FDA Adverse Event Malfunction Summary report: N

3.0 RIO® ROBOTIC ARM - MICS

MDR report key: 6116933 · Received November 21, 2016

Report

Report Number
3005985723-2016-00393
Event Type
Malfunction
Date Received
November 21, 2016
Date of Event
November 16, 2016
Report Date
February 13, 2017
Manufacturer
MAKO SURGICAL CORP.
Product Code
OLO
PMA / PMN Number
K141989
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

AS PART OF NORMAL COMPLAINT FOLLOW-UP, AN EVALUATION OF THE EVENT HAS BEEN INITIATED BY MAKO SURGICAL. A SUPPLEMENTAL REPORT WILL BE SUBMITTED WHEN ADDITIONAL INFORMATION BECOMES AVAILABLE.

Additional Manufacturer Narrative · 1

REPORTED EVENT: AN EVENT REGARDING CONNECTION ERROR INVOLVING 3.0 RIO ROBOTIC ARM - MICS, CATALOG: 209999 WAS REPORTED. METHOD & RESULTS: DEVICE HISTORY REVIEW: A REVIEW OF THE DHR ASSOCIATED WITH RIO 325 FOUND QUALITY INSPECTION PROCEDURES SUCCESSFULLY PASSED. COMPLAINT HISTORY: BASED ON THE DEVICE IDENTIFICATION (PN (B)(4)), SERIAL # (B)(4), THE COMPLAINT DATABASES WERE REVIEWED FROM 2011 TO PRESENT FOR SIMILAR REPORTED EVENTS REGARDING A CONNECTION ERROR. THERE WAS ONE OTHER REPORTED EVENT, PR1222981. CONCLUSION: THE LOG DATA FROM THE CASE WAS REVIEWED. BASED ON THE COLLECTED DATA, IT WAS CONFIRMED THAT THERE WAS A COMMUNICATION ERROR. IT IS POSSIBLE THAT THE ETHERNET CABLE OR FIBER OPTIC CABLES FROM THE GUIDANCE TO THE ROBOT MAY HAVE BEEN DISCONNECTED DURING MOVEMENT OR DIRTY FIBERS. THERE IS NO ASSOCIATED GSP TICKET WITH THE EVENT, HOWEVER THEY WERE ABLE TO REBOOT AND RE-REGISTER THE ROBOT, THUS RESTORING COMMUNICATION. IT IS RECOMMENDED THAT IF THE PROBLEM PERSISTS TO CALL FIELD SERVICE.

Description of Event or Problem · 1

THE SURGEON WAS COMPLETING A TOTAL HIP ARTHROPLASTY PROCEDURE WHEN HE EXPERIENCED A CONNECTION ERROR WHEN ENTERING INTO THE REAMING PAGE. A HARD SHUT DOWN AND RE-HOME/REGISTER OF THE ROBOT WAS DONE, HOWEVER THE SURGEON OPTED TO COMPLETING THE CASE MANUALLY.

Description of Event or Problem · 1

THE SURGEON WAS COMPLETING A TOTAL HIP ARTHROPLASTY PROCEDURE WHEN HE EXPERIENCED A CONNECTION ERROR WHEN ENTERING INO THE REAMING PAGE. A HARD SHUT DOWN AND RE-HOME/REGISTER OF THE ROBOT WAS DONE, HOWEVER THE SURGEON OPTED TO COMPLETING THE CASE MANUALLY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
768575 3.0 RIO® ROBOTIC ARM - MICS STEREOTACTIC DEVICE, ROBOTICS OLO MAKO SURGICAL CORP.

Patients

Seq Age Sex Outcome Treatment
1 Hospitalization