YEARS AND 81.0 (70-94) YEARS. DHS GROUP RECEIVED A 135 DEGREE-ANGLED PLATE AND HIP SCREWS. THE REDUCTION METHOD USED FOR THE PFNA GROUP WAS SIMILAR TO THAT USED FOR DHS GROUP. AFTER REAMING THE LATERAL CORTEX, A HELICAL BLADE WAS INSERTED, FOLLOWED BY THE INSERTION OF DISTAL LOCKING SCREWS. THE SIZE OF THE NAIL WAS DETERMINED BASED ON THE PREOPERATIVE RADIOGRAPHS, AND, FOR ALL PATIENTS, THE NECK-SHAFT ANGLE WAS 130 DEGREES, WITH A LENGTH OF 170 MM OR 200 MM. THE FOLLOWING COMPLICATIONS WERE REPORTED: IN THE DHS GROUP: ONE PATIENT HAD A SWITCHING (REVISION) TO ARTIFICIAL HIP REPLACEMENT DUE TO HIP SCREW CUT OUT. TWO PATIENTS HAD SWITCHING (REVISION) TO ARTIFICIAL HIP REPLACEMENT DUE TO NON-UNION AND UNKNOWN METAL FAILURE. FIXATION FAILURE WAS DEFINED AS VARUS DEFORMITY WITH A CHANGE OF 10 DEGREES IN THE ANGLE BETWEEN THE SHAFT AND THE HEAD OF THE FEMUR; FEMORAL HEAD CUT-OUT CAUSED BY THE LAG SCREW; OR EXCESSIVE SLIDING (15 MM). THIS IS REPORT 4 OF 8 FOR (B)(4). THIS REPORT IS FOR AN UNKNOWN QUANTITY OF DHS SYSTEM = DYNAMIC COMPRESSION PLATE (DCP), CORTEX SCREWS, AND LAG SCREW, UNKNOWN PART # / LOT #.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
427455 APPLIANCE,FIXATION,NAIL KTT SYNTHES (USA)

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention