UNKNOWN AQUAMANTYS GENERATOR
Report
- Report Number
- 1226420-2017-00106
- Event Type
- Injury
- Date Received
- March 10, 2017
- Date of Event
- January 1, 2010
- Report Date
- February 10, 2017
- Manufacturer
- MEDTRONIC ADVANCED ENERGY, LLC
- Product Code
- GEI
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NH, US
- Reporter Occupation
- OTHER
Narratives
PRODUCT EVENT: 701706107 PATIENT INFORMATION INCOMPLETE AND MISSING PATIENT INFORMATION UNABLE TO BE OBTAINED DESPITE A GOOD FAITH EFFORT MADE TO OBTAIN THE INFORMATION FROM THE CUSTOMER. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
ARTICLE TITLE: USE OF A SALINE-COUPLED BIPOLAR SEALER OPEN LIVER RESECTION FOR HEPATIC MALIGNANCY: MEDICAL RESOURCE USE AND COSTS DOI: 10.3748/WJG.V22.I46.10189 AIM TO EVALUATE OUTCOMES ASSOCIATED WITH USE OF A SALINE COUPLED BIPOLAR SEALER DURING OPEN PARTIAL LIVER RESECTION. METHODS THIS RETROSPECTIVE ANALYSIS UTILIZED THE UNITED STATES PREMIER¿ INSURANCE CLAIMS DATABASE (2010-2014). PATIENTS WERE SELECTED WITH CODES FOR LIVER MALIGNANCY AND PARTIAL HEPATECTOMY OR LOBECTOMY. CASES WERE DEFINED BY USE THE SALINE-COUPLED BIPOLAR SEALER; CONTROLS HAD NO USE. A PROPENSITY SCORE ALGORITHM WAS USED TO MATCH ONE CASE TO FIVE CONTROLS. A DEVIATION BASED COST MODELING (DBCM) APPROACH PROVIDED AN ESTIMATE OF COST-EFFECTIVENESS. RESULTS ONE HUNDRED AND FORTY-FOUR CASES AND 720 CONTROLS WERE AVAILABLE FOR ANALYSIS. PATIENTS IN THE CASE COHORT RECEIVED FEWER TRANSFUSIONS VS CONTROLS (18.1% VS 29.4%, P = 0.007). IN DBCM, MORE PATIENTS IN THE CASE COHORT EXPERIENCED ¿ON-COURSE¿ HOSPITALIZATIONS (53.5% VS 41.9%, P = 0.009). THE COST CALCULATION SHOWED AN AVERAGE SAVINGS IN TOTAL HOSPITALIZATION COSTS OF $1027 FOR CASES VS CONTROLS. IN MULTIVARIATE ANALYSIS, CASES HAD LOWER ODDS OF RECEIVING A TRANSFUSION (OR = 0.44, 95%CI: 0.27-0.71, P = 0.0008). CONCLUSION USE OF A SALINE-COUPLED BIPOLAR SEALER WAS ASSOCIATED WITH A GREATER PROPORTION OF PATIENTS WITH AN ¿ON COURSE¿ HOSPITALIZATION. THIS RECORD REPRESENTS THE PATIENT THAT EXPERIENCE A HEMORRHAGE/HEMATOMA.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 179322 | UNKNOWN AQUAMANTYS GENERATOR | ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES | GEI | MEDTRONIC ADVANCED ENERGY, LLC | MAE UNK AQM GEN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 66 YR |