FDA Adverse Event Malfunction Summary report: N

NITINOL TC ELECTRODE

MDR report key: 6625521 · Received June 8, 2017

Report

Report Number
3006630150-2017-01952
Event Type
Malfunction
Date Received
June 8, 2017
Date of Event
May 17, 2017
Report Date
May 17, 2017
Manufacturer
COSMAN MEDICAL
Product Code
GXI
PMA / PMN Number
K050084
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

ADDITIONAL SUSPECT MEDICAL DEVICE COMPONENTS INVOLVED: MODEL #: TCN-10, LOT #: 101716, DESCRIPTION: NITINOL TC ELECTRODE, 100 MM QUANTITY: 5. MODEL #: TCN-10, LOT #: 122316, DESCRIPTION: NITINOL TC ELECTRODE, 100 MM QUANTITY: 3.

Additional Manufacturer Narrative · 1

ADDITIONAL SUSPECT MEDICAL DEVICE COMPONENTS INVOLVED: MODEL #: TCN-10-3M LOT #: 101716 DESCRIPTION: NITINOL TC ELECTRODE, 100 MM WITH 3M CABLE QUANTITY: 5 MODEL #: TCN-10-3M LOT #: 122316 DESCRIPTION: NITINOL TC ELECTRODE, 100 MM WITH 3M CABLE QUANTITY: 3 THERE WERE A TOTAL OF EIGHT ELECTRODES ANALYZED. DEVICE EVALUATION OF TCN-10 (LOT 122316 X QUANTITY 3) AND TCN-10-3M (LOT 101716 X QUANTITY 3) ELECTRODE EPOXY ARE DISCOLORED AND HAVE SMALL CHIP AWAY. TCN-10-3M (101716 X QUANTITY 1) ELECTRODE EPOXY IS DISCOLORED AND IT HAS DARK SPOTS NEAR THE SHAFT. TCN-10-3M (101716 X QUANTITY 1) ELECTRODE EPOXY IS DISCOLORED AND IT HAS A YELLOW PATCH NEAR THE SHAFT. IF THE EPOXY IS SUBJECTED TO TOO MANY AUTOCLAVE CYCLES, THE EPOXY BECOMES BRITTLE AND DISCOLORED.

Description of Event or Problem · 1

A REPORT WAS RECEIVED THAT A MEDICAL FACILITY HAS MULTIPLE ELECTRODES THAT ARE SEEPING BLOOD OUT OF THE HUB. THE FACILITY CLEANS THE ELECTRODES BY SOAKING THEM IN ENZYMATIC FLUID AND USING A SOFT BRISTLE BRUSH TO REMOVE ANY TISSUE OR BLOOD FROM THE HUB PRIOR TO STERILIZATION. THE ELECTRODES WERE STERILIZED IN A PEEL PACK USING AN AUTOCLAVE AT 272 DEGREES FOR 4 MINUTES AND DRIED FOR 30 MINUTES. THE FACILITY PERFORMS AN AVERAGE OF 5 PROCEDURES A WEEK.

Description of Event or Problem · 1

A REPORT WAS RECEIVED THAT A MEDICAL FACILITY HAS MULTIPLE ELECTRODES THAT ARE SEEPING BLOOD OUT OF THE HUB. THE FACILITY CLEANS THE ELECTRODES BY SOAKING THEM IN ENZYMATIC FLUID AND USING A SOFT BRISTLE BRUSH TO REMOVE ANY TISSUE OR BLOOD FROM THE HUB PRIOR TO STERILIZATION. THE ELECTRODES WERE STERILIZED IN A PEEL PACK USING AN AUTOCLAVE AT 272 DEGREES FOR 4 MINUTES AND DRIED FOR 30 MINUTES. THE FACILITY PERFORMS AN AVERAGE OF 5 PROCEDURES A WEEK.