FDA Adverse Event Injury Summary report: N

UNKNOWN AQUAMANTYS DEVICE

MDR report key: 6394764 · Received March 10, 2017

Report

Report Number
1226420-2017-00105
Event Type
Injury
Date Received
March 10, 2017
Date of Event
January 1, 2010
Report Date
February 10, 2017
Manufacturer
MEDTRONIC ADVANCED ENERGY, LLC
Product Code
GEI
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NH, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

PRODUCT EVENT: (B)(4). PATIENT INFORMATION INCOMPLETE AND MISSING PATIENT INFORMATION UNABLE TO BE OBTAINED DESPITE A GOOD FAITH EFFORT MADE TO OBTAIN THE INFORMATION FROM THE CUSTOMER.

Additional Manufacturer Narrative · 1

IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 1

ARTICLE TITLE: USE OF A SALINE-COUPLED BIPOLAR SEALER OPEN LIVER RESECTION FOR HEPATIC MALIGNANCY: MEDICAL RESOURCE USE AND COSTS DOI: 10.3748/WJG.V22.I46.10189 AIM TO EVALUATE OUTCOMES ASSOCIATED WITH USE OF A SALINE COUPLED BIPOLAR SEALER DURING OPEN PARTIAL LIVER RESECTION. METHODS THIS RETROSPECTIVE ANALYSIS UTILIZED THE UNITED STATES PREMIER¿ INSURANCE CLAIMS DATABASE (2010-2014). PATIENTS WERE SELECTED WITH CODES FOR LIVER MALIGNANCY AND PARTIAL HEPATECTOMY OR LOBECTOMY. CASES WERE DEFINED BY USE THE SALINE-COUPLED BIPOLAR SEALER; CONTROLS HAD NO USE. A PROPENSITY SCORE ALGORITHM WAS USED TO MATCH ONE CASE TO FIVE CONTROLS. A DEVIATION BASED COST MODELING (DBCM) APPROACH PROVIDED AN ESTIMATE OF COST-EFFECTIVENESS. RESULTS ONE HUNDRED AND FORTY-FOUR CASES AND 720 CONTROLS WERE AVAILABLE FOR ANALYSIS. PATIENTS IN THE CASE COHORT RECEIVED FEWER TRANSFUSIONS VS CONTROLS (18.1% VS 29.4%, P = 0.007). IN DBCM, MORE PATIENTS IN THE CASE COHORT EXPERIENCED ¿ON-COURSE¿ HOSPITALIZATIONS (53.5% VS 41.9%, P = 0.009). THE COST CALCULATION SHOWED AN AVERAGE SAVINGS IN TOTAL HOSPITALIZATION COSTS OF (B)(6) FOR CASES VS CONTROLS. IN MULTIVARIATE ANALYSIS, CASES HAD LOWER ODDS OF RECEIVING A TRANSFUSION (OR = 0.44, 95%CI: 0.27-0.71, P = 0.0008). CONCLUSION USE OF A SALINE-COUPLED BIPOLAR SEALER WAS ASSOCIATED WITH A GREATER PROPORTION OF PATIENTS WITH AN ¿ON COURSE¿ HOSPITALIZATION. THIS RECORD REPRESENTS THE PATIENT THAT EXPERIENCE A HEMORRHAGE/HEMATOMA.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
179317 UNKNOWN AQUAMANTYS DEVICE ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES GEI MEDTRONIC ADVANCED ENERGY, LLC MAE UNK AQM DEV UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1 66 YR