FDA Adverse Event Injury Summary report: N

ONYX

MDR report key: 6474551 · Received April 8, 2017

Report

Report Number
2029214-2017-00400
Event Type
Injury
Date Received
April 8, 2017
Date of Event
January 5, 2010
Report Date
March 13, 2017
Manufacturer
COVIDIEN (IRVINE)
Product Code
MFE
PMA / PMN Number
P030004
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
AS
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

THE EMBOLIC MATERIAL WAS NOT RETURNED AS IT WAS CONSUMED IN THE INTERVENTION. ATTEMPTS HAVE BEEN MADE TO OBTAIN ADDITIONAL INFORMATION. HOWEVER, OUR ATTEMPTS HAVE BEEN UNSUCCESSFUL. PER THE REPORTED INFORMATION, THE EVENT WAS CAUSED AT THE END OF PRIMING THE CATHETER. THE PATIENT RECEIVED MEDICATION WHICH WAS RESOLVED THE TCR WHICH DID NOT RECUR. THERE IS NO EVIDENCE OF A DEVICE MALFUNCTION OR DEFICIENCY BUT DOES APPEAR TO BE PROCEDURE RELATED, HOWEVER, ITS CAUSE CANNOT BE RELIABLY DETERMINED. MDR RELATED TO THIS EVENT: 2029214-2017-00399, 2029214-2017-00400, 2029214-2017-00401.

Additional Manufacturer Narrative · 1

IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 1

CITATION: THE TRIGEMINOCARDIAC REFLEX IN ONYX EMBOLISATION OF INTRACRANIAL DURAL ARTERIOVENOUS FISTULA. ONG CK1, ONG MT, LE K, POWER MA, WANG LL, LAM DV, PARKINSON RJ, WENDEROTH JD. J CLIN NEUROSCI. 2010 OCT;17(10):1267-70. TRIGEMINOCARDIAC REFLEX (TCR) WAS DEFINED AS ABRUPT BRADYCARDIA OF LESS THAN 60 BEATS/MINUTE AND HYPOTENSION WITH A DROP IN MEAN ARTERIAL BLOOD PRESSURE OF 20% OR MORE, DURING TRANSARTERIAL OR TRANSVENOUS INJECTION OF ONYX OR ITS SOLVENT, DIMETHYL-SULFOXIDE (DMSO). PATIENT 2 HAD A UNILATERAL CAVERNOUS SINUS DAVF, WITH AN OCCLUDED IPSILATERAL INFERIOR PETROSAL SINUS. GIVEN THIS, THE CAVERNOUS SINUS WAS ACCESSED VIA DIRECT PERCUTANEOUS TRANSORBITAL PUNCTURE THROUGH THE SUPERIOR ORBITAL FISSURE. TOWARDS THE END OF MICROCATHETER PRIMING WITH DMSO, THE PATIENT DEVELOPED SIGNIFICANT BRADYCARDIA WITH AN ABRUPT DROP OF ARTERIAL BLOOD PRESSURE. THE DMSO INJECTION WAS DECEASED IMMEDIATELY AND 1 MG OF ATROPINE GIVEN INTRAVENOUSLY. THE HAEMODYNAMIC PARAMETERS RETURNED TO NORMAL WITHIN 30¿40 SECONDS. THE EMBOLISATION WAS THEN RESUMED AND THE DAVF OBLITERATED, WITH NO FURTHER RECURRENCE OF THE TCR. THE POST-OPERATIVE RECOVERY WAS UNEVENTFUL FOR THE PATIENT. AT THE 3- AND 6-MONTH FOLLOW-UP, THE PATIENT WAS WELL AND SHOWED NO EVIDENCE OF ANY COMPLICATION THAT MIGHT HAVE BEEN RELATED TO THE INTRAOPERATIVE TCR.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
256385 ONYX AGENT, INJECTABLE, EMBOLIC MFE COVIDIEN (IRVINE)

Patients

Seq Age Sex Outcome Treatment
1 72 YR Required Intervention