HANDPIECE MICS
Report
- Report Number
- 3005985723-2016-00447
- Event Type
- Malfunction
- Date Received
- December 22, 2016
- Date of Event
- December 20, 2016
- Report Date
- February 6, 2017
- Manufacturer
- MAKO SURGICAL CORP.
- Product Code
- OLO
- PMA / PMN Number
- K143752
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FL, US
- Reporter Occupation
- OTHER
Narratives
"REPORTED EVENT: IT WAS REPORTED THAT THE HANDLE FELL OFF. ISSUE WAS NOTICED DURING A CASE AND THERE WAS NO CASE DELAY AND NO PATIENT HARM. DEVICE HISTORY REVIEW: REVIEW OF THE DEVICE HISTORY RECORDS INDICATE 50 DEVICES WERE MANUFACTURED UNDER LOT K079W AND 48, INCLUDING 4200646, WERE ACCEPTED INTO FINAL STOCK ON 06/15/16. "VISUAL INSPECTION: VISUAL INSPECTION REVEALED NO PHYSICAL DAMAGE OF UNIT. THE SCREW WAS OUTSIDE OF THE UNIT. DIMENSIONAL INSPECTION: DIMENSIONAL INSPECTION WAS NOT COMPLETED VISUAL INSPECTION CLEARLY SHOWS THE FAILURE OF THE DEVICE. FUNCTIONAL INSPECTION: FUNCTIONAL INSPECTION WAS NOT COMPLETED. REPORTED PROBLEM WAS WITH THE SCREW AND HANDLE. A REVIEW OF COMPLAINTS RELATED TO P/N 209063 SHOWS 5 OTHER COMPLAINT RELATED TO THE FAILURE IN THIS INVESTIGATION (INVESTIGATIONS (B)(4)). ISSUES FOR P/N 209063 WILL BE TRACKED THROUGH TREND REQUEST #1025. CONCLUSIONS: THE SCREW HOLDS THE HANDLE IN PLACE. IF THE SCREW BACKS OUT THEN THE HANDLE CAN FALL. CORRECTIVE ACTION/PREVENTIVE ACTION: NO ACTION IS REQUIRED AT THIS TIME AS THERE IS NO INDICATION TO SUGGEST A PRODUCT NON-CONFORMITY OR UNANTICIPATED HAZARD."
AS PART OF NORMAL COMPLAINT FOLLOW-UP, AN EVALUATION OF THE EVENT HAS BEEN INITIATED BY MAKO SURGICAL. A SUPPLEMENTAL REPORT WILL BE SUBMITTED WHEN ADDITIONAL INFORMATION BECOMES AVAILABLE.
THE SURGEON WAS COMPLETING A TOTAL KNEE ARTHROPLASTY PROCEDURE USING THE ROBOTIC ARM INTERACTIVE ORTHOPEDIC SYSTEM (RIO). DURING BONE PREP, THE GRAY HANDLE FELL OFF THE MICS. THE SMALL SCREW HOLDING IT WAS FOUND ON THE FLOOR. (B)(6) CONTINUED TO USE THE MICS TO SUCCESSFULLY COMPLETE THE CASE.
THE SURGEON WAS COMPLETING A TOTAL KNEE ARTHROPLASTY PROCEDURE USING THE ROBOTIC ARM INTERACTIVE ORTHOPEDIC SYSTEM (RIO). DURING BONE PREP, THE GRAY HANDLE FELL OFF THE MICS. THE SMALL SCREW HOLDING IT WAS FOUND ON THE FLOOR. MARCHAND CONTINUED TO USE THE MICS TO SUCCESSFULLY COMPLETE THE CASE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 850319 | HANDPIECE MICS | STEREOTACTIC DEVICE, ROBOTICS | OLO | MAKO SURGICAL CORP. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Hospitalization |