SCREW, FIXATION, BONE
Report
- Report Number
- 2520274-2017-11642
- Event Type
- Injury
- Date Received
- May 16, 2017
- Report Date
- April 19, 2017
- Manufacturer
- SYNTHES USA
- Product Code
- HWC
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- PA, US
- Reporter Occupation
- OTHER
Narratives
DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. JANG, J.H., AHN, J.M., LEE, H.J., AND MOON, N. H. (2017) SURGICAL OUTCOMES OF BIOLOGIC FIXATION FOR SUBTROCHANTERIC FRACTURE USING LOCKING COMPRESSION PLATES. HIP PELVIS 29(1): 68-76. THIS REPORT IS FOR UNKNOWN DISTAL LOCKING SCREW, UNKNOWN QUANTITY, UNKNOWN LOT. OTHER NUMBER: UDI: UNKNOWN PART NUMBER, UDI IS UNAVAILABLE. DEVICE NOT EVALUATED AS PRODUCT WAS NOT RETURNED. THE INVESTIGATION COULD NOT BE COMPLETED AND NO CONCLUSION COULD BE DRAWN, AS NO DEVICE WAS RETURNED AND NO LOT NUMBER OR PART NUMBER WAS PROVIDED. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
LITERATURE ARTICLES RECEIVED: THIS ARTICLE IS BEING FILED AFTER THE SUBSEQUENT REVIEW OF THE FOLLOWING LITERATURE ARTICLE, JANG, J.H., AHN, J.M., LEE, H.J., AND MOON, N. H. (2017) SURGICAL OUTCOMES OF BIOLOGIC FIXATION FOR SUBTROCHANTERIC FRACTURE USING LOCKING COMPRESSION PLATES. HIP PELVIS 29(1): 68-76. THIS STUDY AIMED TO EVALUATE THE SURGICAL OUTCOMES OF BIOLOGIC PLATING USING LOCKING COMPRESSION PLATE-DISTAL FEMUR (LCP-DF) IN PATIENTS WITH SUBTROCHANTERIC FRACTURE OF THE FEMUR BETWEEN JANUARY 2010 AND DECEMBER 2013, 28 CONSECUTIVE PATIENTS WITH SUBTROCHANTERIC FRACTURES OF THE FEMUR, TREATED WITH BIOLOGIC FIXATION USING LCP-DF, WERE ENROLLED. THE LESS INVASIVE STABILIZATION SYSTEM-DISTAL FEMUR (LISSDF; SYNTHES, WEST CHESTER, PA, USA) AND THE NEWLY DESIGNED LOCKING COMPRESSION PLATE-DISTAL FEMUR (LCP-DF, SYNTHES) WERE USED. THE PRESENT STUDY INCLUDED 19 MALES AND 9 FEMALES. THE MEAN AGE WAS 58.7 YEARS (RANGE, 24-85 YEARS). THE RIGHT FEMUR WAS INVOLVED IN 15 PATIENTS AND THE LEFT FEMUR WAS INVOLVED IN 13 PATIENTS. ONE PATIENT EXPERIENCED DISTAL LOCKING SCREW BREAKAGE DURING FOLLOW UP THIS IS REPORT 1 OF 4 FOR (B)(4). THIS REPORT IS FOR A UNKNOWN DISTAL LOCKING SCREW, SYNTHES .
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 351943 | SCREW, FIXATION, BONE | HWC | SYNTHES USA |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |