LIGAMAX 5MM ENDO CLIP APPLIER
Report
- Report Number
- 3005075853-2017-00543
- Event Type
- Malfunction
- Date Received
- January 26, 2017
- Report Date
- January 17, 2017
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- FZP
- PMA / PMN Number
- K050344
- Removal / Correction Number
- NA
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AS
- Reporter Occupation
- OTHER
Narratives
(B)(4). ADDITIONAL INFORMATION CONTAINED IN THE JOURNAL ARTICLE RELATING TO PATIENT CONSEQUENCES REFERENCED IN THE ABSTRACT (EVENT DESCRIPTION) THAT COULD NOT BE CORRELATED TO BEING A DIRECT RESULT OF THE USE OF AN ETHICON PRODUCT: NO BLOOD TRANSFUSIONS WERE NECESSARY FOR MYOMECTOMY PROCEDURES. IN 1 CASE, FAILURE OF IDENTIFICATION OF THE UA ON ONE SIDE LED TO UNILATERAL OCCLUSION ONLY. ONE CONVERSION TO LAPAROTOMY WAS NECESSARY BECAUSE OF INTRAOPERATIVE BLEEDING. THIS PATIENT HAD A 15-CM RIGHT CORNUAL MYOMA THAT STILL DEMONSTRATED SUBSTANTIAL VASCULARITY DESPITE BILATERAL UA LIGATION. THIS BLOOD LOSS WAS LIKELY DUE TO A PREDOMINANCE OF THE BLOOD SUPPLY FROM THE OVARIAN ARTERIES. IN THIS CASE, THE MYOMECTOMY WAS COMPLETED EASILY ONCE THE ABDOMEN WAS OPENED. IN (ONE) CASE, INADVERTENT RUPTURE OF THE UA OCCURRED DUE TO APPLICATION OF A PARTIALLY CLOSED CLIP. THE UA WAS GRASPED PROXIMALLY, ENABLING ADDITIONAL CLIPS TO BE APPLIED, HEMOSTASIS WAS SECURED PROMPTLY WITHOUT SEQUELAE, AND THE PROCEDURE WAS COMPLETED LAPAROSCOPICALLY.
IT WAS REPORTED VIA JOURNAL ARTICLE; AUST T, REYFTMANN L, ET AL. ANTERIOR APPROACH TO LAPAROSCOPIC UTERINE ARTERY LIGATION. JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY. 2011; 18(6): 792-795. ABSTRACT: HEREIN IS DESCRIBED AN ANTERIOR APPROACH TO UTERINE ARTERY LIGATION DURING LAPAROSCOPIC MYOMECTOMY AND TOTAL LAPAROSCOPIC HYSTERECTOMY. THE ANTERIOR LEAF OF THE BROAD LIGAMENT IS OPENED AND THE UTERINE ARTERY IS CLIPPED LATERAL TO ITS CROSSING OVER THE URETER. OUTCOME MEASURES WERE COMPLETION OF THE PROCEDURE LAPAROSCOPICALLY AND THE NEED FOR TRANSFUSION POSTOPERATIVELY. THIRTY-EIGHT MYOMECTOMIES AND 28 DIFFICULT TOTAL LAPAROSCOPIC HYSTERECTOMIES (PRIMARILY UTERI WITH LARGE MYOMAS) WERE PERFORMED, WITH 1 CONVERSION TO LAPAROTOMY DURING MYOMECTOMY AND 1 DURING HYSTERECTOMY, AND 1 TRANSFUSION AFTER TOTAL LAPAROSCOPIC HYSTERECTOMY. THE ANTERIOR APPROACH TO UTERINE ARTERY LIGATION IS AN ALTERNATIVE METHOD FOR TREATMENT OF UTERINE ARTERY OCCLUSION DURING LAPAROSCOPIC MYOMECTOMY OR HYSTERECTOMY PERFORMED TO TREAT LARGE MYOMAS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 61335 | LIGAMAX 5MM ENDO CLIP APPLIER | CLIP, IMPLANTABLE | FZP | ETHICON ENDO-SURGERY, LLC. | NA | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |