FDA Adverse Event Malfunction Summary report: N

PHASIX MESH

MDR report key: 6619797 · Received June 7, 2017

Report

Report Number
1213643-2017-00339
Event Type
Malfunction
Date Received
June 7, 2017
Date of Event
April 5, 2017
Report Date
June 7, 2017
Manufacturer
DAVOL INC., SUB. C.R. BARD, INC.
Product Code
OOD
PMA / PMN Number
K142818
Removal / Correction Number
NA
Product Problem
Yes
Report Source
Manufacturer report
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

THERE WAS NO CONTACT INFORMATION PROVIDED ON THE MAUDE EVENT REPORT. DAVOL FIELD ASSURANCE MADE A REQUEST TO THE FDA FOR THE CONTACT INFORMATION HOWEVER CONTACT RESPONDED THAT THEY ARE NOT ABLE TO PROVIDE THAT INFORMATION TO DAVOL. THEREFORE WE ARE UNABLE TO FOLLOW UP DIRECTLY TO REQUEST ADDITIONAL INFORMATION INCLUDING THE LOT NUMBER OF THE IMPLANTED PHASIX DEVICE. THERE WAS NO REPORT OF A PATIENT INJURY OR THAT MEDICAL INTERVENTION WAS PERFORMED. IT WAS ALLEGED IN THE REPORT THAT THE CUSTOMER REQUESTED AND RECEIVED A SHELF LIFE EXTENSION LETTER FROM BARD FOR PHASIX ST CATALOG NO. 1200710 / LOT NO HUAN2028. NOTE: PHASIX ST WAS INITIALLY RELEASED WITH A 12-MONTH SHELF LIFE. LATER ADDITIONAL TEST DATA SUPPORTED A 24-MONTH SHELF LIFE WHICH IS CURRENTLY THE ESTABLISHED EXPIRATION PERIOD FOR PHASIX ST. IT WAS REPORTED THAT A MEMBER OF THE HOSPITAL STAFF INADVERTENTLY ASSUMED THAT 12-MONTH EXTENSION WOULD ALSO BE APPLICABLE TO STANDARD PHASIX MESH IN THEIR INVENTORY THAT HAS A 24-MONTH SHELF LIFE. THIS USER ERROR RESULTED IN THE IMPLANTATION OF AN EXPIRED DEVICE. THE INFORMATION PROVIDED BY BARD REPRESENTS ALL OF THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BARD. REMAINS IMPLANTED.

Description of Event or Problem · 1

THE FOLLOWING WAS REPORTED VIA MAUDE EVENT REPORT (MW 5069385) "LABEL ON PACKAGE OF PHASIX ST MESH PKG HAS EXPIRATION DATE OF 02/28/2017. LETTER FROM BARD ATTACHED TO PACKAGE STATES PRODUCT EXPIRATION EXTENDED 24 MONTHS. STAFF INSTRUCTED TO GO BY LETTER. THE REGULAR PHASIX MESH PACKAGE LOOKS SIMILAR TO THE PHASIX ST PKG. EXPIRED PHASIX MESH PLACED IN PT WHEN RN THOUGHT ALL PHASIX MESH HAD 24 MO (MONTH) EXTENSION."

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
399274 PHASIX MESH SURGICAL MESH OOD DAVOL INC., SUB. C.R. BARD, INC. NI

Patients

Seq Age Sex Outcome Treatment
1