FDA Adverse Event Malfunction Summary report: N

FLEXI-SEAL FMS KIT

MDR report key: 6048163 · Received October 21, 2016

Report

Report Number
1049092-2016-00445
Event Type
Malfunction
Date Received
October 21, 2016
Report Date
October 7, 2016
Manufacturer
CONVATEC INC.
Product Code
KNT
PMA / PMN Number
K032734
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IT
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

BASED ON THE AVAILABLE INFORMATION, THIS EVENT IS DEEMED TO BE A PRODUCT MALFUNCTION. ADDITIONAL DETAILS HAVE BEEN REQUESTED BUT HAVE NOT BEEN RECEIVED TO DATE. WHEN ADDITIONAL INFORMATION BECOMES AVAILABLE, A FOLLOW-UP REPORT WILL BE SUBMITTED. (B)(4).

Additional Manufacturer Narrative · 1

A PREVIOUS ROOT CAUSE INVESTIGATION AND CAUSALITY ASSESSMENT FOR THIS KNOWN COMPLAINT ISSUE HAS BEEN CONDUCTED. RETENTION SAMPLES FOR FLEXI-SEAL STANDARD FMS ((B)(4)) WERE EVALUATED IN A PREVIOUS ROOT CAUSE INVESTIGATION. THE MANUFACTURING PROCESS, QUALITY INSPECTION, PACKAGING PROCESS, AND QUALITY CONTROL RECORDS WERE REVIEWED. SIMULATION TESTING INCLUDING ADHESION/TENSILE STRENGTH TESTING IN THE REVERSE DIRECTION WAS PERFORMED. THE APPEARANCE OF THE BALLOON, CATHETER BODY AND VALVE FUNCTION WERE NORMAL. NO BROKEN TUBE AND SEPARATIONS AT JOINT WERE FOUND. THE INVESTIGATION OF THE RETENTION SAMPLES FOUND THREE PROBABLE ROOT CAUSES FOR THE REPORTED MALFUNCTION AND THEY ARE AS FOLLOWS: LUMEN/SILICONE TUBE MATERIAL STRENGTH/THICKNESS. EXCESSIVE FORCE-PULL SYRINGE BEFORE COMPLETELY TWISTING LUER CONNECTION TO REMOVE THE SYRINGE AFTER USE. EXCESSIVE FORCE-ROTATIONAL FORCE WHEN ATTACHING/REMOVING SYRINGE DURING USES. THE MOST PROBABLE ROOT CAUSE WAS THE EXTERNAL FORCE WHICH EXCEEDS THE LUMEN JOINT STRENGTH OF AROUND 1.25~2.58 KG FORCE. THE INVESTIGATION DID NOT IDENTIFY ANY DEFECTS SPECIFIC TO THE LUMEN, ADHESIVE, PROCESSING, SHELF LIFE OR JHT. NO NON-CONFORMANCES FROM THE MANUFACTURING PROCESS WERE IDENTIFIED. THE RISK DOCUMENTATION ALIGNS WITH THE POST MARKET FIELD DATA FOR OCCURRENCE OF THE BROKEN LUMEN, THEREFORE, THE DESIGN IS PERFORMING AS INTENDED. ALL THE TESTING AVAILABLE SUPPORTS THAT THE PRODUCT CAN WITHSTAND A REASONABLE AMOUNT OF FORCE 1.25~2.58 KG FORCE, I.E., 12.3 N - 25.3 N. THE MALFUNCTION MAY OCCUR WHEN THE FORCE IS COMBINED WITH INCOMPLETE DETACHMENT OF THE SYRINGE FROM THE LUER LOCK. PRODUCT MONITORING REVIEWS WILL MONITOR FOR PRODUCT TRENDS IF THIS ISSUE WERE TO REOCCUR. THIS EVALUATION WILL BE CLOSED. NO ADDITIONAL PATIENT/EVENT DETAILS HAVE BEEN PROVIDED TO DATE. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, A FOLLOW-UP REPORT WILL BE SUBMITTED. (B)(4).

Description of Event or Problem · 1

COMPLAINT RECEIVED REPORTING AN INFLATION PORT ISSUE WITH THE DEVICE. REPORTER STATED "ONCE OPENED THE DEVICE THE CUSTOMER REALIZED THAT WAS MISSING THE IRRIGATION PORT." THE DEVICE WAS NO USED. NO FURTHER INFORMATION WAS PROVIDED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
698566 FLEXI-SEAL FMS KIT TUBES, GASTROINTESTINAL (AND ACCESSORIES) KNT CONVATEC INC. 411100 16FM0001

Patients

Seq Age Sex Outcome Treatment
1