FDA Adverse Event Injury Summary report: N

NGENUITY DIGITAL VISUALIZATION SYSTEM

MDR report key: 6614264 · Received June 6, 2017

Report

Report Number
2028159-2017-02377
Event Type
Injury
Date Received
June 6, 2017
Report Date
June 29, 2017
Manufacturer
ALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER
Product Code
EPT
PMA / PMN Number
EXEMPT
Removal / Correction Number
NA
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
MA, US
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

INVESTIGATION INCLUDING ROOT CAUSE ANALYSIS IS IN PROGRESS. A SUPPLEMENTAL MDR WILL BE FILED AS NECESSARY IN ACCORDANCE WITH 21 CFR 803.56 WHEN ADDITIONAL REPORTABLE INFORMATION BECOMES AVAILABLE. THE MANUFACTURER INTERNAL REFERENCE NUMBER IS: (B)(4).

Additional Manufacturer Narrative · 1

A COMPANY CLINICAL ANALYST REVIEWED THIS CASE AND STATED THE FOLLOWING: ¿THE CUSTOMER REPORTED ¿DIMINISHED VISION.¿ ADDITIONAL INFORMATION RECEIVED FROM THE SURGEON INDICATED IT WAS TOO EARLY TO TELL IF THE EVENT IS ACTUALLY A COMPLICATION FROM SURGERY. NO FURTHER INFORMATION HAS BEEN RECEIVED. INDOCYANINE GREEN (ICG) SELECTIVELY STAINS THE INTERNAL LIMITING MEMBRANE (ILM) OF THE RETINA, AND HELPS TO VISUALIZE AND REMOVE THE MEMBRANE FROM THE RETINA. TOXICITY AND DAMAGE TO THE RETINA HAS BEEN REPORTED IN STUDIES FOLLOWING MACULAR SURGERY. TOXIC EFFECTS CAN OCCUR TO RETINAL GLIAL CELLS, TO THE NERVE FIBER LAYER, TO RETINAL GANGLION CELLS, AND TO THE OPTIC NERVE. IN CASE OF SUBRETINAL APPLICATION, THE RETINAL PIGMENT EPITHELIUM CAN BE AFFECTED. THE MECHANISMS OF TOXICITY ARE UNCLEAR. WHETHER THE DYE ITSELF OR SOME PREPARATIONS ONLY ARE CAUSING HARM TO THE RETINA IS SUBJECT OF AN ONGOING DEBATE. ICG CHANGES THE LIGHT ABSORPTION PROPERTIES OF THE ILM AND ENHANCES THE STIFFNESS OF THE MEMBRANE, PROBABLY BY CROSSLINKING OF COLLAGEN FIBERS. THIS EFFECT IS RESPONSIBLE FOR THE EASE OF MEMBRANE REMOVAL COMPARED TO UNAIDED ILM PEELING WITH BETTER VISUALIZATION. WHETHER A PHOTOTOXIC EFFECT PLAYS A CLINICALLY SIGNIFICANT ROLE IN MACULAR SURGERY HAS NEITHER BEEN PROVEN NOR RULED OUT YET. ICG AT CONCENTRATIONS HIGHER THAN 1.25% OR APPLICATION OF THE DYE IN AIR ARE VERY LIKELY CAUSING RETINAL DAMAGE. IN ADDITION, LOWER CONCENTRATIONS ALSO CARRY THE RISK OF IATROGENIC DAMAGE, DEPENDING ON THE FINAL CONCENTRATION OF POTENTIALLY TOXIC SUBSTANCES AT THE VITREOMACULAR INTERFACE AND ON OTHER MECHANISMS. MODIFICATIONS IN TECHNIQUE HAVE PRIMARILY FOCUSED ON EFFORTS TO REDUCE THE POTENTIAL TOXICITY OF ICG. THESE MODIFICATIONS HAVE INCLUDED VARIATIONS IN THE ICG CONCENTRATION, LIMITING THE STAINING TIME, AND REDUCTION OF LIGHT INTENSITY AND EXPOSURE TIME. PROTECTING THE HOLE WITH A VISCOELASTIC SUBSTANCE TO KEEP THE BARE RETINAL PIGMENT EPITHELIUM FROM BEING EXPOSED TO THE ICG SOLUTION ALSO HAS BEEN REPORTED. THE EXACT MECHANISM FOR THE POTENTIAL TOXICITY IS NOT KNOWN. POSSIBLE MECHANISMS INCLUDE A DIRECT TOXIC EFFECT OF ICG TO THE RETINAL PIGMENT EPITHELIUM (RPE) CELLS AND/OR RETINA. IN VITRO STUDIES HAVE SHOWN THAT EXPOSURE OF ICG TO CULTURED HUMAN RPE CELLS RESULTS IN DOSE AND TIME DEPENDENT DAMAGE TO CELLULAR STRUCTURE. ALSO, IT HAS BEEN SHOWN THAT ICG EXPOSURE RESULTS IN ALTERATIONS IN CELLULAR FUNCTION IN HUMAN RPE CELL CULTURES. ANOTHER POTENTIAL MECHANISM IS ENHANCED PHOTOTOXICITY. ALTHOUGH THE USE OF ICG IMPROVES VISUALIZATION OF THE ILM AND SHOULD REDUCE SURGICAL TIME AND TIME OF LIGHT EXPOSURE, ICG MAY REDUCE THE "SAFE TIME" FOR LIGHT EXPOSURE, AND THEREFORE INCREASE THE POTENTIAL FOR LIGHT TOXICITY. ¿ NO FURTHER INFORMATION WAS ABLE TO BE OBTAINED FROM THIS CUSTOMER. WITH NO ADDITIONAL, RELATED INFORMATION PROVIDED, THE CUSTOMERS REPORTED EVENT WAS NOT ABLE TO BE CONFIRMED. (B)(4)

Description of Event or Problem · 1

A SURGEON REPORTED THAT A PATIENT HAD WORSENING VISION FOLLOWING ONE DAY POSTOPERATIVE RETINAL MEMBRANE PEEL. UPON FOLLOW UP, THE SURGEON INDICATED IT WAS TOO EARLY TO TELL IF THE EVENT IS ACTUALLY A COMPLICATION FROM SURGERY. ADDITIONAL INFORMATION HAS BEEN REQUESTED. THIS IS ONE OF TWO REPORTS FOR THIS FACILITY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
394648 NGENUITY DIGITAL VISUALIZATION SYSTEM MICROSCOPE, OPERATING & ACC AC-POWERED, OPHTHALMIC EPT ALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER NA NA

Patients

Seq Age Sex Outcome Treatment
1 Other