FDA Adverse Event Malfunction Summary report: N

T25 STARDRIVE SHAFT F/MATRIX CANNULATED/LONG

MDR report key: 6118477 · Received November 21, 2016

Report

Report Number
1719045-2016-10838
Event Type
Malfunction
Date Received
November 21, 2016
Report Date
September 27, 2016
Manufacturer
SYNTHES MONUMENT
Product Code
HXX
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
TX, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. ADDITIONAL NARRATIVE: EVENT DATE: UNKNOWN. DEVICE IS AN INSTRUMENT AND IS NOT IMPLANTED/EXPLANTED. MANUFACTURING LOCATION: SUPPLIER-UNIVERSAL PUNCH, PACKAGED BY: (B)(4), MANUFACTURING DATE: 01-SEP-2015, PART #: 03.632.073, LOT#: 7965064 (NON-STERILE) - T25 STARDRIVE SHAFT F/MATRIX CANNULATED/LONG. QUANTITY (B)(4). NO NCRS WERE GENERATED DURING PRODUCTION. REVIEW OF THE DEVICE HISTORY RECORD(S) SHOWED THAT THERE WERE NO ISSUES DURING THE MANUFACTURE OF THE PRODUCT THAT WOULD CONTRIBUTE TO THIS COMPLAINT CONDITION. A VISUAL INSPECTION AND DRAWING REVIEW WERE PERFORMED AS PART OF THIS INVESTIGATION. THE COMPLAINT IS CONFIRMED. THE HANDLE OF THE GRAFT PUSHER (CANCELLOUS BONE PUSHER) (394.572, LOT # 4484934) WAS FOUND TO BE BROKEN AT THE DISTAL END. THE DEVICE SHOWS SURFACE SCRATCHES AND WEAR CONSISTENT WITH 14 YEARS OF USE. THE SCREWDRIVER SHAFT STARDRIVE T25, LONG (03.632.401, LOT #9404572) WAS FOUND TO BE BROKEN AT THE DISTAL TIP. THE DEVICE IS OTHERWISE IN GOOD CONDITION WITH MINIMAL SURFACE WEAR. THE SCREWDRIVER SHAFT T25, CANNULATED LONG (03.632.073, LOT #7965064) WAS FOUND TO BE BROKEN AT THE DISTAL TIP. THE DEVICE IS OTHERWISE IN GOOD CONDITION WITH MINIMAL SURFACE WEAR. DRAWINGS FOR GRAFT PUSHER 394.572, SCREWDRIVER SHAFT T25, CANNULATED, 03.632.073, AND SCREWDRIVER SHAFT STARDRIVE T25, LONG, 03.632.401 WERE REVIEWED DURING INVESTIGATION. THE DESIGN HISTORY WAS NOT FOUND TO IMPACT THE COMPLAINT CONDITION. DURING THE INVESTIGATION NO PRODUCT DESIGN ISSUES OR DISCREPANCIES WERE OBSERVED THAT MAY HAVE CONTRIBUTED TO THE COMPLAINT CONDITION. THE RETURNED PARTS WERE DETERMINED TO BE SUITABLE FOR THE INTENDED USE WHEN EMPLOYED. NO DEFINITIVE ROOT CAUSE WAS ABLE TO BE DETERMINED. THE GRAFT PUSHER (CANCELLOUS BONE PUSHER) (394.572, LOT # 4484934) WAS IN USE FOR APPROXIMATELY 14 YEARS. THE ROOT CAUSE OF THE BROKEN HANDLE IS MOST LIKELY DUE TO WEAR AND TEAR ASSOCIATED WITH CONSISTENT USE OVER THE 14 YEAR TIMEFRAME. THE SCREWDRIVER SHAFT STARDRIVE T25, LONG (03.632.401, LOT #9404572). THE ROOT CAUSE IS MOST LIKELY RELATED TO APPLICATION OF EXCESSIVE TORQUE ON THE DRIVER. THE SCREWDRIVER SHAFT T25, CANNULATED LONG (03.632.073, LOT #7965064). THE ROOT CAUSE IS MOST LIKELY RELATED TO APPLICATION OF EXCESSIVE TORQUE ON THE DRIVER. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE TIPS OF BOTH THE STRAIGHT TIP T25 DRIVER-LONG AND T25 STARDRIVE SHAFT FOR MATRIX CANNULATED/LONG ARE STRIPPED AND THE WOODEN HANDLE OF A GRAFT PUSHER 8MM IS FALLING APART. THE PIECES ARE STILL ATTACHED TO THE HANDLE. THE ISSUES WERE DISCOVERED AFTER THE INSTRUMENTS WERE STERILIZED. NO ISSUES WITH THE DEVICES PRIOR TO DISCOVERY. NO CASE OR PATIENT INVOLVEMENT. UPON COMPLETION OF THE INVESTIGATION, IT WAS FOUND THAT THE DISTAL TIP WAS BROKEN. THIS COMPLAINT IS FOR ONE T25 STARDRIVE SHAFT F/MATRIX CANNULATED/LONG. THIS IS REPORT NUMBER 2 OF 3 FOR COMPLAINT (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
769605 T25 STARDRIVE SHAFT F/MATRIX CANNULATED/LONG SCREWDRIVERS HXX SYNTHES MONUMENT 7965064

Patients

Seq Age Sex Outcome Treatment
1