FDA Adverse Event Malfunction Summary report: N

BLANKETROL

MDR report key: 6266025 · Received January 20, 2017

Report

Report Number
6266025
Event Type
Malfunction
Date Received
January 20, 2017
Date of Event
December 7, 2016
Report Date
December 22, 2016
Manufacturer
CINCINNATI SUB-ZERO PRODUCTS, LLC
Product Code
DWJ
Product Problem
Yes
Report Source
User Facility report
Reporter Location
PA, US
Reporter Occupation
OTHER

Narratives

Description of Event or Problem · 1

PATIENT WITH HYPOXIC ISCHEMIC ENCEPHALOPATHY VS. MECONIUM ASPIRATION SYNDROME ON EXTRACORPOREAL MEMBRANE OXYGENATION (ECMO) DAY 3. REPORTEDLY, RN NOTICED PATIENT TEMPERATURE DECREASING DURING 0440 LAB DRAW. RN INCREASED TEMPERATURE OF RADIANT HEAT SOURCE. AROUND THIS TIME THE INFANT BEGAN HEMORRHAGING FRANK RED BLOOD FROM ENDOTRACHEAL TUBE AND BECAME BRADYCARDIC. CODE INITIATED AT 0543. AT APPROXIMATELY 0600 THE PERFUSIONIST ARRIVED AT BEDSIDE AND NOTED WATER BATH NOT FUNCTIONING. RN ATTEMPTED TO TAKE PATIENT TEMPERATURE. TEMPERATURE WAS UNREADABLE. WATER BATH REMOVED FROM SERVICE. A NEW MACHINE WAS BROUGHT TO THE BEDSIDE. INVESTIGATION ONGOING. AFTER ADDITIONAL INVESTIGATION, IT WAS FOUND THAT A SAFETY MECHANISM SHUT THE WATER BATH OFF WHEN A SCHEDULED GENERATOR TEST WAS BEING PERFORMED THROUGHOUT THE HOSPITAL. REPORTEDLY, LIGHTS ON THE DEVICE REMAINED ON BUT THE WATER PUMP INDICATOR ON THE SIDE STOPPED ROTATING, MEANING WATER WAS NO LONGER BEING CIRCULATED. THERE WERE NO ALARMS THAT SIGNALED THAT THE DEVICE WAS BEING SHUT DOWN. THE SHUTDOWN OF THE DEVICE WENT UNNOTICED FOR APPROXIMATELY 1 HOUR WHICH CAUSED THE PATIENT¿S TEMPERATURE TO DECREASE AFTER WHICH THE ABOVE EVENTS OCCURRED.

Description of Event or Problem · 1

PATIENT WITH HYPOXIC ISCHEMIC ENCEPHALOPATHY VS. MECONIUM ASPIRATION SYNDROME ON EXTRACORPOREAL MEMBRANE OXYGENATION (ECMO) DAY 3. REPORTEDLY, RN NOTICED PATIENT TEMPERATURE DECREASING DURING 0440 LAB DRAW. RN INCREASED TEMPERATURE OF RADIANT HEAT SOURCE. AROUND THIS TIME THE INFANT BEGAN HEMORRHAGING FRANK RED BLOOD FROM ENDOTRACHEAL TUBE AND BECAME BRADYCARDIC. CODE INITIATED AT 0543. AT APPROXIMATELY 0600 THE PERFUSIONIST ARRIVED AT BEDSIDE AND NOTED WATER BATH NOT FUNCTIONING. RN ATTEMPTED TO TAKE PATIENT TEMPERATURE. TEMPERATURE WAS UNREADABLE. WATER BATH REMOVED FROM SERVICE. A NEW MACHINE WAS BROUGHT TO THE BEDSIDE. INVESTIGATION ONGOING.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
51800 BLANKETROL SYSTEM, THERMAL REGULATING DWJ CINCINNATI SUB-ZERO PRODUCTS, LLC

Patients

Seq Age Sex Outcome Treatment
1 0 YR