ENDURANT
Report
- Report Number
- 2953200-2017-00384
- Event Type
- Injury
- Date Received
- March 13, 2017
- Date of Event
- June 6, 2016
- Report Date
- February 16, 2017
- Manufacturer
- MEDTRONIC IRELAND
- Product Code
- MIH
- PMA / PMN Number
- P100021
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- SW
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4).
CORRECTED INFORMATION: SEX. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
MEDTRONIC RECEIVED THE FOLLOWING INFORMATION OBTAINED FROM THE JOURNAL ARTICLE ENTITLED: RE-INTERVENTIONS AFTER ENDOVASCULAR AORTIC REPAIR FOR INFRARENAL ABDOMINAL ANEURYSMS: A RETROSPECTIVE COHORT STUDY. AUTHORS: HAKAN ROOS, HENRIK DJERF , LUDVIG BRISBY JEPPSSON, VICTORIA FROJD, TOMAS AXELSSON, ANDERS JEPPSSON, AND MARTEN FALKENBERG. ROOS ET AL. BMC CARDIOVASCULAR DISORDERS (2016) 16:124 DOI 10.1186/S12872-016-0309-0 AN ENDURANT AND TALENT STENT GRAFT SYSTEMS WERE IMPLANTED IN THE PATIENT FOR ENDOVASCULAR TREATMENT OF AN ABDOMINAL AORTIC ANEURYSM AND RUPTURED AORTIC ANEURYSMS. THE FOLLOWING INFORMATION IS IN THIS JOURNAL ARTICLE: TYPE I ENDOLEAK, TYPE II ENDOLEAK, TYPE III ENDOLEAK; TYPE IV ENDOLEAK, STENT GRAFT MIGRATION; SURGICAL CONVERSION; THROMBOSIS; FEVER; INFECTION; ISCHEMIA; INACCURATE DELIVERY; BLOOD LOSS; OCCLUSION; LOSS OF SEAL. ABSTRACT BACKGROUND: EARLY MORBIDITY AND MORTALITY ARE GENERALLY LOWER AFTER ENDOVASCULAR AORTIC REPAIR (EVAR), THAN AFTER OPEN REPAIR BUT RE-INTERVENTIONS AND LATE COMPLICATIONS ARE MORE COMMON. THE AIM OF THE PRESENT STUDY WAS TO MAKE A DETAILED DESCRIPTION OF RE-INTERVENTIONS AFTER EVAR-INCLUDING INCIDENCE, INDICATIONS, PROCEDURES, AND OUTCOME-WITH SPECIAL REFERENCE TO NON-ACCESS-RELATED RE-INTERVENTIONS. METHODS: THIS IS A RETROSPECTIVE SINGLE-CENTER COHORT STUDY OF RE-INTERVENTIONS AFTER STANDARD EVAR WITH SPECIAL REFERENCE TO NON-ACCESS-RELATED RE-INTERVENTIONS. CONSECUTIVE PATIENTS (N = 405) TREATED WITH STANDARD EVAR FOR NON-RUPTURED (N = 337) OR RUPTURED (N = 68) INFRARENAL ANEURYSMS BETWEEN 2005 AND 2013 WERE ANALYSED. MEDIAN FOLLOW-UP WAS 29 MONTHS (RANGE 0¿108). RESULTS: EIGHTY-NINE PATIENTS (22 %) UNDERWENT 113 RE-INTERVENTIONS DURING FOLLOW-UP. TWENTY-SEVEN PATIENTS (7 %) HAD 28 ACCESS RELATED RE-INTERVENTION, 65 PATIENTS (16 %) HAD 85 NON-ACCESS RELATED REINTERVENTIONS. NON-ACCESS RELATED RE-INTERVENTIONS WERE MORE COMMON IN RUPTURED ANEURYSMS THAN IN UNRUPTURED ANEURYSMS (22 VS. 15 %, P = 0.002). THE MOST FREQUENT INDICATIONS WERE ENDOLEAK TYPE I (N = 19), TYPE II (N = 21), OR TYPE III (N = 5); STENT GRAFT MIGRATION (N = 9); AND THROMBOSIS (N = 14). THE MOST FREQUENT PROCEDURES WERE EMBOLIZATION OF ENDOLEAK TYPE II (N = 21), ADDITIONAL ILIAC STENT GRAFT (N = 19), PROXIMAL EXTENSION (N = 12), THROMBOLYSIS (N = 8), ILIAC LIMB BARE-METAL STENTING (N = 6), AND STENT GRAFT RELINING (N = 7). ENDOVASCULAR TECHNIQUE WAS USED IN 83 % OF RE-INTERVENTIONS. THIRTY-DAY MORTALITY AFTER NON-ACCESS-RELATED RE-INTERVENTIONS WAS 15 % WHEN INITIATED FROM SYMPTOMS (RUPTURE OR INFECTION) AND 0 % WHEN INITIATED FROM FOLLOW-UP FINDINGS (P = 0.014). CUMULATIVE SURVIVAL FIVE YEARS AFTER EVAR WAS 72 % IN PATIENTS WITH A RE-INTERVENTION AND 59 % IN PATIENTS WITHOUT (P = 0.21). CONCLUSIONS: NON-ACCESS-RELATED RE-INTERVENTION RATES ARE STILL CONSIDERABLE AFTER EVAR AND MORE FREQUENT AFTER RUPTURED ANEURYSMS. ENDOLEAK EMBOLIZATION IS THE MOST FREQUENT PROCEDURE, FOLLOWED BY ADDITIONAL ILIAC STENT GRAFTS. OUTCOMES AFTER RE-INTERVENTIONS ARE GENERALLY GOOD, EXCEPT WHEN INITIATED BY RUPTURE OR INFECTION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 181281 | ENDURANT | SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT | MIH | MEDTRONIC IRELAND |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 75 YR | Required Intervention |