FDA Adverse Event Malfunction Summary report: N

ANGIODYNAMICS

MDR report key: 6142761 · Received December 2, 2016

Report

Report Number
1317056-2016-00181
Event Type
Malfunction
Date Received
December 2, 2016
Date of Event
November 2, 2016
Report Date
November 9, 2016
Manufacturer
ANGIODYNAMICS
Product Code
DTL
UDI-DI
H965700550091
PMA / PMN Number
K842829
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

A REVIEW OF THE DEVICE HISTORY RECORDS WAS PERFORMED FOR THE REPORTED PACKAGING LOT FOR ANY DEVIATIONS RELATED TO THE REPORTED DEFECT OF THE COMPLAINT. THE REVIEW CONFIRMS THAT THE LOT MET ALL MATERIAL, ASSEMBLY AND PERFORMANCE SPECIFICATIONS. THE ANGIODYNAMICS (B)(6) 2016 COMPLAINT REPORT WAS REVIEWED FOR THE STOPCOCKS PRODUCT FAMILY AND THE FAILURE MODE,"HOLE IN POUCH." NO ADVERSE TRENDS WERE IDENTIFIED. THE RETURNED SAMPLE WAS VISUALLY INSPECTED AND THE HOLE IN THE POUCH WAS CONFIRMED. THE ROOT CAUSE OF THE HOLE IS THE HANDLE FROM THE STOPCOCK PRESSES OUTWARD AGAINST THE TYVEK. AS PART OF THE RECEIVING PROCESS AT (B)(4), ALL POUCHED PRODUCTS ARE REMOVED FROM THEIR INNER BOXES AND A NIPRO LABEL (IN (B)(6) IS APPLIED TO EACH POUCH. ADDITIONAL HANDLING MAY OCCUR IF PRODUCT IS 100% VISUALLY INSPECTED. THE POUCHED PRODUCT IS THEN RE-BOXED INTO THE INNER BOX BY THE NIPRO WAREHOUSE EMPLOYEES. THE HOLE IN THE TYVEK WAS LIKELY CAUSED BY THE HANDLE OF A STOPCOCK IN THE POUCH, HOWEVER, WHAT CAUSED THE HANDLE TO BE PUSHED AGAINST THE TYVEK IN A MANNER THAT RESULTED IN A HOLE CANNOT BE DETERMINED. POTENTIAL CONTRIBUTING FACTORS INCLUDE: HANDLING OF THE POUCHES AS THEY ARE PLACED IN THE INNER BOXES. HANDLING DURING TRANSIT TO NIPRO WAREHOUSE. HANDLING DURING NIPRO LABELING/INSPECTION AND RE-BOXING PROCESS. ALL POUCHES ARE 100% INSPECTED PER ANGIODYNAMICS PROCEDURES DURING THE SEALING AND FINAL BOX PROCESSES. THE DIRECTIONS FOR USE (DFU) PACKAGED WITH THE KITS CONTAIN THE FOLLOWING WARNING: "CONTENTS SUPPLIED STERILE USING AN ETHYLENE OXIDE (EO) PROCESS. DO NOT USE IF STERILE BARRIER IS DAMAGED." (B)(4).

Description of Event or Problem · 1

AS REPORTED BY ANGIODYNAMICS' DISTRIBUTOR IN (B)(6), IN THE DISTRIBUTOR'S WAREHOUSE A SMALL HOLE WAS FOUND IN THE TYVEK PORTION OF A STOPCOCK POUCH, BREACHING THE STERILITY. THE DEVICE HAD NOT BEEN PROVIDED TO A HOSPITAL, AND WAS RETURNED TO ANGIODYNAMICS FOR EVALUATION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
791174 ANGIODYNAMICS STOPCOCK HIGH PRESSURE DTL ANGIODYNAMICS 5063296 H965700550091

Patients

Seq Age Sex Outcome Treatment
1