THERMOCOOL® SMARTTOUCH® BI-DIRECTIONAL NAVIGATION CATHETER
Doing adverse event research by hand?
The Research Assistant searches MAUDE for you, groups reports by failure mode, and cites every record.
Free to try · every answer cites its records
Report
- Report Number
- 9673241-2016-00737
- Event Type
- Injury
- Date Received
- October 25, 2016
- Date of Event
- October 4, 2016
- Report Date
- October 4, 2016
- Manufacturer
- BIOSENSE WEBSTER, INC. (JUAREZ)
- Product Code
- LPB
- UDI-DI
- 10846835009200
- PMA / PMN Number
- P030031/S053
- Removal / Correction Number
- NA
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NM, US
- Reporter Occupation
- OTHER
Narratives
SINCE THE PRODUCT WAS NOT RETURNED FOR ANALYSIS, NO PRODUCT FAILURE ANALYSIS CAN BE CONDUCTED AND NO DETERMINATION OF POSSIBLE CONTRIBUTING FACTORS COULD BE MADE. AS SUCH, THE INVESTIGATION WILL BE CLOSED. IF THE COMPLAINT DEVICE IS RECEIVED IN THE FUTURE WE WILL REOPEN THE COMPLAINT AND PERFORM THE INVESTIGATION AS APPROPRIATE. THE DEVICE HISTORY RECORD (DHR) WAS REVIEWED AND NO ANOMALIES WERE FOUND RELATED TO THIS COMPLAINT. IN ADDITION, THE DHR REVIEW VERIFIES THAT THE DEVICE WAS MANUFACTURED IN ACCORDANCE WITH DOCUMENTED SPECIFICATION AND PROCEDURES. MANUFACTURER'S REF. NO: (B)(4).
IT WAS REPORTED THAT A (B)(6) MALE PATIENT UNDERWENT AN ABLATION PROCEDURE FOR IDIOPATHIC VENTRICULAR TACHYCARDIA WITH A THERMOCOOL® SMARTTOUCH® BI-DIRECTIONAL NAVIGATION CATHETER AND SUFFERED A CARDIAC TAMPONADE REQUIRING PERICARDIOCENTESIS. AFTER THE CASE WAS COMPLETED AND THE CATHETERS AND SHEATH WERE REMOVED, THE PATIENT BECAME DIAPHORETIC AND HYPOTENSIVE. TAMPONADE WAS CONFIRMED VIA ECHOCARDIOGRAM. PERICARDIOCENTESIS YIELDED AN UNKNOWN AMOUNT OF FLUID. PATIENT WAS REPORTED TO BE IN STABLE CONDITION AT THE TIME OF COMPLAINT REPORT. PATIENT REQUIRED AN OVERNIGHT HOSPITAL STAY FOR OBSERVATION. PATIENT FULLY RECOVERED WITH NO RESIDUAL EFFECTS. MEDICAL HISTORY INCLUDES: CONGESTIVE HEART FAILURE, VENTRICULAR BIGEMINY, ESSENTIAL HYPERTENSION, AND LOWER EXTREMITY EDEMA. LABS INCLUDE: CREATININE 1.49, PLATELETS 254, POTASSIUM 4, HEMOGLOBIN 15.3, HEMATOCRIT 45.2, AND GLUCOSE 123. FACTORS THAT MAY HAVE CONTRIBUTED TO THE ADVERSE EVENT INCLUDE A DIFFICULT TRANSSEPTAL PUNCTURE. PHYSICIAN¿S OPINION REGARDING THE CAUSE OF THE ADVERSE EVENT IS THAT IT WAS PROCEDURE-RELATED, AS IT INVOLVED TRANSSEPTAL PUNCTURE. IT WAS NOTED THAT THE INJURY MAY HAVE OCCURRED AFTER A DIFFICULT TRANSSEPTAL PUNCTURE OR PRIOR TO THE CATHETER ENTERING THE VENTRICLE. TRANSSEPTAL PUNCTURE WAS PERFORMED WITH A ST. JUDE MEDICAL BRK 98CM NEEDLE. SHEATH USED WAS A MOBICATH 8.5 FRENCH. GENERATOR PARAMETERS AT THE TIME OF INJURY INCLUDED: POWER CONTROL MODE AT 40 WATTS WITH TEMPERATURE WARNING AT 40°C AND CUT-OFF AT 42°C. IT WAS REPORTED THAT NOTHING UNUSUAL WAS NOTED DURING ABLATION. TOTAL RADIOFREQUENCY TIME WAS 9 MINUTES AND 22 SECONDS. THERE IS NO INFORMATION REGARDING LAST ABLATION CYCLE TIME AT THE SITE OF INJURY. IRRIGATED CATHETER FLOW SETTING WAS 30ML/MIN WHEN ABLATING AT 40 WATTS. PATIENT RECEIVED ANTICOAGULANT DURING THE PROCEDURE WITH ACTIVATED CLOTTING TIMES MAINTAINED BETWEEN 300-350 SECONDS. THERE WERE NO ERROR MESSAGES ON ANY BWI EQUIPMENT DURING THE PROCEDURE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 704212 | THERMOCOOL® SMARTTOUCH® BI-DIRECTIONAL NAVIGATION CATHETER | CARDIAC ABLATION PERCUTANEOUS CATHETER | LPB | BIOSENSE WEBSTER, INC. (JUAREZ) | D-1327-05-S | 17553106M | 10846835009200 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 74 YR | Hospitalization| L| R |