FDA Adverse Event Summary report: N

RELIANCE 444 WASHER

MDR report key: 6175230 · Received December 15, 2016

Report

Report Number
9680353-2016-00124
Date Received
December 15, 2016
Date of Event
November 14, 2016
Report Date
December 14, 2016
Manufacturer
STERIS CANADA CORPORATION
Product Code
MEC
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

THE USER FACILITY STATED THAT ALL INSTRUMENTS PROCESSED IN THESE CYCLES WERE VISIBLY INSPECTED AND STERILIZED PRIOR TO USE IN PATIENT PROCEDURES. THE STERIS RELIANCE 444 WASHER/DISINFECTOR OPERATOR MANUAL STATES ON PAGE I, "STERIS DOES NOT INTEND, RECOMMEND NOR REPRESENT IN ANY WAY THAT THIS RELIANCE 444 SINGLE-CHAMBER WASHER/DISINFECTOR BE USED FOR THE TERMINAL DISINFECTION OR STERILIZATION OF ANY REGULATED MEDICAL DEVICE. RELIANCE 444 SINGLE- CHAMBER WASHER/ DISINFECTORS ARE INTENDED ONLY TO PERFORM AN INITIAL STEP IN THE PROCESSING OF SOILED, REUSABLE MEDICAL DEVICES. IF MEDICAL DEVICES WILL BE CONTACTING BLOOD OR COMPROMISED TISSUES, SUCH DEVICES MUST BE TERMINALLY PROCESSED IN ACCORDANCE WITH DEVICE MANUFACTURER'S INSTRUCTIONS AND/OR GOOD HOSPITAL PRACTICES BEFORE EACH USE IN HUMAN PATIENTS." THE STERIS OPERATOR MANUAL ALSO STATES ON PAGE 4-12, "GOOD HOSPITAL PRACTICE DICTATES THAT ALL INSTRUMENTS BE INSPECTED FOR VISIBLE DEBRIS AFTER PROCESSING IN THE AMSCO RELIANCE 444 SINGLE-CHAMBER WASHER/DISINFECTOR - INTERNATIONAL. ANY INSTRUMENT WITH VISIBLE DEBRIS MUST BE REWASHED UNTIL CLEAN AND FREE OF VISIBLE DEBRIS PRIOR TO TERMINAL PROCESSING. FAILURE TO REPROCESS UNTIL ALL VISIBLE DEBRIS HAVE BEEN REMOVED MAY IMPEDE THE TERMINAL PROCESSING." A STERIS SERVICE TECHNICIAN ARRIVED ON-SITE AND COULD NOT DUPLICATE THE REPORTED EVENT. THE RELIANCE 444 WASHERS AND KNIGHT CHEMICAL DOSING SYSTEMS WERE OPERATING PROPERLY. NO ADDITIONAL ISSUES HAVE BEEN REPORTED. A STERIS ACCOUNT MANAGER PROVIDED IN-SERVICE TRAINING ON PROPER USE AND OPERATION OF THE WASHER AND KNIGHT CHEMICAL DOSING SYSTEMS. NO ADDITIONAL ISSUES HAVE BEEN REPORTED.

Description of Event or Problem · 1

THE USER FACILITY REPORTED THAT FOUR KNIGHT CHEMICAL DOSING SYSTEMS WERE NOT PROPERLY DISPENSING DETERGENT WHEN RUNNING CYCLES WITHIN THEIR RELIANCE 444 WASHERS/DISINFECTORS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
825827 RELIANCE 444 WASHER WASHER MEC STERIS CANADA CORPORATION

Patients

Seq Age Sex Outcome Treatment
1 Other