FDA Adverse Event Death Summary report: N

ONYX

MDR report key: 6074001 · Received November 2, 2016

Report

Report Number
2029214-2016-00967
Event Type
Death
Date Received
November 2, 2016
Report Date
October 5, 2016
Manufacturer
COVIDIEN (IRVINE)
Product Code
MFE
PMA / PMN Number
P030004
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
CH
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

PLEASE REFERENCE MDR NUMBERS: 2029214-2016-00964, 2029214-2016-00965, AND 2029214-2016-00968 FOR THE OTHER MDRS SUBMITTED FROM THIS LITERATURE REVIEW.

Additional Manufacturer Narrative · 1

CITATION: C. LI · X. YANG · Y. LI · C. JIANG · Z. WU. ENDOVASCULAR TREATMENT OF INTRACRANIAL DURAL ARTERIOVENOUS FISTULAS PRESENTING WITH INTRACRANIAL HEMORRHAGE IN 46 CONSECUTIVE PATIENTS: WITH EMPHASIS ON TRANSARTERIAL EMBOLIZATION WITH ONYX. CLIN NEURORADIOL (2016) 26:301¿308 DOI 10.1007/S00062-014-0362-Y. PUBLISHED ONLINE: 13 DECEMBER 2014 THERE IS LIMITED INFORMATION ABOUT THE DEVICE AND/OR THE PATIENT, INCLUDING ANY PROCEDURAL DETAILS. ATTEMPTS WERE MADE TO OBTAIN ADDITIONAL INFORMATION. HOWEVER, NO ADDITIONAL INFORMATION WAS PROVIDED. THE ONYX IFU ADVISES: "STOP INJECTION IF INCREASED RESISTANCE TO THE ONYX¿ LES INJECTION IS OBSERVED. IF INCREASED RESISTANCE OCCURS, DETERMINE THE CAUSE (E.G., ONYX¿ LES OCCLUSION IN CATHETER LUMEN) AND REPLACE THE CATHETER. DO NOT ATTEMPT TO CLEAR OR OVERCOME RESISTANCE BY APPLYING INCREASED INJECTION PRESSURE, AS USE OF EXCESSIVE PRESSURE MAY RESULT IN CATHETER RUPTURE AND EMBOLIZATION OF UNINTENDED AREAS."

Description of Event or Problem · 1

MEDTRONIC RECEIVED INFORMATION THROUGH LITERATURE REVIEW THAT ONE PATIENT ENCOUNTERED MIGRATION OF THE ONYX EMBOLUS INTO THE POSTERIOR INFERIOR CEREBELLAR ARTERY (PICA) AND DIED OF MULTIPLE ORGAN FAILURE 10 DAYS AFTER EVT. THIS WAS A RESULT OF COMPLICATIONS OF ONYX EMBOLUS INTO THE POSTERIOR INFERIOR CEREBELLAR ARTERY. THE PURPOSE OF THE STUDY DISCUSSED IN THE ARTICLE WAS TO EVALUATE THE EFFECTIVENESS AND SAFETY AS WELL AS THE CLINICAL AND ANGIOGRAPHIC RESULTS OF THE ENDOVASCULAR TREATMENT (EVT) FOR PATIENTS WITH HEMORRHAGIC DURAL ARTERIOBENOUS FISTULAS (DAVFS). FROM 2009 TO NOVEMBER 2014, 46 CONSECUTIVE PATIENTS WITH HEMORRHAGIC INTRACRANIAL DAVFS WERE ENROLLED. THE CLINICAL AND ANGIOGRAPHIC DATA WERE REVIEWED AND EVALUATED. IN THIS RETROSPECTIVE STUDY, ANGIOGRAPHIC AND CLINICAL OUTCOMES OF THE 46 PATIENTS WITH HEMORRHAGIC DAVFS TREATED WITH EVT WAS REVIEWED. THE AUTHORS CONCLUDED THAT EVT WAS EFFECTIVE AND SAFE IN THE MODERN MANAGEMENT OF RUPTURED INTRACRANIAL DAVFS, WITH COMPLETE CURE IN MOST LESIONS. CLINICAL OUTCOMES WERE GOOD DESPITE PATIENTS PRESENTING WITH INTRACRANIAL HEMORRHAGE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
724205 ONYX AGENT, INJECTABLE, EMBOLIC MFE COVIDIEN (IRVINE) UNK UNK

Patients

Seq Age Sex Outcome Treatment
1 Death